Cargando…

Visual and instrumental coverage error of two dental shade guides: an in vivo study

OBJECTIVES: This study aims to evaluate in vivo the color agreement between natural teeth and dental shade guides by means of visual and instrumental coverage error ([Formula: see text] ) index. MATERIALS AND METHODS: The color of the middle third of 735 incisors was visually determined by two evalu...

Descripción completa

Detalles Bibliográficos
Autores principales: Ruiz-López, Javier, Perez, Maria M., Lucena, Cristina, Pulgar, Rosa, López-Toruño, Ana, Tejada-Casado, Maria, Ghinea, Razvan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9474559/
https://www.ncbi.nlm.nih.gov/pubmed/35639206
http://dx.doi.org/10.1007/s00784-022-04556-0
_version_ 1784789746066653184
author Ruiz-López, Javier
Perez, Maria M.
Lucena, Cristina
Pulgar, Rosa
López-Toruño, Ana
Tejada-Casado, Maria
Ghinea, Razvan
author_facet Ruiz-López, Javier
Perez, Maria M.
Lucena, Cristina
Pulgar, Rosa
López-Toruño, Ana
Tejada-Casado, Maria
Ghinea, Razvan
author_sort Ruiz-López, Javier
collection PubMed
description OBJECTIVES: This study aims to evaluate in vivo the color agreement between natural teeth and dental shade guides by means of visual and instrumental coverage error ([Formula: see text] ) index. MATERIALS AND METHODS: The color of the middle third of 735 incisors was visually determined by two evaluators using the Vita Classical (VC) and Vita 3D Master (V3DM) shade guides. The color match between the natural tooth and the shade tab was rated as poor (P), good (G), or optimum (O) by each observer. CIE color coordinates of the target teeth and shade tabs of VC and V3DM were instrumentally measured using a clinical spectrophotometer. Visual ([Formula: see text] ) and instrumental ([Formula: see text] ) coverage error indexes were computed using CIELAB and CIEDE2000 metrics for both shade guides. For [Formula: see text] calculation, only the concordant inter-observer determination on tooth shade rated as O–O or O–G was used. The results were evaluated using perceptibility (PT, [Formula: see text] = 1.2, [Formula: see text] = 0.8) and acceptability (AT, [Formula: see text] = 2.7, [Formula: see text] = 1.8) color thresholds for dentistry. RESULTS: VC and V3DM exhibited [Formula: see text] (2.5, 3.2, and 3.2, 2.7 CIELAB units; 1.9, 2.3, and 2.8, 2.4 CIEDE2000 units, respectively, for O–O and O–G match) and [Formula: see text] (4.7, 4.8, and 4.1, 4.6 CIELAB units; 3.3, 3.4, and 3.4, 3.6 CIEDE2000 units, respectively, for O–O and O–G match) values greater than 50:50% AT for both color difference formulas. [Formula: see text] contributes more than 50% (53.2–82.4% range) to the [Formula: see text] value. This contribution depends on the shade guide used and the quality of the visual rating. CONCLUSIONS: The evaluated shade guides exhibited visual coverage errors above acceptability thresholds, largely due to the contribution of the instrumental coverage error to the visual coverage error. CLINICAL RELEVANCE: It necessary to further improve commercially available dental shade guides to facilitate achievement of satisfactory esthetics results in clinical practice.
format Online
Article
Text
id pubmed-9474559
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-94745592022-09-16 Visual and instrumental coverage error of two dental shade guides: an in vivo study Ruiz-López, Javier Perez, Maria M. Lucena, Cristina Pulgar, Rosa López-Toruño, Ana Tejada-Casado, Maria Ghinea, Razvan Clin Oral Investig Original Article OBJECTIVES: This study aims to evaluate in vivo the color agreement between natural teeth and dental shade guides by means of visual and instrumental coverage error ([Formula: see text] ) index. MATERIALS AND METHODS: The color of the middle third of 735 incisors was visually determined by two evaluators using the Vita Classical (VC) and Vita 3D Master (V3DM) shade guides. The color match between the natural tooth and the shade tab was rated as poor (P), good (G), or optimum (O) by each observer. CIE color coordinates of the target teeth and shade tabs of VC and V3DM were instrumentally measured using a clinical spectrophotometer. Visual ([Formula: see text] ) and instrumental ([Formula: see text] ) coverage error indexes were computed using CIELAB and CIEDE2000 metrics for both shade guides. For [Formula: see text] calculation, only the concordant inter-observer determination on tooth shade rated as O–O or O–G was used. The results were evaluated using perceptibility (PT, [Formula: see text] = 1.2, [Formula: see text] = 0.8) and acceptability (AT, [Formula: see text] = 2.7, [Formula: see text] = 1.8) color thresholds for dentistry. RESULTS: VC and V3DM exhibited [Formula: see text] (2.5, 3.2, and 3.2, 2.7 CIELAB units; 1.9, 2.3, and 2.8, 2.4 CIEDE2000 units, respectively, for O–O and O–G match) and [Formula: see text] (4.7, 4.8, and 4.1, 4.6 CIELAB units; 3.3, 3.4, and 3.4, 3.6 CIEDE2000 units, respectively, for O–O and O–G match) values greater than 50:50% AT for both color difference formulas. [Formula: see text] contributes more than 50% (53.2–82.4% range) to the [Formula: see text] value. This contribution depends on the shade guide used and the quality of the visual rating. CONCLUSIONS: The evaluated shade guides exhibited visual coverage errors above acceptability thresholds, largely due to the contribution of the instrumental coverage error to the visual coverage error. CLINICAL RELEVANCE: It necessary to further improve commercially available dental shade guides to facilitate achievement of satisfactory esthetics results in clinical practice. Springer Berlin Heidelberg 2022-05-31 2022 /pmc/articles/PMC9474559/ /pubmed/35639206 http://dx.doi.org/10.1007/s00784-022-04556-0 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Ruiz-López, Javier
Perez, Maria M.
Lucena, Cristina
Pulgar, Rosa
López-Toruño, Ana
Tejada-Casado, Maria
Ghinea, Razvan
Visual and instrumental coverage error of two dental shade guides: an in vivo study
title Visual and instrumental coverage error of two dental shade guides: an in vivo study
title_full Visual and instrumental coverage error of two dental shade guides: an in vivo study
title_fullStr Visual and instrumental coverage error of two dental shade guides: an in vivo study
title_full_unstemmed Visual and instrumental coverage error of two dental shade guides: an in vivo study
title_short Visual and instrumental coverage error of two dental shade guides: an in vivo study
title_sort visual and instrumental coverage error of two dental shade guides: an in vivo study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9474559/
https://www.ncbi.nlm.nih.gov/pubmed/35639206
http://dx.doi.org/10.1007/s00784-022-04556-0
work_keys_str_mv AT ruizlopezjavier visualandinstrumentalcoverageerroroftwodentalshadeguidesaninvivostudy
AT perezmariam visualandinstrumentalcoverageerroroftwodentalshadeguidesaninvivostudy
AT lucenacristina visualandinstrumentalcoverageerroroftwodentalshadeguidesaninvivostudy
AT pulgarrosa visualandinstrumentalcoverageerroroftwodentalshadeguidesaninvivostudy
AT lopeztorunoana visualandinstrumentalcoverageerroroftwodentalshadeguidesaninvivostudy
AT tejadacasadomaria visualandinstrumentalcoverageerroroftwodentalshadeguidesaninvivostudy
AT ghinearazvan visualandinstrumentalcoverageerroroftwodentalshadeguidesaninvivostudy