Cargando…

A Prospective Observational Study on the Tolerability of Transnasal Bronchoscopy With a Surgical Mask for Aerosol Control

Background As far as we know, there are no reports comparing the safety and cough frequency of transnasal bronchoscopy (TNB) with transoral bronchoscopy (TOB). Methods The subjects were 50 patients who underwent either TNB or TOB and completed the pain score questionnaire between May and November 20...

Descripción completa

Detalles Bibliográficos
Autores principales: Usui, Yusuke, Sasada, Shinji, Kirita, Keisuke, Nagayama, Sayaka, Murata, Saori, Tsuchiya, Yumi, Ishioka, Kota, Takahashi, Saeko, Nakamura, Morio, Kishi, Kazuma
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9484221/
https://www.ncbi.nlm.nih.gov/pubmed/36158445
http://dx.doi.org/10.7759/cureus.28197
_version_ 1784791834765033472
author Usui, Yusuke
Sasada, Shinji
Kirita, Keisuke
Nagayama, Sayaka
Murata, Saori
Tsuchiya, Yumi
Ishioka, Kota
Takahashi, Saeko
Nakamura, Morio
Kishi, Kazuma
author_facet Usui, Yusuke
Sasada, Shinji
Kirita, Keisuke
Nagayama, Sayaka
Murata, Saori
Tsuchiya, Yumi
Ishioka, Kota
Takahashi, Saeko
Nakamura, Morio
Kishi, Kazuma
author_sort Usui, Yusuke
collection PubMed
description Background As far as we know, there are no reports comparing the safety and cough frequency of transnasal bronchoscopy (TNB) with transoral bronchoscopy (TOB). Methods The subjects were 50 patients who underwent either TNB or TOB and completed the pain score questionnaire between May and November 2020. Complications, pain scores, and cough frequency (times per minute) were compared between the patients with TNB and TOB. A surgical mask was worn over the mouthpiece during the examination. Results Thirty-two and 18 patients underwent TNB and TOB, respectively. Between the two groups, there were no significant differences in examination time and frequency of serious complications. In pain scores, there were no significant differences in terms of anesthesia suffering, several pains during the examination, and availability of re-examination. The TNB group did not feel the prolonged examination time compared to the TOB group (p=0.04). Cough frequency was lower in the TNB group than in the TOB group (0.36 vs 0.73, p=0.027). Moreover, cough frequency in the 25 TNB patients who underwent thin bronchoscopy was significantly lower (0.19 vs 0.73, p<0.01). Conclusions TNB with a surgical mask was well tolerated and safe. Cough frequency in the transnasal thin bronchoscopy was extremely low, suggesting aerosol reduction can be expected.
format Online
Article
Text
id pubmed-9484221
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-94842212022-09-22 A Prospective Observational Study on the Tolerability of Transnasal Bronchoscopy With a Surgical Mask for Aerosol Control Usui, Yusuke Sasada, Shinji Kirita, Keisuke Nagayama, Sayaka Murata, Saori Tsuchiya, Yumi Ishioka, Kota Takahashi, Saeko Nakamura, Morio Kishi, Kazuma Cureus Pulmonology Background As far as we know, there are no reports comparing the safety and cough frequency of transnasal bronchoscopy (TNB) with transoral bronchoscopy (TOB). Methods The subjects were 50 patients who underwent either TNB or TOB and completed the pain score questionnaire between May and November 2020. Complications, pain scores, and cough frequency (times per minute) were compared between the patients with TNB and TOB. A surgical mask was worn over the mouthpiece during the examination. Results Thirty-two and 18 patients underwent TNB and TOB, respectively. Between the two groups, there were no significant differences in examination time and frequency of serious complications. In pain scores, there were no significant differences in terms of anesthesia suffering, several pains during the examination, and availability of re-examination. The TNB group did not feel the prolonged examination time compared to the TOB group (p=0.04). Cough frequency was lower in the TNB group than in the TOB group (0.36 vs 0.73, p=0.027). Moreover, cough frequency in the 25 TNB patients who underwent thin bronchoscopy was significantly lower (0.19 vs 0.73, p<0.01). Conclusions TNB with a surgical mask was well tolerated and safe. Cough frequency in the transnasal thin bronchoscopy was extremely low, suggesting aerosol reduction can be expected. Cureus 2022-08-20 /pmc/articles/PMC9484221/ /pubmed/36158445 http://dx.doi.org/10.7759/cureus.28197 Text en Copyright © 2022, Usui et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Pulmonology
Usui, Yusuke
Sasada, Shinji
Kirita, Keisuke
Nagayama, Sayaka
Murata, Saori
Tsuchiya, Yumi
Ishioka, Kota
Takahashi, Saeko
Nakamura, Morio
Kishi, Kazuma
A Prospective Observational Study on the Tolerability of Transnasal Bronchoscopy With a Surgical Mask for Aerosol Control
title A Prospective Observational Study on the Tolerability of Transnasal Bronchoscopy With a Surgical Mask for Aerosol Control
title_full A Prospective Observational Study on the Tolerability of Transnasal Bronchoscopy With a Surgical Mask for Aerosol Control
title_fullStr A Prospective Observational Study on the Tolerability of Transnasal Bronchoscopy With a Surgical Mask for Aerosol Control
title_full_unstemmed A Prospective Observational Study on the Tolerability of Transnasal Bronchoscopy With a Surgical Mask for Aerosol Control
title_short A Prospective Observational Study on the Tolerability of Transnasal Bronchoscopy With a Surgical Mask for Aerosol Control
title_sort prospective observational study on the tolerability of transnasal bronchoscopy with a surgical mask for aerosol control
topic Pulmonology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9484221/
https://www.ncbi.nlm.nih.gov/pubmed/36158445
http://dx.doi.org/10.7759/cureus.28197
work_keys_str_mv AT usuiyusuke aprospectiveobservationalstudyonthetolerabilityoftransnasalbronchoscopywithasurgicalmaskforaerosolcontrol
AT sasadashinji aprospectiveobservationalstudyonthetolerabilityoftransnasalbronchoscopywithasurgicalmaskforaerosolcontrol
AT kiritakeisuke aprospectiveobservationalstudyonthetolerabilityoftransnasalbronchoscopywithasurgicalmaskforaerosolcontrol
AT nagayamasayaka aprospectiveobservationalstudyonthetolerabilityoftransnasalbronchoscopywithasurgicalmaskforaerosolcontrol
AT muratasaori aprospectiveobservationalstudyonthetolerabilityoftransnasalbronchoscopywithasurgicalmaskforaerosolcontrol
AT tsuchiyayumi aprospectiveobservationalstudyonthetolerabilityoftransnasalbronchoscopywithasurgicalmaskforaerosolcontrol
AT ishiokakota aprospectiveobservationalstudyonthetolerabilityoftransnasalbronchoscopywithasurgicalmaskforaerosolcontrol
AT takahashisaeko aprospectiveobservationalstudyonthetolerabilityoftransnasalbronchoscopywithasurgicalmaskforaerosolcontrol
AT nakamuramorio aprospectiveobservationalstudyonthetolerabilityoftransnasalbronchoscopywithasurgicalmaskforaerosolcontrol
AT kishikazuma aprospectiveobservationalstudyonthetolerabilityoftransnasalbronchoscopywithasurgicalmaskforaerosolcontrol
AT usuiyusuke prospectiveobservationalstudyonthetolerabilityoftransnasalbronchoscopywithasurgicalmaskforaerosolcontrol
AT sasadashinji prospectiveobservationalstudyonthetolerabilityoftransnasalbronchoscopywithasurgicalmaskforaerosolcontrol
AT kiritakeisuke prospectiveobservationalstudyonthetolerabilityoftransnasalbronchoscopywithasurgicalmaskforaerosolcontrol
AT nagayamasayaka prospectiveobservationalstudyonthetolerabilityoftransnasalbronchoscopywithasurgicalmaskforaerosolcontrol
AT muratasaori prospectiveobservationalstudyonthetolerabilityoftransnasalbronchoscopywithasurgicalmaskforaerosolcontrol
AT tsuchiyayumi prospectiveobservationalstudyonthetolerabilityoftransnasalbronchoscopywithasurgicalmaskforaerosolcontrol
AT ishiokakota prospectiveobservationalstudyonthetolerabilityoftransnasalbronchoscopywithasurgicalmaskforaerosolcontrol
AT takahashisaeko prospectiveobservationalstudyonthetolerabilityoftransnasalbronchoscopywithasurgicalmaskforaerosolcontrol
AT nakamuramorio prospectiveobservationalstudyonthetolerabilityoftransnasalbronchoscopywithasurgicalmaskforaerosolcontrol
AT kishikazuma prospectiveobservationalstudyonthetolerabilityoftransnasalbronchoscopywithasurgicalmaskforaerosolcontrol