Cargando…
Applications of Machine Learning to Improve the Clinical Viability of Compton Camera Based in vivo Range Verification in Proton Radiotherapy
We studied the application of a deep, fully connected Neural Network (NN) to process prompt gamma (PG) data measured by a Compton camera (CC) during the delivery of clinical proton radiotherapy beams. The network identifies 1) recorded “bad” PG events arising from background noise during the measure...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9481064/ https://www.ncbi.nlm.nih.gov/pubmed/36119562 http://dx.doi.org/10.3389/fphy.2022.838273 |
_version_ | 1784791178967777280 |
---|---|
author | Polf, Jerimy C. Barajas, Carlos A. Peterson, Stephen W. Mackin, Dennis S. Beddar, Sam Ren, Lei Gobbert, Matthias K. |
author_facet | Polf, Jerimy C. Barajas, Carlos A. Peterson, Stephen W. Mackin, Dennis S. Beddar, Sam Ren, Lei Gobbert, Matthias K. |
author_sort | Polf, Jerimy C. |
collection | PubMed |
description | We studied the application of a deep, fully connected Neural Network (NN) to process prompt gamma (PG) data measured by a Compton camera (CC) during the delivery of clinical proton radiotherapy beams. The network identifies 1) recorded “bad” PG events arising from background noise during the measurement, and 2) the correct ordering of PG interactions in the CC to help improve the fidelity of “good” data used for image reconstruction. PG emission from a tissue-equivalent target during irradiation with a 150 MeV proton beam delivered at clinical dose rates was measured with a prototype CC. Images were reconstructed from both the raw measured data and the measured data that was further processed with a neural network (NN) trained to identify “good” and “bad” PG events and predict the ordering of individual interactions within the good PG events. We determine if NN processing of the CC data could improve the reconstructed PG images to a level in which they could provide clinically useful information about the in vivo range and range shifts of the proton beams delivered at full clinical dose rates. Results showed that a deep, fully connected NN improved the achievable contrast to noise ratio (CNR) in our images by more than a factor of 8x. This allowed the path, range, and lateral width of the clinical proton beam within a tissue equivalent target to easily be identified from the PG images, even at the highest dose rates of a 150 MeV proton beam used for clinical treatments. On average, shifts in the beam range as small as 3 mm could be identified. However, when limited by the amount of PG data measured with our prototype CC during the delivery of a single proton pencil beam (~1 × 10(9) protons), the uncertainty in the reconstructed PG images limited the identification of range shift to ~5 mm. Substantial improvements in CC images were obtained during clinical beam delivery through NN pre-processing of the measured PG data. We believe this shows the potential of NNs to help improve and push CC-based PG imaging toward eventual clinical application for proton RT treatment delivery verification. |
format | Online Article Text |
id | pubmed-9481064 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
record_format | MEDLINE/PubMed |
spelling | pubmed-94810642022-09-16 Applications of Machine Learning to Improve the Clinical Viability of Compton Camera Based in vivo Range Verification in Proton Radiotherapy Polf, Jerimy C. Barajas, Carlos A. Peterson, Stephen W. Mackin, Dennis S. Beddar, Sam Ren, Lei Gobbert, Matthias K. Front Phys Article We studied the application of a deep, fully connected Neural Network (NN) to process prompt gamma (PG) data measured by a Compton camera (CC) during the delivery of clinical proton radiotherapy beams. The network identifies 1) recorded “bad” PG events arising from background noise during the measurement, and 2) the correct ordering of PG interactions in the CC to help improve the fidelity of “good” data used for image reconstruction. PG emission from a tissue-equivalent target during irradiation with a 150 MeV proton beam delivered at clinical dose rates was measured with a prototype CC. Images were reconstructed from both the raw measured data and the measured data that was further processed with a neural network (NN) trained to identify “good” and “bad” PG events and predict the ordering of individual interactions within the good PG events. We determine if NN processing of the CC data could improve the reconstructed PG images to a level in which they could provide clinically useful information about the in vivo range and range shifts of the proton beams delivered at full clinical dose rates. Results showed that a deep, fully connected NN improved the achievable contrast to noise ratio (CNR) in our images by more than a factor of 8x. This allowed the path, range, and lateral width of the clinical proton beam within a tissue equivalent target to easily be identified from the PG images, even at the highest dose rates of a 150 MeV proton beam used for clinical treatments. On average, shifts in the beam range as small as 3 mm could be identified. However, when limited by the amount of PG data measured with our prototype CC during the delivery of a single proton pencil beam (~1 × 10(9) protons), the uncertainty in the reconstructed PG images limited the identification of range shift to ~5 mm. Substantial improvements in CC images were obtained during clinical beam delivery through NN pre-processing of the measured PG data. We believe this shows the potential of NNs to help improve and push CC-based PG imaging toward eventual clinical application for proton RT treatment delivery verification. 2022-04 2022-04-11 /pmc/articles/PMC9481064/ /pubmed/36119562 http://dx.doi.org/10.3389/fphy.2022.838273 Text en https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY) (https://creativecommons.org/licenses/by/4.0/) . The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Article Polf, Jerimy C. Barajas, Carlos A. Peterson, Stephen W. Mackin, Dennis S. Beddar, Sam Ren, Lei Gobbert, Matthias K. Applications of Machine Learning to Improve the Clinical Viability of Compton Camera Based in vivo Range Verification in Proton Radiotherapy |
title | Applications of Machine Learning to Improve the Clinical Viability of Compton Camera Based in vivo Range Verification in Proton Radiotherapy |
title_full | Applications of Machine Learning to Improve the Clinical Viability of Compton Camera Based in vivo Range Verification in Proton Radiotherapy |
title_fullStr | Applications of Machine Learning to Improve the Clinical Viability of Compton Camera Based in vivo Range Verification in Proton Radiotherapy |
title_full_unstemmed | Applications of Machine Learning to Improve the Clinical Viability of Compton Camera Based in vivo Range Verification in Proton Radiotherapy |
title_short | Applications of Machine Learning to Improve the Clinical Viability of Compton Camera Based in vivo Range Verification in Proton Radiotherapy |
title_sort | applications of machine learning to improve the clinical viability of compton camera based in vivo range verification in proton radiotherapy |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9481064/ https://www.ncbi.nlm.nih.gov/pubmed/36119562 http://dx.doi.org/10.3389/fphy.2022.838273 |
work_keys_str_mv | AT polfjerimyc applicationsofmachinelearningtoimprovetheclinicalviabilityofcomptoncamerabasedinvivorangeverificationinprotonradiotherapy AT barajascarlosa applicationsofmachinelearningtoimprovetheclinicalviabilityofcomptoncamerabasedinvivorangeverificationinprotonradiotherapy AT petersonstephenw applicationsofmachinelearningtoimprovetheclinicalviabilityofcomptoncamerabasedinvivorangeverificationinprotonradiotherapy AT mackindenniss applicationsofmachinelearningtoimprovetheclinicalviabilityofcomptoncamerabasedinvivorangeverificationinprotonradiotherapy AT beddarsam applicationsofmachinelearningtoimprovetheclinicalviabilityofcomptoncamerabasedinvivorangeverificationinprotonradiotherapy AT renlei applicationsofmachinelearningtoimprovetheclinicalviabilityofcomptoncamerabasedinvivorangeverificationinprotonradiotherapy AT gobbertmatthiask applicationsofmachinelearningtoimprovetheclinicalviabilityofcomptoncamerabasedinvivorangeverificationinprotonradiotherapy |