Cargando…

Compass Fundus-Guided Perimetry in Geographic Atrophy

PURPOSE: To evaluate compass (CMP), a recently introduced device that combines scanning ophthalmoscopy, automated perimetry, and eye tracking, for fundus-guided perimetry (microperimetry) with the purpose of correlating perimetric retinal sensitivity (PRS) and retinal geographic atrophy (GA) feature...

Descripción completa

Detalles Bibliográficos
Autores principales: Farci, Roberta, Carta, Arturo, Fogagnolo, Paolo, Rossetti, Luca Mario, Fossarello, Maurizio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9482498/
https://www.ncbi.nlm.nih.gov/pubmed/36124138
http://dx.doi.org/10.1155/2022/1315588
_version_ 1784791468598099968
author Farci, Roberta
Carta, Arturo
Fogagnolo, Paolo
Rossetti, Luca Mario
Fossarello, Maurizio
author_facet Farci, Roberta
Carta, Arturo
Fogagnolo, Paolo
Rossetti, Luca Mario
Fossarello, Maurizio
author_sort Farci, Roberta
collection PubMed
description PURPOSE: To evaluate compass (CMP), a recently introduced device that combines scanning ophthalmoscopy, automated perimetry, and eye tracking, for fundus-guided perimetry (microperimetry) with the purpose of correlating perimetric retinal sensitivity (PRS) and retinal geographic atrophy (GA) features. MATERIALS AND METHODS: A retrospective, cross-sectional study was performed in 56 eyes of 43 patients affected by GA. All patients underwent compass 10-2 perimetry, consisting of a full-threshold visual field on fundus photography and an infrared (IR) image of the central 30° of the retina. Data were exported to an Excel sheet. Binarization with black/white (B/W) variables was applied on the compass photo fundus and matched with visual field scores. Patients underwent autofluorescence (AF) and IR images (Heidelberg, Germany): CMP and Heidelberg IR images were homologated by using GIMP software (https://www.gimp.org), and then atrophic areas were manually measured with the ImageJ program. CMP perimetric grid was overlapped with AF and IR pictures by using GIMP, obtaining composite TIFF images, which were then analyzed with the ImageJ greyscale score (GSS) tool. A hyperautofluorescent halo was identified on the GA edges of some patients. Pearson's correlation between GA size on IR compass and IR Heidelberg and between GSS and PRS values has been calculated; the independent t-test was realized to calculate the correlation between GSS and B/W variables identified on the CMP photo fundus. The Spearman correlation between total deviation and pattern deviation was calculated. RESULTS: The AUC-ROC score between CMP scores and B/W variables was 93,4%. The Spearman correlation between total deviation and pattern deviation was highly significant (p = 0,00). The correlation between AF GSS values and PRS was significant (p value = 0,00), the correlation between GSS of hyperautofluorescent points and PRS was significant (p value = 0,00), and the correlation between IR GSS and PRS was significant (p value = 0,00). The correlation between AF GSS and B/W variables was significant (p value = 0,002), the correlation between hyperautofluorescent points and B/W was not significant (p value = 0,40), and the correlation between IR GSS and B/W was significant (p = 0,00). CONCLUSIONS: Based on our preliminary results, compass seems to be a reliable, quick, and safe device for the anatomical and functional study of GA. The direct visualization of the visual field on the fundus photography as a background allows a precise assessment and clinical monitoring of this disease.
format Online
Article
Text
id pubmed-9482498
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-94824982022-09-18 Compass Fundus-Guided Perimetry in Geographic Atrophy Farci, Roberta Carta, Arturo Fogagnolo, Paolo Rossetti, Luca Mario Fossarello, Maurizio J Ophthalmol Research Article PURPOSE: To evaluate compass (CMP), a recently introduced device that combines scanning ophthalmoscopy, automated perimetry, and eye tracking, for fundus-guided perimetry (microperimetry) with the purpose of correlating perimetric retinal sensitivity (PRS) and retinal geographic atrophy (GA) features. MATERIALS AND METHODS: A retrospective, cross-sectional study was performed in 56 eyes of 43 patients affected by GA. All patients underwent compass 10-2 perimetry, consisting of a full-threshold visual field on fundus photography and an infrared (IR) image of the central 30° of the retina. Data were exported to an Excel sheet. Binarization with black/white (B/W) variables was applied on the compass photo fundus and matched with visual field scores. Patients underwent autofluorescence (AF) and IR images (Heidelberg, Germany): CMP and Heidelberg IR images were homologated by using GIMP software (https://www.gimp.org), and then atrophic areas were manually measured with the ImageJ program. CMP perimetric grid was overlapped with AF and IR pictures by using GIMP, obtaining composite TIFF images, which were then analyzed with the ImageJ greyscale score (GSS) tool. A hyperautofluorescent halo was identified on the GA edges of some patients. Pearson's correlation between GA size on IR compass and IR Heidelberg and between GSS and PRS values has been calculated; the independent t-test was realized to calculate the correlation between GSS and B/W variables identified on the CMP photo fundus. The Spearman correlation between total deviation and pattern deviation was calculated. RESULTS: The AUC-ROC score between CMP scores and B/W variables was 93,4%. The Spearman correlation between total deviation and pattern deviation was highly significant (p = 0,00). The correlation between AF GSS values and PRS was significant (p value = 0,00), the correlation between GSS of hyperautofluorescent points and PRS was significant (p value = 0,00), and the correlation between IR GSS and PRS was significant (p value = 0,00). The correlation between AF GSS and B/W variables was significant (p value = 0,002), the correlation between hyperautofluorescent points and B/W was not significant (p value = 0,40), and the correlation between IR GSS and B/W was significant (p = 0,00). CONCLUSIONS: Based on our preliminary results, compass seems to be a reliable, quick, and safe device for the anatomical and functional study of GA. The direct visualization of the visual field on the fundus photography as a background allows a precise assessment and clinical monitoring of this disease. Hindawi 2022-09-10 /pmc/articles/PMC9482498/ /pubmed/36124138 http://dx.doi.org/10.1155/2022/1315588 Text en Copyright © 2022 Roberta Farci et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Farci, Roberta
Carta, Arturo
Fogagnolo, Paolo
Rossetti, Luca Mario
Fossarello, Maurizio
Compass Fundus-Guided Perimetry in Geographic Atrophy
title Compass Fundus-Guided Perimetry in Geographic Atrophy
title_full Compass Fundus-Guided Perimetry in Geographic Atrophy
title_fullStr Compass Fundus-Guided Perimetry in Geographic Atrophy
title_full_unstemmed Compass Fundus-Guided Perimetry in Geographic Atrophy
title_short Compass Fundus-Guided Perimetry in Geographic Atrophy
title_sort compass fundus-guided perimetry in geographic atrophy
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9482498/
https://www.ncbi.nlm.nih.gov/pubmed/36124138
http://dx.doi.org/10.1155/2022/1315588
work_keys_str_mv AT farciroberta compassfundusguidedperimetryingeographicatrophy
AT cartaarturo compassfundusguidedperimetryingeographicatrophy
AT fogagnolopaolo compassfundusguidedperimetryingeographicatrophy
AT rossettilucamario compassfundusguidedperimetryingeographicatrophy
AT fossarellomaurizio compassfundusguidedperimetryingeographicatrophy