Cargando…

Haemolysis resolution after transcatheter valve in valve within a prior mitral annuloplasty ring: a case report

BACKGROUND: Transcatheter mitral valve in ring procedure has emerged as a minimally invasive alternative to re-do surgery among patients with failed mitral annuloplasty rings. Uncommonly, haemolysis presents as a complication after the percutaneous valvular procedures and often require aggressive me...

Descripción completa

Detalles Bibliográficos
Autores principales: Bhardwaj, Bhaskar, Golwala, Harsh, Song, Howard K, Lantz, Gurion, Chadderdon, Scott, Zahr, Firas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9486913/
https://www.ncbi.nlm.nih.gov/pubmed/36131810
http://dx.doi.org/10.1093/ehjcr/ytac326
_version_ 1784792382827397120
author Bhardwaj, Bhaskar
Golwala, Harsh
Song, Howard K
Lantz, Gurion
Chadderdon, Scott
Zahr, Firas
author_facet Bhardwaj, Bhaskar
Golwala, Harsh
Song, Howard K
Lantz, Gurion
Chadderdon, Scott
Zahr, Firas
author_sort Bhardwaj, Bhaskar
collection PubMed
description BACKGROUND: Transcatheter mitral valve in ring procedure has emerged as a minimally invasive alternative to re-do surgery among patients with failed mitral annuloplasty rings. Uncommonly, haemolysis presents as a complication after the percutaneous valvular procedures and often require aggressive measures to correct paravalvular leaks and mechanical collision. CASE SUMMARY: We report a case of an 82-year-old female who underwent a transcatheter valve in ring procedure (Edwards Sapien S3, Edwards Lifesciences) for symptomatic severe mitral regurgitation from a bioprosthetic annuloplasty ring failure complicated by acute haemolytic anaemia a week after the procedure manifesting as dark coloured urine, profound icterus, and acute renal injury. She was treated with a post-dilation balloon valvuloplasty leading to reduction in haemolysis, but the patient was readmitted with acute haemolysis episode again. At this time, a decision was made to perform a repeat valve in valve TMVR with a 29 mm S3 Edwards Sapien valve which led to a resolution of haemolysis. DISCUSSION: In this case, the leaflets of previously placed S3 valve sealed the blood flow through the valve frame thus diverting the blood flow away from the area of collision leading to resolution of haemolysis.
format Online
Article
Text
id pubmed-9486913
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-94869132022-09-20 Haemolysis resolution after transcatheter valve in valve within a prior mitral annuloplasty ring: a case report Bhardwaj, Bhaskar Golwala, Harsh Song, Howard K Lantz, Gurion Chadderdon, Scott Zahr, Firas Eur Heart J Case Rep Case Report BACKGROUND: Transcatheter mitral valve in ring procedure has emerged as a minimally invasive alternative to re-do surgery among patients with failed mitral annuloplasty rings. Uncommonly, haemolysis presents as a complication after the percutaneous valvular procedures and often require aggressive measures to correct paravalvular leaks and mechanical collision. CASE SUMMARY: We report a case of an 82-year-old female who underwent a transcatheter valve in ring procedure (Edwards Sapien S3, Edwards Lifesciences) for symptomatic severe mitral regurgitation from a bioprosthetic annuloplasty ring failure complicated by acute haemolytic anaemia a week after the procedure manifesting as dark coloured urine, profound icterus, and acute renal injury. She was treated with a post-dilation balloon valvuloplasty leading to reduction in haemolysis, but the patient was readmitted with acute haemolysis episode again. At this time, a decision was made to perform a repeat valve in valve TMVR with a 29 mm S3 Edwards Sapien valve which led to a resolution of haemolysis. DISCUSSION: In this case, the leaflets of previously placed S3 valve sealed the blood flow through the valve frame thus diverting the blood flow away from the area of collision leading to resolution of haemolysis. Oxford University Press 2022-08-03 /pmc/articles/PMC9486913/ /pubmed/36131810 http://dx.doi.org/10.1093/ehjcr/ytac326 Text en © The Author(s) 2022. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Case Report
Bhardwaj, Bhaskar
Golwala, Harsh
Song, Howard K
Lantz, Gurion
Chadderdon, Scott
Zahr, Firas
Haemolysis resolution after transcatheter valve in valve within a prior mitral annuloplasty ring: a case report
title Haemolysis resolution after transcatheter valve in valve within a prior mitral annuloplasty ring: a case report
title_full Haemolysis resolution after transcatheter valve in valve within a prior mitral annuloplasty ring: a case report
title_fullStr Haemolysis resolution after transcatheter valve in valve within a prior mitral annuloplasty ring: a case report
title_full_unstemmed Haemolysis resolution after transcatheter valve in valve within a prior mitral annuloplasty ring: a case report
title_short Haemolysis resolution after transcatheter valve in valve within a prior mitral annuloplasty ring: a case report
title_sort haemolysis resolution after transcatheter valve in valve within a prior mitral annuloplasty ring: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9486913/
https://www.ncbi.nlm.nih.gov/pubmed/36131810
http://dx.doi.org/10.1093/ehjcr/ytac326
work_keys_str_mv AT bhardwajbhaskar haemolysisresolutionaftertranscathetervalveinvalvewithinapriormitralannuloplastyringacasereport
AT golwalaharsh haemolysisresolutionaftertranscathetervalveinvalvewithinapriormitralannuloplastyringacasereport
AT songhowardk haemolysisresolutionaftertranscathetervalveinvalvewithinapriormitralannuloplastyringacasereport
AT lantzgurion haemolysisresolutionaftertranscathetervalveinvalvewithinapriormitralannuloplastyringacasereport
AT chadderdonscott haemolysisresolutionaftertranscathetervalveinvalvewithinapriormitralannuloplastyringacasereport
AT zahrfiras haemolysisresolutionaftertranscathetervalveinvalvewithinapriormitralannuloplastyringacasereport