Cargando…
Integrated fan cooling of the lower back for wheelchair users
INTRODUCTION: A large proportion of a wheelchair user’s body is in contact with their wheelchair. Integrated fan cooling systems fitted to a wheelchair’s backrest aim to alleviate the build-up of heat at the skin-chair interface. The aim of this pilot study was to evaluate the effectiveness of an in...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9478711/ https://www.ncbi.nlm.nih.gov/pubmed/36118615 http://dx.doi.org/10.1177/20556683221126994 |
_version_ | 1784790633893855232 |
---|---|
author | Griggs, Katy E Vanheusden, Frederique J |
author_facet | Griggs, Katy E Vanheusden, Frederique J |
author_sort | Griggs, Katy E |
collection | PubMed |
description | INTRODUCTION: A large proportion of a wheelchair user’s body is in contact with their wheelchair. Integrated fan cooling systems fitted to a wheelchair’s backrest aim to alleviate the build-up of heat at the skin-chair interface. The aim of this pilot study was to evaluate the effectiveness of an integrated fan cooling system at cooling the user during daily pushing activity. METHODS: Eight male able-bodied participants completed two conditions, with (FAN) and without (CON) fan cooling, pushing for four 15 min blocks. The fan was turned on (highest setting) at the end of block 1 (FAN), whilst in CON the fan remained off. Skin temperature was measured over the back and chest throughout alongside heart rate and perceptual responses (rating of perceived exertion, thermal sensation, thermal comfort, wetness sensation) at the end of each 15 min block. RESULTS: Wetness sensation and lower back skin temperature were lower in FAN (both p < 0.02), with the difference in lower back skin temperature between the two conditions being 2.20°C at the end of block 4. CONCLUSION: The integrated fan cooling system provided significant cooling to the lower back without affecting any other physiological or perceptual response, besides wetness sensation. |
format | Online Article Text |
id | pubmed-9478711 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-94787112022-09-17 Integrated fan cooling of the lower back for wheelchair users Griggs, Katy E Vanheusden, Frederique J J Rehabil Assist Technol Eng Original Manuscript INTRODUCTION: A large proportion of a wheelchair user’s body is in contact with their wheelchair. Integrated fan cooling systems fitted to a wheelchair’s backrest aim to alleviate the build-up of heat at the skin-chair interface. The aim of this pilot study was to evaluate the effectiveness of an integrated fan cooling system at cooling the user during daily pushing activity. METHODS: Eight male able-bodied participants completed two conditions, with (FAN) and without (CON) fan cooling, pushing for four 15 min blocks. The fan was turned on (highest setting) at the end of block 1 (FAN), whilst in CON the fan remained off. Skin temperature was measured over the back and chest throughout alongside heart rate and perceptual responses (rating of perceived exertion, thermal sensation, thermal comfort, wetness sensation) at the end of each 15 min block. RESULTS: Wetness sensation and lower back skin temperature were lower in FAN (both p < 0.02), with the difference in lower back skin temperature between the two conditions being 2.20°C at the end of block 4. CONCLUSION: The integrated fan cooling system provided significant cooling to the lower back without affecting any other physiological or perceptual response, besides wetness sensation. SAGE Publications 2022-09-14 /pmc/articles/PMC9478711/ /pubmed/36118615 http://dx.doi.org/10.1177/20556683221126994 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Manuscript Griggs, Katy E Vanheusden, Frederique J Integrated fan cooling of the lower back for wheelchair users |
title | Integrated fan cooling of the lower back for wheelchair users |
title_full | Integrated fan cooling of the lower back for wheelchair users |
title_fullStr | Integrated fan cooling of the lower back for wheelchair users |
title_full_unstemmed | Integrated fan cooling of the lower back for wheelchair users |
title_short | Integrated fan cooling of the lower back for wheelchair users |
title_sort | integrated fan cooling of the lower back for wheelchair users |
topic | Original Manuscript |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9478711/ https://www.ncbi.nlm.nih.gov/pubmed/36118615 http://dx.doi.org/10.1177/20556683221126994 |
work_keys_str_mv | AT griggskatye integratedfancoolingofthelowerbackforwheelchairusers AT vanheusdenfrederiquej integratedfancoolingofthelowerbackforwheelchairusers |