Plate osteosynthesis combined with bone cement provides the highest stability for tibial head depression fractures under high loading conditions

Older patients sustaining tibial head depression fractures often cannot follow the post-operative rehabilitation protocols with partial weight-bearing of the affected limb, leading to osteosynthesis failure, cartilage step-off and arthritis development. Therefore, the aim of this study was to analys...

Descripción completa

Detalles Bibliográficos
Autores principales: Heilig, Philipp, Faerber, Lars-Christopher, Paul, Mila M., Kupczyk, Eva, Meffert, Rainer H., Jordan, Martin C., Hoelscher-Doht, Stefanie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9474871/
https://www.ncbi.nlm.nih.gov/pubmed/36104462
http://dx.doi.org/10.1038/s41598-022-19107-6
_version_ 1784789783874109440
author Heilig, Philipp
Faerber, Lars-Christopher
Paul, Mila M.
Kupczyk, Eva
Meffert, Rainer H.
Jordan, Martin C.
Hoelscher-Doht, Stefanie
author_facet Heilig, Philipp
Faerber, Lars-Christopher
Paul, Mila M.
Kupczyk, Eva
Meffert, Rainer H.
Jordan, Martin C.
Hoelscher-Doht, Stefanie
author_sort Heilig, Philipp
collection PubMed
description Older patients sustaining tibial head depression fractures often cannot follow the post-operative rehabilitation protocols with partial weight-bearing of the affected limb, leading to osteosynthesis failure, cartilage step-off and arthritis development. Therefore, the aim of this study was to analyse the biomechanical performance of different types of osteosyntheses alone and in combination with bone cement simulating cyclically high loading conditions of tibial head depression fractures. Lateral tibial head depression fractures (AO: 41-B2.2; Schatzker type III) were created in synthetic bones and stabilized using three different osteosyntheses alone and in combination with a commonly used bone cement (chronOS™): 2 screws, 4 screws in the jail technique and a lateral angle-stable buttress plate. After fixation, the lateral tibial plateau was axially loaded in two, from each other independent testing series: In the first test protocol, 5000 cycles with 500 N and in the end load-to-failure tests were performed. In the second test protocol, the cyclic loading was increased to 1000 N. Parameters of interest were the displacement of the articular fracture fragment, the stiffness and the maximum load. The osteosyntheses revealed a higher stiffness in combination with bone cement compared to the same type of osteosynthesis alone (e.g., 500 N level: 2 screws 383 ± 43 N/mm vs. 2 screws + chronOs 520 ± 108 N/mm, increase by 36%, p < 0.01; 4 screws 368 ± 97 N/mm vs. 4 screws + chronOS 516 ± 109 N/mm, increase by 40%, p < 0.01; plate: 509 ± 73 N/mm vs. plate + chronOs 792 ± 150 N/mm, increase by 56%, p < 0.01). Bone cement reduced the displacement of the plate significantly (500 N level: plate: 8.9 ± 2.8 mm vs. plate + chronOs: 3.1 ± 1.4 mm, reduction by 65%, p < 0.01; 1000 N level: 16.9 ± 3.6 mm vs 5.6 ± 1.3 mm, reduction by 67%, p < 0.01). Thus, the highest stiffness and lowest displacement values were found when using the plate with bone cement in both loading conditions (500 N level: 2 screws + chronOs 3.7 ± 1.3 mm, 4 screws + chronOs 6.2 ± 2.4 mm; 1000 N level: 2 screws + chronOs 6.5 ± 1.2 mm, 4 screws + chronOs 5.7 ± 0.8 mm). From a biomechanical perspective, plate osteosynthesis of tibial head depression fractures should always be combined with bone cement, provides higher stability than 2-screw and 4-screw fixation and is a valid treatment option in cases where extraordinary stability is required.
format Online
Article
Text
id pubmed-9474871
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-94748712022-09-16 Plate osteosynthesis combined with bone cement provides the highest stability for tibial head depression fractures under high loading conditions Heilig, Philipp Faerber, Lars-Christopher Paul, Mila M. Kupczyk, Eva Meffert, Rainer H. Jordan, Martin C. Hoelscher-Doht, Stefanie Sci Rep Article Older patients sustaining tibial head depression fractures often cannot follow the post-operative rehabilitation protocols with partial weight-bearing of the affected limb, leading to osteosynthesis failure, cartilage step-off and arthritis development. Therefore, the aim of this study was to analyse the biomechanical performance of different types of osteosyntheses alone and in combination with bone cement simulating cyclically high loading conditions of tibial head depression fractures. Lateral tibial head depression fractures (AO: 41-B2.2; Schatzker type III) were created in synthetic bones and stabilized using three different osteosyntheses alone and in combination with a commonly used bone cement (chronOS™): 2 screws, 4 screws in the jail technique and a lateral angle-stable buttress plate. After fixation, the lateral tibial plateau was axially loaded in two, from each other independent testing series: In the first test protocol, 5000 cycles with 500 N and in the end load-to-failure tests were performed. In the second test protocol, the cyclic loading was increased to 1000 N. Parameters of interest were the displacement of the articular fracture fragment, the stiffness and the maximum load. The osteosyntheses revealed a higher stiffness in combination with bone cement compared to the same type of osteosynthesis alone (e.g., 500 N level: 2 screws 383 ± 43 N/mm vs. 2 screws + chronOs 520 ± 108 N/mm, increase by 36%, p < 0.01; 4 screws 368 ± 97 N/mm vs. 4 screws + chronOS 516 ± 109 N/mm, increase by 40%, p < 0.01; plate: 509 ± 73 N/mm vs. plate + chronOs 792 ± 150 N/mm, increase by 56%, p < 0.01). Bone cement reduced the displacement of the plate significantly (500 N level: plate: 8.9 ± 2.8 mm vs. plate + chronOs: 3.1 ± 1.4 mm, reduction by 65%, p < 0.01; 1000 N level: 16.9 ± 3.6 mm vs 5.6 ± 1.3 mm, reduction by 67%, p < 0.01). Thus, the highest stiffness and lowest displacement values were found when using the plate with bone cement in both loading conditions (500 N level: 2 screws + chronOs 3.7 ± 1.3 mm, 4 screws + chronOs 6.2 ± 2.4 mm; 1000 N level: 2 screws + chronOs 6.5 ± 1.2 mm, 4 screws + chronOs 5.7 ± 0.8 mm). From a biomechanical perspective, plate osteosynthesis of tibial head depression fractures should always be combined with bone cement, provides higher stability than 2-screw and 4-screw fixation and is a valid treatment option in cases where extraordinary stability is required. Nature Publishing Group UK 2022-09-14 /pmc/articles/PMC9474871/ /pubmed/36104462 http://dx.doi.org/10.1038/s41598-022-19107-6 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Heilig, Philipp
Faerber, Lars-Christopher
Paul, Mila M.
Kupczyk, Eva
Meffert, Rainer H.
Jordan, Martin C.
Hoelscher-Doht, Stefanie
Plate osteosynthesis combined with bone cement provides the highest stability for tibial head depression fractures under high loading conditions
title Plate osteosynthesis combined with bone cement provides the highest stability for tibial head depression fractures under high loading conditions
title_full Plate osteosynthesis combined with bone cement provides the highest stability for tibial head depression fractures under high loading conditions
title_fullStr Plate osteosynthesis combined with bone cement provides the highest stability for tibial head depression fractures under high loading conditions
title_full_unstemmed Plate osteosynthesis combined with bone cement provides the highest stability for tibial head depression fractures under high loading conditions
title_short Plate osteosynthesis combined with bone cement provides the highest stability for tibial head depression fractures under high loading conditions
title_sort plate osteosynthesis combined with bone cement provides the highest stability for tibial head depression fractures under high loading conditions
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9474871/
https://www.ncbi.nlm.nih.gov/pubmed/36104462
http://dx.doi.org/10.1038/s41598-022-19107-6
work_keys_str_mv AT heiligphilipp plateosteosynthesiscombinedwithbonecementprovidesthehigheststabilityfortibialheaddepressionfracturesunderhighloadingconditions
AT faerberlarschristopher plateosteosynthesiscombinedwithbonecementprovidesthehigheststabilityfortibialheaddepressionfracturesunderhighloadingconditions
AT paulmilam plateosteosynthesiscombinedwithbonecementprovidesthehigheststabilityfortibialheaddepressionfracturesunderhighloadingconditions
AT kupczykeva plateosteosynthesiscombinedwithbonecementprovidesthehigheststabilityfortibialheaddepressionfracturesunderhighloadingconditions
AT meffertrainerh plateosteosynthesiscombinedwithbonecementprovidesthehigheststabilityfortibialheaddepressionfracturesunderhighloadingconditions
AT jordanmartinc plateosteosynthesiscombinedwithbonecementprovidesthehigheststabilityfortibialheaddepressionfracturesunderhighloadingconditions
AT hoelscherdohtstefanie plateosteosynthesiscombinedwithbonecementprovidesthehigheststabilityfortibialheaddepressionfracturesunderhighloadingconditions