Cargando…
Platelet antibodies identification: comparison between two laboratory tests
INTRODUCTION: Platelet antibody identification is indispensable for diagnosing the human platelet antigen (HPA) or human leukocyte antigen (HLA) immunization, mostly because it can restrict the compatibility and results of transfusions. Correct detection of these antibodies is of utmost importance f...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Sociedade Brasileira de Hematologia e Hemoterapia
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9477764/ https://www.ncbi.nlm.nih.gov/pubmed/33814346 http://dx.doi.org/10.1016/j.htct.2020.12.008 |
_version_ | 1784790433815068672 |
---|---|
author | Dutra, Valeria de Freitas Costa, Thiago Henrique Santos, Leandro Dinalli Sirianni, Marilia Fernandes Mascarenhas Aravechia, Maria Giselda Kutner, José Mauro Bub, Carolina Bonet |
author_facet | Dutra, Valeria de Freitas Costa, Thiago Henrique Santos, Leandro Dinalli Sirianni, Marilia Fernandes Mascarenhas Aravechia, Maria Giselda Kutner, José Mauro Bub, Carolina Bonet |
author_sort | Dutra, Valeria de Freitas |
collection | PubMed |
description | INTRODUCTION: Platelet antibody identification is indispensable for diagnosing the human platelet antigen (HPA) or human leukocyte antigen (HLA) immunization, mostly because it can restrict the compatibility and results of transfusions. Correct detection of these antibodies is of utmost importance for the diagnosis and treatment. METHOD: We present 16 platelet alloimmunization results, comparing two tests with different technologies: the MAIPA (monoclonal antibody immobilization of platelet antigens), as a reference technique, and a bead-based assay, the Pak-Lx. RESULTS: Eleven samples (68.75%) showed agreement in both techniques. Two tests were false negatives in the Pak-Lx: a pan-reactivity in GPIIbIIIa and an anti-HPA-9b. On the other hand, the Pak-Lx was more sensitive to detect a decreasing anti-HPA-5b. The Pak-Lx found an anti-HPA-2b positive, but with a low median fluorescent intensity (MFI), suggesting a false-positive result. Moreover, in one case, the MAIPA was negative for a positive Pak-Lx HLA. CONCLUSION: Antibody platelet diagnosis can sometimes be challenging. The methods seemed similar, the Pak-Lx being faster and simpler than the MAIPA, and they can be complementary to solve clinical issues. |
format | Online Article Text |
id | pubmed-9477764 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Sociedade Brasileira de Hematologia e Hemoterapia |
record_format | MEDLINE/PubMed |
spelling | pubmed-94777642022-09-22 Platelet antibodies identification: comparison between two laboratory tests Dutra, Valeria de Freitas Costa, Thiago Henrique Santos, Leandro Dinalli Sirianni, Marilia Fernandes Mascarenhas Aravechia, Maria Giselda Kutner, José Mauro Bub, Carolina Bonet Hematol Transfus Cell Ther Original Article INTRODUCTION: Platelet antibody identification is indispensable for diagnosing the human platelet antigen (HPA) or human leukocyte antigen (HLA) immunization, mostly because it can restrict the compatibility and results of transfusions. Correct detection of these antibodies is of utmost importance for the diagnosis and treatment. METHOD: We present 16 platelet alloimmunization results, comparing two tests with different technologies: the MAIPA (monoclonal antibody immobilization of platelet antigens), as a reference technique, and a bead-based assay, the Pak-Lx. RESULTS: Eleven samples (68.75%) showed agreement in both techniques. Two tests were false negatives in the Pak-Lx: a pan-reactivity in GPIIbIIIa and an anti-HPA-9b. On the other hand, the Pak-Lx was more sensitive to detect a decreasing anti-HPA-5b. The Pak-Lx found an anti-HPA-2b positive, but with a low median fluorescent intensity (MFI), suggesting a false-positive result. Moreover, in one case, the MAIPA was negative for a positive Pak-Lx HLA. CONCLUSION: Antibody platelet diagnosis can sometimes be challenging. The methods seemed similar, the Pak-Lx being faster and simpler than the MAIPA, and they can be complementary to solve clinical issues. Sociedade Brasileira de Hematologia e Hemoterapia 2022 2021-03-06 /pmc/articles/PMC9477764/ /pubmed/33814346 http://dx.doi.org/10.1016/j.htct.2020.12.008 Text en © 2021 Associação Brasileira de Hematologia, Hemoterapia e Terapia Celular. Published by Elsevier Editora Ltda. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article Dutra, Valeria de Freitas Costa, Thiago Henrique Santos, Leandro Dinalli Sirianni, Marilia Fernandes Mascarenhas Aravechia, Maria Giselda Kutner, José Mauro Bub, Carolina Bonet Platelet antibodies identification: comparison between two laboratory tests |
title | Platelet antibodies identification: comparison between two laboratory tests |
title_full | Platelet antibodies identification: comparison between two laboratory tests |
title_fullStr | Platelet antibodies identification: comparison between two laboratory tests |
title_full_unstemmed | Platelet antibodies identification: comparison between two laboratory tests |
title_short | Platelet antibodies identification: comparison between two laboratory tests |
title_sort | platelet antibodies identification: comparison between two laboratory tests |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9477764/ https://www.ncbi.nlm.nih.gov/pubmed/33814346 http://dx.doi.org/10.1016/j.htct.2020.12.008 |
work_keys_str_mv | AT dutravaleriadefreitas plateletantibodiesidentificationcomparisonbetweentwolaboratorytests AT costathiagohenrique plateletantibodiesidentificationcomparisonbetweentwolaboratorytests AT santosleandrodinalli plateletantibodiesidentificationcomparisonbetweentwolaboratorytests AT siriannimariliafernandesmascarenhas plateletantibodiesidentificationcomparisonbetweentwolaboratorytests AT aravechiamariagiselda plateletantibodiesidentificationcomparisonbetweentwolaboratorytests AT kutnerjosemauro plateletantibodiesidentificationcomparisonbetweentwolaboratorytests AT bubcarolinabonet plateletantibodiesidentificationcomparisonbetweentwolaboratorytests |