Platelet antibodies identification: comparison between two laboratory tests

INTRODUCTION: Platelet antibody identification is indispensable for diagnosing the human platelet antigen (HPA) or human leukocyte antigen (HLA) immunization, mostly because it can restrict the compatibility and results of transfusions. Correct detection of these antibodies is of utmost importance f...

Descripción completa

Detalles Bibliográficos
Autores principales: Dutra, Valeria de Freitas, Costa, Thiago Henrique, Santos, Leandro Dinalli, Sirianni, Marilia Fernandes Mascarenhas, Aravechia, Maria Giselda, Kutner, José Mauro, Bub, Carolina Bonet
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Sociedade Brasileira de Hematologia e Hemoterapia 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9477764/
https://www.ncbi.nlm.nih.gov/pubmed/33814346
http://dx.doi.org/10.1016/j.htct.2020.12.008
_version_ 1784790433815068672
author Dutra, Valeria de Freitas
Costa, Thiago Henrique
Santos, Leandro Dinalli
Sirianni, Marilia Fernandes Mascarenhas
Aravechia, Maria Giselda
Kutner, José Mauro
Bub, Carolina Bonet
author_facet Dutra, Valeria de Freitas
Costa, Thiago Henrique
Santos, Leandro Dinalli
Sirianni, Marilia Fernandes Mascarenhas
Aravechia, Maria Giselda
Kutner, José Mauro
Bub, Carolina Bonet
author_sort Dutra, Valeria de Freitas
collection PubMed
description INTRODUCTION: Platelet antibody identification is indispensable for diagnosing the human platelet antigen (HPA) or human leukocyte antigen (HLA) immunization, mostly because it can restrict the compatibility and results of transfusions. Correct detection of these antibodies is of utmost importance for the diagnosis and treatment. METHOD: We present 16 platelet alloimmunization results, comparing two tests with different technologies: the MAIPA (monoclonal antibody immobilization of platelet antigens), as a reference technique, and a bead-based assay, the Pak-Lx. RESULTS: Eleven samples (68.75%) showed agreement in both techniques. Two tests were false negatives in the Pak-Lx: a pan-reactivity in GPIIbIIIa and an anti-HPA-9b. On the other hand, the Pak-Lx was more sensitive to detect a decreasing anti-HPA-5b. The Pak-Lx found an anti-HPA-2b positive, but with a low median fluorescent intensity (MFI), suggesting a false-positive result. Moreover, in one case, the MAIPA was negative for a positive Pak-Lx HLA. CONCLUSION: Antibody platelet diagnosis can sometimes be challenging. The methods seemed similar, the Pak-Lx being faster and simpler than the MAIPA, and they can be complementary to solve clinical issues.
format Online
Article
Text
id pubmed-9477764
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Sociedade Brasileira de Hematologia e Hemoterapia
record_format MEDLINE/PubMed
spelling pubmed-94777642022-09-22 Platelet antibodies identification: comparison between two laboratory tests Dutra, Valeria de Freitas Costa, Thiago Henrique Santos, Leandro Dinalli Sirianni, Marilia Fernandes Mascarenhas Aravechia, Maria Giselda Kutner, José Mauro Bub, Carolina Bonet Hematol Transfus Cell Ther Original Article INTRODUCTION: Platelet antibody identification is indispensable for diagnosing the human platelet antigen (HPA) or human leukocyte antigen (HLA) immunization, mostly because it can restrict the compatibility and results of transfusions. Correct detection of these antibodies is of utmost importance for the diagnosis and treatment. METHOD: We present 16 platelet alloimmunization results, comparing two tests with different technologies: the MAIPA (monoclonal antibody immobilization of platelet antigens), as a reference technique, and a bead-based assay, the Pak-Lx. RESULTS: Eleven samples (68.75%) showed agreement in both techniques. Two tests were false negatives in the Pak-Lx: a pan-reactivity in GPIIbIIIa and an anti-HPA-9b. On the other hand, the Pak-Lx was more sensitive to detect a decreasing anti-HPA-5b. The Pak-Lx found an anti-HPA-2b positive, but with a low median fluorescent intensity (MFI), suggesting a false-positive result. Moreover, in one case, the MAIPA was negative for a positive Pak-Lx HLA. CONCLUSION: Antibody platelet diagnosis can sometimes be challenging. The methods seemed similar, the Pak-Lx being faster and simpler than the MAIPA, and they can be complementary to solve clinical issues. Sociedade Brasileira de Hematologia e Hemoterapia 2022 2021-03-06 /pmc/articles/PMC9477764/ /pubmed/33814346 http://dx.doi.org/10.1016/j.htct.2020.12.008 Text en © 2021 Associação Brasileira de Hematologia, Hemoterapia e Terapia Celular. Published by Elsevier Editora Ltda. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Dutra, Valeria de Freitas
Costa, Thiago Henrique
Santos, Leandro Dinalli
Sirianni, Marilia Fernandes Mascarenhas
Aravechia, Maria Giselda
Kutner, José Mauro
Bub, Carolina Bonet
Platelet antibodies identification: comparison between two laboratory tests
title Platelet antibodies identification: comparison between two laboratory tests
title_full Platelet antibodies identification: comparison between two laboratory tests
title_fullStr Platelet antibodies identification: comparison between two laboratory tests
title_full_unstemmed Platelet antibodies identification: comparison between two laboratory tests
title_short Platelet antibodies identification: comparison between two laboratory tests
title_sort platelet antibodies identification: comparison between two laboratory tests
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9477764/
https://www.ncbi.nlm.nih.gov/pubmed/33814346
http://dx.doi.org/10.1016/j.htct.2020.12.008
work_keys_str_mv AT dutravaleriadefreitas plateletantibodiesidentificationcomparisonbetweentwolaboratorytests
AT costathiagohenrique plateletantibodiesidentificationcomparisonbetweentwolaboratorytests
AT santosleandrodinalli plateletantibodiesidentificationcomparisonbetweentwolaboratorytests
AT siriannimariliafernandesmascarenhas plateletantibodiesidentificationcomparisonbetweentwolaboratorytests
AT aravechiamariagiselda plateletantibodiesidentificationcomparisonbetweentwolaboratorytests
AT kutnerjosemauro plateletantibodiesidentificationcomparisonbetweentwolaboratorytests
AT bubcarolinabonet plateletantibodiesidentificationcomparisonbetweentwolaboratorytests