Cargando…

Helical plating for a re-nonunion and a peri-implant fracture after humeral intramedullary nailing: A report of two cases

INTRODUCTION AND IMPORTANCE: A re-nonunion after failed intramedullary nailing for a nonunion of the humeral shaft and a peri-implant distal humeral fracture with an ununited humeral shaft are rare cases. Therefore, no consensus has been established regarding the treatment strategies. CASE PRESENTAT...

Descripción completa

Detalles Bibliográficos
Autores principales: Nohmi, Shuya, Suzuki, Masahiro, Sakamoto, Yukiko
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9486657/
https://www.ncbi.nlm.nih.gov/pubmed/36147059
http://dx.doi.org/10.1016/j.amsu.2022.104442

Ejemplares similares