Mechanical consequences at the tendon-bone interface of different medial row knotless configurations and lateral row tension in a simulated rotator cuff repair
PURPOSE: Little is known about the direct influence of different technical options at the rotator cuff tendon-bone interface (TBI) and, more specifically, at the medial bearing row (MBR), regarding local contact force, area and pressure. We evaluated the mechanical repercussions of different medial...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9482894/ https://www.ncbi.nlm.nih.gov/pubmed/36117186 http://dx.doi.org/10.1186/s40634-022-00536-1 |
_version_ | 1784791553414266880 |
---|---|
author | Maia Dias, Carlos Gonçalves, Sérgio B. Completo, António da Silva, Manuel Ribeiro de Campos Azevedo, Clara Mineiro, Jorge Ferreira, Frederico Folgado, João |
author_facet | Maia Dias, Carlos Gonçalves, Sérgio B. Completo, António da Silva, Manuel Ribeiro de Campos Azevedo, Clara Mineiro, Jorge Ferreira, Frederico Folgado, João |
author_sort | Maia Dias, Carlos |
collection | PubMed |
description | PURPOSE: Little is known about the direct influence of different technical options at the rotator cuff tendon-bone interface (TBI) and, more specifically, at the medial bearing row (MBR), regarding local contact force, area and pressure. We evaluated the mechanical repercussions of different medial row anchor configurations for that setting using different values of tension in the lateral row anchors. METHODS: Knotless transosseous equivalent (TOE) rotator cuff repairs with locked versus nonlocked medial anchors and single versus double-hole suture passage were tested in a synthetic rotator cuff mechanical model, using 2 different values of lateral row tension. Contact force, area, pressure, peak force and MBR force were compared at the simulated TBI using a pressure mapping sensor. RESULTS: When compared to locked anchors, medial row sliding configurations generate lower values for all the above-mentioned parameters. The use of double-hole suture passage in the medial cuff generated slightly higher values contact area regardless of lateral row tension. At higher lateral row tension values, lower values of the remaining parameters, including MBR force, were found when compared to single-hole suture passage. Lateral row anchor tension increase induced an increase of all parameters regardless of the medial row configuration and TBI contact force and MBR force were the most susceptible parameters, regardless of the medial row pattern. CONCLUSION: Medial row mechanism, suture configuration and lateral row tension interfere with the mechanical force, area and pressure at by TBI. Lateral row tension increase is a major influencer in those parameters. These results can help surgeons choose the right technique considering its mechanical effect at the TBI. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s40634-022-00536-1. |
format | Online Article Text |
id | pubmed-9482894 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-94828942022-10-21 Mechanical consequences at the tendon-bone interface of different medial row knotless configurations and lateral row tension in a simulated rotator cuff repair Maia Dias, Carlos Gonçalves, Sérgio B. Completo, António da Silva, Manuel Ribeiro de Campos Azevedo, Clara Mineiro, Jorge Ferreira, Frederico Folgado, João J Exp Orthop Original Paper PURPOSE: Little is known about the direct influence of different technical options at the rotator cuff tendon-bone interface (TBI) and, more specifically, at the medial bearing row (MBR), regarding local contact force, area and pressure. We evaluated the mechanical repercussions of different medial row anchor configurations for that setting using different values of tension in the lateral row anchors. METHODS: Knotless transosseous equivalent (TOE) rotator cuff repairs with locked versus nonlocked medial anchors and single versus double-hole suture passage were tested in a synthetic rotator cuff mechanical model, using 2 different values of lateral row tension. Contact force, area, pressure, peak force and MBR force were compared at the simulated TBI using a pressure mapping sensor. RESULTS: When compared to locked anchors, medial row sliding configurations generate lower values for all the above-mentioned parameters. The use of double-hole suture passage in the medial cuff generated slightly higher values contact area regardless of lateral row tension. At higher lateral row tension values, lower values of the remaining parameters, including MBR force, were found when compared to single-hole suture passage. Lateral row anchor tension increase induced an increase of all parameters regardless of the medial row configuration and TBI contact force and MBR force were the most susceptible parameters, regardless of the medial row pattern. CONCLUSION: Medial row mechanism, suture configuration and lateral row tension interfere with the mechanical force, area and pressure at by TBI. Lateral row tension increase is a major influencer in those parameters. These results can help surgeons choose the right technique considering its mechanical effect at the TBI. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s40634-022-00536-1. Springer Berlin Heidelberg 2022-09-19 /pmc/articles/PMC9482894/ /pubmed/36117186 http://dx.doi.org/10.1186/s40634-022-00536-1 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Paper Maia Dias, Carlos Gonçalves, Sérgio B. Completo, António da Silva, Manuel Ribeiro de Campos Azevedo, Clara Mineiro, Jorge Ferreira, Frederico Folgado, João Mechanical consequences at the tendon-bone interface of different medial row knotless configurations and lateral row tension in a simulated rotator cuff repair |
title | Mechanical consequences at the tendon-bone interface of different medial row knotless configurations and lateral row tension in a simulated rotator cuff repair |
title_full | Mechanical consequences at the tendon-bone interface of different medial row knotless configurations and lateral row tension in a simulated rotator cuff repair |
title_fullStr | Mechanical consequences at the tendon-bone interface of different medial row knotless configurations and lateral row tension in a simulated rotator cuff repair |
title_full_unstemmed | Mechanical consequences at the tendon-bone interface of different medial row knotless configurations and lateral row tension in a simulated rotator cuff repair |
title_short | Mechanical consequences at the tendon-bone interface of different medial row knotless configurations and lateral row tension in a simulated rotator cuff repair |
title_sort | mechanical consequences at the tendon-bone interface of different medial row knotless configurations and lateral row tension in a simulated rotator cuff repair |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9482894/ https://www.ncbi.nlm.nih.gov/pubmed/36117186 http://dx.doi.org/10.1186/s40634-022-00536-1 |
work_keys_str_mv | AT maiadiascarlos mechanicalconsequencesatthetendonboneinterfaceofdifferentmedialrowknotlessconfigurationsandlateralrowtensioninasimulatedrotatorcuffrepair AT goncalvessergiob mechanicalconsequencesatthetendonboneinterfaceofdifferentmedialrowknotlessconfigurationsandlateralrowtensioninasimulatedrotatorcuffrepair AT completoantonio mechanicalconsequencesatthetendonboneinterfaceofdifferentmedialrowknotlessconfigurationsandlateralrowtensioninasimulatedrotatorcuffrepair AT dasilvamanuelribeiro mechanicalconsequencesatthetendonboneinterfaceofdifferentmedialrowknotlessconfigurationsandlateralrowtensioninasimulatedrotatorcuffrepair AT decamposazevedoclara mechanicalconsequencesatthetendonboneinterfaceofdifferentmedialrowknotlessconfigurationsandlateralrowtensioninasimulatedrotatorcuffrepair AT mineirojorge mechanicalconsequencesatthetendonboneinterfaceofdifferentmedialrowknotlessconfigurationsandlateralrowtensioninasimulatedrotatorcuffrepair AT ferreirafrederico mechanicalconsequencesatthetendonboneinterfaceofdifferentmedialrowknotlessconfigurationsandlateralrowtensioninasimulatedrotatorcuffrepair AT folgadojoao mechanicalconsequencesatthetendonboneinterfaceofdifferentmedialrowknotlessconfigurationsandlateralrowtensioninasimulatedrotatorcuffrepair |