Cargando…

A novel virtual reality application for autonomous assessment of cervical range of motion: development and reliability study

BACKGROUND: Neck pain, one of the most common musculoskeletal diseases, affects 222 million people worldwide. The cervical range of motion (CROM) is a tool used to assess the neck’s state across three movement axes: flexo-extension, rotation, and lateral flexion. People with neck pain often have a r...

Descripción completa

Detalles Bibliográficos
Autores principales: Santos-Paz, Jose Angel, Sánchez-Picot, Álvaro, Rojo, Ana, Martín-Pintado-Zugasti, Aitor, Otero, Abraham, Garcia-Carmona, Rodrigo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: PeerJ Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9482359/
https://www.ncbi.nlm.nih.gov/pubmed/36124134
http://dx.doi.org/10.7717/peerj.14031
_version_ 1784791436659523584
author Santos-Paz, Jose Angel
Sánchez-Picot, Álvaro
Rojo, Ana
Martín-Pintado-Zugasti, Aitor
Otero, Abraham
Garcia-Carmona, Rodrigo
author_facet Santos-Paz, Jose Angel
Sánchez-Picot, Álvaro
Rojo, Ana
Martín-Pintado-Zugasti, Aitor
Otero, Abraham
Garcia-Carmona, Rodrigo
author_sort Santos-Paz, Jose Angel
collection PubMed
description BACKGROUND: Neck pain, one of the most common musculoskeletal diseases, affects 222 million people worldwide. The cervical range of motion (CROM) is a tool used to assess the neck’s state across three movement axes: flexo-extension, rotation, and lateral flexion. People with neck pain often have a reduced CROM, and they feel pain at the end-range and/or accompany neck movements with compensatory trunk movements. Virtual reality (VR) setups can track the movement of the head and other body parts in order to create the sensation of immersion in the virtual environment. Using this tracking position information, a CROM assessment can be performed using a VR setup that may be carried out autonomously from the user’s home. The objectives of this study were to develop a VR experience that could be used to perform a CROM assessment, and to evaluate the intra-rater and inter-rater reliability of the CROM measures guided by this VR experience. To the best of our knowledge, a study of this type has not been carried out before. MATERIALS & METHODS: A total of 30 asymptomatic adults were assessed using a VR device (HTC Vive Pro Eye™). Two raters provided support with the VR setup, and the participants were guided by the VR experience as they performed the movements. Each rater tested each subject twice, in random order. In addition to a head-mounted display (HMD), a tracker located on the subject’s back was used to measure trunk compensatory movements. The CROM was estimated using only the HMD position and this measurement was corrected using the tracker data. The mean and standard deviation were calculated to characterize the CROM. To evaluate the reliability, the interclass correlation coefficients (ICC) were calculated for intra-rater and inter-rater analysis. The standard error of measurement and minimum detectable change were also calculated. The usability of the VR system was measured using the Spanish version of the System Usability Scale. RESULTS: The mean CROM values in each axis of movement were compatible with those described in the literature. ICC values ranged between 0.86 and 0.96 in the intra-rater analysis and between 0.83 and 0.97 in the inter-rater analysis; these values were between good and excellent. When applying the correction of the trunk movements, both the intra-rater and inter-rater ICC values slightly worsened except in the case of the lateral flexion movement, where they slightly improved. The usability score of the CROM assessment/VR system was 86 points, which is an excellent usability score. CONCLUSION: The reliability of the measurements and the usability of the system indicate that a VR setup can be used to assess CROM. The reliability of the VR setup can be affected by slippage of the HMD or tracker. Both slippage errors are additive, i.e., only when the sum of these two errors is less than the compensatory movement do the measurements improve when considering the tracker data.
format Online
Article
Text
id pubmed-9482359
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher PeerJ Inc.
record_format MEDLINE/PubMed
spelling pubmed-94823592022-09-18 A novel virtual reality application for autonomous assessment of cervical range of motion: development and reliability study Santos-Paz, Jose Angel Sánchez-Picot, Álvaro Rojo, Ana Martín-Pintado-Zugasti, Aitor Otero, Abraham Garcia-Carmona, Rodrigo PeerJ Anatomy and Physiology BACKGROUND: Neck pain, one of the most common musculoskeletal diseases, affects 222 million people worldwide. The cervical range of motion (CROM) is a tool used to assess the neck’s state across three movement axes: flexo-extension, rotation, and lateral flexion. People with neck pain often have a reduced CROM, and they feel pain at the end-range and/or accompany neck movements with compensatory trunk movements. Virtual reality (VR) setups can track the movement of the head and other body parts in order to create the sensation of immersion in the virtual environment. Using this tracking position information, a CROM assessment can be performed using a VR setup that may be carried out autonomously from the user’s home. The objectives of this study were to develop a VR experience that could be used to perform a CROM assessment, and to evaluate the intra-rater and inter-rater reliability of the CROM measures guided by this VR experience. To the best of our knowledge, a study of this type has not been carried out before. MATERIALS & METHODS: A total of 30 asymptomatic adults were assessed using a VR device (HTC Vive Pro Eye™). Two raters provided support with the VR setup, and the participants were guided by the VR experience as they performed the movements. Each rater tested each subject twice, in random order. In addition to a head-mounted display (HMD), a tracker located on the subject’s back was used to measure trunk compensatory movements. The CROM was estimated using only the HMD position and this measurement was corrected using the tracker data. The mean and standard deviation were calculated to characterize the CROM. To evaluate the reliability, the interclass correlation coefficients (ICC) were calculated for intra-rater and inter-rater analysis. The standard error of measurement and minimum detectable change were also calculated. The usability of the VR system was measured using the Spanish version of the System Usability Scale. RESULTS: The mean CROM values in each axis of movement were compatible with those described in the literature. ICC values ranged between 0.86 and 0.96 in the intra-rater analysis and between 0.83 and 0.97 in the inter-rater analysis; these values were between good and excellent. When applying the correction of the trunk movements, both the intra-rater and inter-rater ICC values slightly worsened except in the case of the lateral flexion movement, where they slightly improved. The usability score of the CROM assessment/VR system was 86 points, which is an excellent usability score. CONCLUSION: The reliability of the measurements and the usability of the system indicate that a VR setup can be used to assess CROM. The reliability of the VR setup can be affected by slippage of the HMD or tracker. Both slippage errors are additive, i.e., only when the sum of these two errors is less than the compensatory movement do the measurements improve when considering the tracker data. PeerJ Inc. 2022-09-14 /pmc/articles/PMC9482359/ /pubmed/36124134 http://dx.doi.org/10.7717/peerj.14031 Text en ©2022 Santos-Paz et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, reproduction and adaptation in any medium and for any purpose provided that it is properly attributed. For attribution, the original author(s), title, publication source (PeerJ) and either DOI or URL of the article must be cited.
spellingShingle Anatomy and Physiology
Santos-Paz, Jose Angel
Sánchez-Picot, Álvaro
Rojo, Ana
Martín-Pintado-Zugasti, Aitor
Otero, Abraham
Garcia-Carmona, Rodrigo
A novel virtual reality application for autonomous assessment of cervical range of motion: development and reliability study
title A novel virtual reality application for autonomous assessment of cervical range of motion: development and reliability study
title_full A novel virtual reality application for autonomous assessment of cervical range of motion: development and reliability study
title_fullStr A novel virtual reality application for autonomous assessment of cervical range of motion: development and reliability study
title_full_unstemmed A novel virtual reality application for autonomous assessment of cervical range of motion: development and reliability study
title_short A novel virtual reality application for autonomous assessment of cervical range of motion: development and reliability study
title_sort novel virtual reality application for autonomous assessment of cervical range of motion: development and reliability study
topic Anatomy and Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9482359/
https://www.ncbi.nlm.nih.gov/pubmed/36124134
http://dx.doi.org/10.7717/peerj.14031
work_keys_str_mv AT santospazjoseangel anovelvirtualrealityapplicationforautonomousassessmentofcervicalrangeofmotiondevelopmentandreliabilitystudy
AT sanchezpicotalvaro anovelvirtualrealityapplicationforautonomousassessmentofcervicalrangeofmotiondevelopmentandreliabilitystudy
AT rojoana anovelvirtualrealityapplicationforautonomousassessmentofcervicalrangeofmotiondevelopmentandreliabilitystudy
AT martinpintadozugastiaitor anovelvirtualrealityapplicationforautonomousassessmentofcervicalrangeofmotiondevelopmentandreliabilitystudy
AT oteroabraham anovelvirtualrealityapplicationforautonomousassessmentofcervicalrangeofmotiondevelopmentandreliabilitystudy
AT garciacarmonarodrigo anovelvirtualrealityapplicationforautonomousassessmentofcervicalrangeofmotiondevelopmentandreliabilitystudy
AT santospazjoseangel novelvirtualrealityapplicationforautonomousassessmentofcervicalrangeofmotiondevelopmentandreliabilitystudy
AT sanchezpicotalvaro novelvirtualrealityapplicationforautonomousassessmentofcervicalrangeofmotiondevelopmentandreliabilitystudy
AT rojoana novelvirtualrealityapplicationforautonomousassessmentofcervicalrangeofmotiondevelopmentandreliabilitystudy
AT martinpintadozugastiaitor novelvirtualrealityapplicationforautonomousassessmentofcervicalrangeofmotiondevelopmentandreliabilitystudy
AT oteroabraham novelvirtualrealityapplicationforautonomousassessmentofcervicalrangeofmotiondevelopmentandreliabilitystudy
AT garciacarmonarodrigo novelvirtualrealityapplicationforautonomousassessmentofcervicalrangeofmotiondevelopmentandreliabilitystudy