Accuracy of digital templating of uncemented total hip arthroplasty at a certified arthroplasty center: a retrospective comparative study

INTRODUCTION: To investigate the accuracy of preoperative digital templating for total hip arthroplasty (THA) at a certified arthroplasty center (EndoCert EPZmax). MATERIALS AND METHODS: In a retrospective study design, we analysed 620 uncemented primary THAs for templating accuracy by comparing the...

Descripción completa

Detalles Bibliográficos
Autores principales: Dammerer, D., Keiler, A., Herrnegger, S., Putzer, D., Strasser, S., Liebensteiner, M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9474525/
https://www.ncbi.nlm.nih.gov/pubmed/33725193
http://dx.doi.org/10.1007/s00402-021-03836-w
_version_ 1784789738441408512
author Dammerer, D.
Keiler, A.
Herrnegger, S.
Putzer, D.
Strasser, S.
Liebensteiner, M.
author_facet Dammerer, D.
Keiler, A.
Herrnegger, S.
Putzer, D.
Strasser, S.
Liebensteiner, M.
author_sort Dammerer, D.
collection PubMed
description INTRODUCTION: To investigate the accuracy of preoperative digital templating for total hip arthroplasty (THA) at a certified arthroplasty center (EndoCert EPZmax). MATERIALS AND METHODS: In a retrospective study design, we analysed 620 uncemented primary THAs for templating accuracy by comparing the preoperatively planned THA component size and the implanted size as documented by the surgeon. Templating was determined to be a) exact if the planned and the implanted component were the same size and b) accurate if they were exact ± one size. Moreover, we investigated factors that potentially influence templating accuracy: overweight and obesity (WHO criteria), sex, implant design, surgeon experience, preoperative diagnosis. Digital templating was done with MediCAD software. The Mann–Whitney U test and the Kruskal–Wallis test were used for statistical analysis. RESULTS: Templating was exact in 52% of stems and 51% of cups and was accurate in 90% of the stems and 85% of the cups. Regarding the factors potentially influencing templating accuracy, the type of cup implant had a significant influence (p = 0.016). Moreover, greater accuracy of stem templating was achieved in female patients (p = 0.004). No such effect was determined for the other factors investigated. CONCLUSIONS: We conclude that preoperative 2D templating is accurate in 90% of the stems and 85% of the cups. Greater accuracy may be achieved in female patients. In addition to gender, the type of implant used may influence planning accuracy as well. Surgeon experience, BMI and preoperative diagnosis did not influence templating accuracy. LEVEL OF EVIDENCE: Level III (retrospective comparative study with prospective cohort).
format Online
Article
Text
id pubmed-9474525
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-94745252022-09-16 Accuracy of digital templating of uncemented total hip arthroplasty at a certified arthroplasty center: a retrospective comparative study Dammerer, D. Keiler, A. Herrnegger, S. Putzer, D. Strasser, S. Liebensteiner, M. Arch Orthop Trauma Surg Orthopaedic Surgery INTRODUCTION: To investigate the accuracy of preoperative digital templating for total hip arthroplasty (THA) at a certified arthroplasty center (EndoCert EPZmax). MATERIALS AND METHODS: In a retrospective study design, we analysed 620 uncemented primary THAs for templating accuracy by comparing the preoperatively planned THA component size and the implanted size as documented by the surgeon. Templating was determined to be a) exact if the planned and the implanted component were the same size and b) accurate if they were exact ± one size. Moreover, we investigated factors that potentially influence templating accuracy: overweight and obesity (WHO criteria), sex, implant design, surgeon experience, preoperative diagnosis. Digital templating was done with MediCAD software. The Mann–Whitney U test and the Kruskal–Wallis test were used for statistical analysis. RESULTS: Templating was exact in 52% of stems and 51% of cups and was accurate in 90% of the stems and 85% of the cups. Regarding the factors potentially influencing templating accuracy, the type of cup implant had a significant influence (p = 0.016). Moreover, greater accuracy of stem templating was achieved in female patients (p = 0.004). No such effect was determined for the other factors investigated. CONCLUSIONS: We conclude that preoperative 2D templating is accurate in 90% of the stems and 85% of the cups. Greater accuracy may be achieved in female patients. In addition to gender, the type of implant used may influence planning accuracy as well. Surgeon experience, BMI and preoperative diagnosis did not influence templating accuracy. LEVEL OF EVIDENCE: Level III (retrospective comparative study with prospective cohort). Springer Berlin Heidelberg 2021-03-16 2022 /pmc/articles/PMC9474525/ /pubmed/33725193 http://dx.doi.org/10.1007/s00402-021-03836-w Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Orthopaedic Surgery
Dammerer, D.
Keiler, A.
Herrnegger, S.
Putzer, D.
Strasser, S.
Liebensteiner, M.
Accuracy of digital templating of uncemented total hip arthroplasty at a certified arthroplasty center: a retrospective comparative study
title Accuracy of digital templating of uncemented total hip arthroplasty at a certified arthroplasty center: a retrospective comparative study
title_full Accuracy of digital templating of uncemented total hip arthroplasty at a certified arthroplasty center: a retrospective comparative study
title_fullStr Accuracy of digital templating of uncemented total hip arthroplasty at a certified arthroplasty center: a retrospective comparative study
title_full_unstemmed Accuracy of digital templating of uncemented total hip arthroplasty at a certified arthroplasty center: a retrospective comparative study
title_short Accuracy of digital templating of uncemented total hip arthroplasty at a certified arthroplasty center: a retrospective comparative study
title_sort accuracy of digital templating of uncemented total hip arthroplasty at a certified arthroplasty center: a retrospective comparative study
topic Orthopaedic Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9474525/
https://www.ncbi.nlm.nih.gov/pubmed/33725193
http://dx.doi.org/10.1007/s00402-021-03836-w
work_keys_str_mv AT dammererd accuracyofdigitaltemplatingofuncementedtotalhiparthroplastyatacertifiedarthroplastycenteraretrospectivecomparativestudy
AT keilera accuracyofdigitaltemplatingofuncementedtotalhiparthroplastyatacertifiedarthroplastycenteraretrospectivecomparativestudy
AT herrneggers accuracyofdigitaltemplatingofuncementedtotalhiparthroplastyatacertifiedarthroplastycenteraretrospectivecomparativestudy
AT putzerd accuracyofdigitaltemplatingofuncementedtotalhiparthroplastyatacertifiedarthroplastycenteraretrospectivecomparativestudy
AT strassers accuracyofdigitaltemplatingofuncementedtotalhiparthroplastyatacertifiedarthroplastycenteraretrospectivecomparativestudy
AT liebensteinerm accuracyofdigitaltemplatingofuncementedtotalhiparthroplastyatacertifiedarthroplastycenteraretrospectivecomparativestudy