Cargando…
Sensitive and selective determination of vitamin B2 in non-alcoholic beverage and milk samples at poly (glutamic acid)/zinc oxide nanoparticles modified carbon paste electrode
BACKGROUND: The deficiency of vitamin B2 can lead to many health problems. Therefore, it is necessary to develop a sensitive, selective and fast method for the determination of vitamin B2 in food samples. In this work, a sensitive, selective and low-cost electrochemical sensor was developed using po...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9482753/ https://www.ncbi.nlm.nih.gov/pubmed/36117181 http://dx.doi.org/10.1186/s13065-022-00863-5 |
_version_ | 1784791524112859136 |
---|---|
author | Tesfaye, Gizaw Negash, Negussie Tessema, Merid |
author_facet | Tesfaye, Gizaw Negash, Negussie Tessema, Merid |
author_sort | Tesfaye, Gizaw |
collection | PubMed |
description | BACKGROUND: The deficiency of vitamin B2 can lead to many health problems. Therefore, it is necessary to develop a sensitive, selective and fast method for the determination of vitamin B2 in food samples. In this work, a sensitive, selective and low-cost electrochemical sensor was developed using poly (glutamic acid) and Zinc oxide nanoparticles (ZnO NPs) for vitamin B2 in non-alcoholic beverage and milk samples. METHODS: The modification of the electrode surface was carried out by electropolymerization of glutamic acid on ZnO NPs–carbon paste electrode (ZnO NPS–CPE). The prepared electrodes were characterized by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), scanning electron microscopy (SEM) and X-Ray diffraction (XRD). CV and square wave voltammetry (SWV) were used to investigate the electrochemical behavior of vitamin B2 at the modified electrode. The effect of various parameters such as amount of ZnO NPs, polymerization cycle, concentration of the monomer, pH, scan rate and accumulation time were optimized to obtain maximum sensitivity at the modified electrode. RESULTS: The developed sensor showed high electrocatalytic activity towards vitamin B2. Under the optimized conditions, the developed sensor showed a linear response in the range 0.005–10 µM with a low detection limit of (LOD) 0.0007 ± 0.00001 µM and high sensitivity of 21.53 µA/µM. CONCLUSIONS: A reproducible, repeatable, stable and selective sensor was successfully applied for the quantification of vitamin B2 in beverage and milk samples with acceptable recoveries in the range of 88–101%. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13065-022-00863-5. |
format | Online Article Text |
id | pubmed-9482753 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-94827532022-09-19 Sensitive and selective determination of vitamin B2 in non-alcoholic beverage and milk samples at poly (glutamic acid)/zinc oxide nanoparticles modified carbon paste electrode Tesfaye, Gizaw Negash, Negussie Tessema, Merid BMC Chem Research BACKGROUND: The deficiency of vitamin B2 can lead to many health problems. Therefore, it is necessary to develop a sensitive, selective and fast method for the determination of vitamin B2 in food samples. In this work, a sensitive, selective and low-cost electrochemical sensor was developed using poly (glutamic acid) and Zinc oxide nanoparticles (ZnO NPs) for vitamin B2 in non-alcoholic beverage and milk samples. METHODS: The modification of the electrode surface was carried out by electropolymerization of glutamic acid on ZnO NPs–carbon paste electrode (ZnO NPS–CPE). The prepared electrodes were characterized by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), scanning electron microscopy (SEM) and X-Ray diffraction (XRD). CV and square wave voltammetry (SWV) were used to investigate the electrochemical behavior of vitamin B2 at the modified electrode. The effect of various parameters such as amount of ZnO NPs, polymerization cycle, concentration of the monomer, pH, scan rate and accumulation time were optimized to obtain maximum sensitivity at the modified electrode. RESULTS: The developed sensor showed high electrocatalytic activity towards vitamin B2. Under the optimized conditions, the developed sensor showed a linear response in the range 0.005–10 µM with a low detection limit of (LOD) 0.0007 ± 0.00001 µM and high sensitivity of 21.53 µA/µM. CONCLUSIONS: A reproducible, repeatable, stable and selective sensor was successfully applied for the quantification of vitamin B2 in beverage and milk samples with acceptable recoveries in the range of 88–101%. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13065-022-00863-5. Springer International Publishing 2022-09-18 /pmc/articles/PMC9482753/ /pubmed/36117181 http://dx.doi.org/10.1186/s13065-022-00863-5 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Tesfaye, Gizaw Negash, Negussie Tessema, Merid Sensitive and selective determination of vitamin B2 in non-alcoholic beverage and milk samples at poly (glutamic acid)/zinc oxide nanoparticles modified carbon paste electrode |
title | Sensitive and selective determination of vitamin B2 in non-alcoholic beverage and milk samples at poly (glutamic acid)/zinc oxide nanoparticles modified carbon paste electrode |
title_full | Sensitive and selective determination of vitamin B2 in non-alcoholic beverage and milk samples at poly (glutamic acid)/zinc oxide nanoparticles modified carbon paste electrode |
title_fullStr | Sensitive and selective determination of vitamin B2 in non-alcoholic beverage and milk samples at poly (glutamic acid)/zinc oxide nanoparticles modified carbon paste electrode |
title_full_unstemmed | Sensitive and selective determination of vitamin B2 in non-alcoholic beverage and milk samples at poly (glutamic acid)/zinc oxide nanoparticles modified carbon paste electrode |
title_short | Sensitive and selective determination of vitamin B2 in non-alcoholic beverage and milk samples at poly (glutamic acid)/zinc oxide nanoparticles modified carbon paste electrode |
title_sort | sensitive and selective determination of vitamin b2 in non-alcoholic beverage and milk samples at poly (glutamic acid)/zinc oxide nanoparticles modified carbon paste electrode |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9482753/ https://www.ncbi.nlm.nih.gov/pubmed/36117181 http://dx.doi.org/10.1186/s13065-022-00863-5 |
work_keys_str_mv | AT tesfayegizaw sensitiveandselectivedeterminationofvitaminb2innonalcoholicbeverageandmilksamplesatpolyglutamicacidzincoxidenanoparticlesmodifiedcarbonpasteelectrode AT negashnegussie sensitiveandselectivedeterminationofvitaminb2innonalcoholicbeverageandmilksamplesatpolyglutamicacidzincoxidenanoparticlesmodifiedcarbonpasteelectrode AT tessemamerid sensitiveandselectivedeterminationofvitaminb2innonalcoholicbeverageandmilksamplesatpolyglutamicacidzincoxidenanoparticlesmodifiedcarbonpasteelectrode |