Cargando…
Helical plating for a re-nonunion and a peri-implant fracture after humeral intramedullary nailing: A report of two cases
INTRODUCTION AND IMPORTANCE: A re-nonunion after failed intramedullary nailing for a nonunion of the humeral shaft and a peri-implant distal humeral fracture with an ununited humeral shaft are rare cases. Therefore, no consensus has been established regarding the treatment strategies. CASE PRESENTAT...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9486657/ https://www.ncbi.nlm.nih.gov/pubmed/36147059 http://dx.doi.org/10.1016/j.amsu.2022.104442 |
_version_ | 1784792328640135168 |
---|---|
author | Nohmi, Shuya Suzuki, Masahiro Sakamoto, Yukiko |
author_facet | Nohmi, Shuya Suzuki, Masahiro Sakamoto, Yukiko |
author_sort | Nohmi, Shuya |
collection | PubMed |
description | INTRODUCTION AND IMPORTANCE: A re-nonunion after failed intramedullary nailing for a nonunion of the humeral shaft and a peri-implant distal humeral fracture with an ununited humeral shaft are rare cases. Therefore, no consensus has been established regarding the treatment strategies. CASE PRESENTATION: Case 1: An 84-year-old woman presented with humeral shaft re-nonunion after intramedullary nailing. The images revealed callus formation and loosening of the implant, suggesting a lack of mechanical stability. Nail removal and helical plating were performed. One year postoperatively, bony union was achieved. Case 2: A 59-year-old woman presented with a peri-implant distal humeral fracture with an ununited humeral shaft after nailing. Nail removal and helical plating were performed using a minimally invasive plate osteosynthesis (MIPO) technique. The distal humeral fracture was fixed with plates. One year postoperatively, bony union was achieved. CLINICAL DISCUSSION: Imaging findings in Case 1 indicated that nonunion was caused by a lack of mechanical stability. In Case 2, stabilization of the ununited humeral shaft was also needed. Helical plating provides a mechanically strong fixation and prevents damage to the radial nerve and soft tissues. CONCLUSION: Evaluating the causative factors of nonunions is important. Helical plating provides mechanical stability and is associated with bony union without autologous bone grafting for a re-nonunion of humeral shaft lacking mechanical instability. For a peri-implant distal humeral fracture with an ununited humeral shaft, helical plating with the MIPO technique provides diaphyseal fracture union and enables the minimal length of distal humeral plate fixation. |
format | Online Article Text |
id | pubmed-9486657 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-94866572022-09-21 Helical plating for a re-nonunion and a peri-implant fracture after humeral intramedullary nailing: A report of two cases Nohmi, Shuya Suzuki, Masahiro Sakamoto, Yukiko Ann Med Surg (Lond) Case Report INTRODUCTION AND IMPORTANCE: A re-nonunion after failed intramedullary nailing for a nonunion of the humeral shaft and a peri-implant distal humeral fracture with an ununited humeral shaft are rare cases. Therefore, no consensus has been established regarding the treatment strategies. CASE PRESENTATION: Case 1: An 84-year-old woman presented with humeral shaft re-nonunion after intramedullary nailing. The images revealed callus formation and loosening of the implant, suggesting a lack of mechanical stability. Nail removal and helical plating were performed. One year postoperatively, bony union was achieved. Case 2: A 59-year-old woman presented with a peri-implant distal humeral fracture with an ununited humeral shaft after nailing. Nail removal and helical plating were performed using a minimally invasive plate osteosynthesis (MIPO) technique. The distal humeral fracture was fixed with plates. One year postoperatively, bony union was achieved. CLINICAL DISCUSSION: Imaging findings in Case 1 indicated that nonunion was caused by a lack of mechanical stability. In Case 2, stabilization of the ununited humeral shaft was also needed. Helical plating provides a mechanically strong fixation and prevents damage to the radial nerve and soft tissues. CONCLUSION: Evaluating the causative factors of nonunions is important. Helical plating provides mechanical stability and is associated with bony union without autologous bone grafting for a re-nonunion of humeral shaft lacking mechanical instability. For a peri-implant distal humeral fracture with an ununited humeral shaft, helical plating with the MIPO technique provides diaphyseal fracture union and enables the minimal length of distal humeral plate fixation. Elsevier 2022-08-18 /pmc/articles/PMC9486657/ /pubmed/36147059 http://dx.doi.org/10.1016/j.amsu.2022.104442 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case Report Nohmi, Shuya Suzuki, Masahiro Sakamoto, Yukiko Helical plating for a re-nonunion and a peri-implant fracture after humeral intramedullary nailing: A report of two cases |
title | Helical plating for a re-nonunion and a peri-implant fracture after humeral intramedullary nailing: A report of two cases |
title_full | Helical plating for a re-nonunion and a peri-implant fracture after humeral intramedullary nailing: A report of two cases |
title_fullStr | Helical plating for a re-nonunion and a peri-implant fracture after humeral intramedullary nailing: A report of two cases |
title_full_unstemmed | Helical plating for a re-nonunion and a peri-implant fracture after humeral intramedullary nailing: A report of two cases |
title_short | Helical plating for a re-nonunion and a peri-implant fracture after humeral intramedullary nailing: A report of two cases |
title_sort | helical plating for a re-nonunion and a peri-implant fracture after humeral intramedullary nailing: a report of two cases |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9486657/ https://www.ncbi.nlm.nih.gov/pubmed/36147059 http://dx.doi.org/10.1016/j.amsu.2022.104442 |
work_keys_str_mv | AT nohmishuya helicalplatingforarenonunionandaperiimplantfractureafterhumeralintramedullarynailingareportoftwocases AT suzukimasahiro helicalplatingforarenonunionandaperiimplantfractureafterhumeralintramedullarynailingareportoftwocases AT sakamotoyukiko helicalplatingforarenonunionandaperiimplantfractureafterhumeralintramedullarynailingareportoftwocases |