Cargando…

Distribution Pattern of Total Corneal Thickness in Keratoconus versus Normal Eyes Using an Optical Coherence Tomography

PURPOSE: To evaluate the total corneal thickness distribution pattern using a high-resolution spectral-domain optical coherence tomography (HR SD-OCT) for distinguishing normal eyes from keratoconus (KCN). METHODS: One hundred and forty-four patients were enrolled in three groups (55 normal, 45 mild...

Descripción completa

Detalles Bibliográficos
Autores principales: Hashemi, Hassan, Heidari, Zahra, Mohammadpour, Mehrdad, Momeni-Moghaddam, Hamed, Khabazkhoob, Mehdi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9487006/
https://www.ncbi.nlm.nih.gov/pubmed/36147258
http://dx.doi.org/10.4103/joco.joco_198_21
_version_ 1784792401568595968
author Hashemi, Hassan
Heidari, Zahra
Mohammadpour, Mehrdad
Momeni-Moghaddam, Hamed
Khabazkhoob, Mehdi
author_facet Hashemi, Hassan
Heidari, Zahra
Mohammadpour, Mehrdad
Momeni-Moghaddam, Hamed
Khabazkhoob, Mehdi
author_sort Hashemi, Hassan
collection PubMed
description PURPOSE: To evaluate the total corneal thickness distribution pattern using a high-resolution spectral-domain optical coherence tomography (HR SD-OCT) for distinguishing normal eyes from keratoconus (KCN). METHODS: One hundred and forty-four patients were enrolled in three groups (55 normal, 45 mild KCN, and 44 moderate-to-severe KCN eyes) in this prospective diagnostic test study. Total corneal thickness was measured in 8 semi-meridians using HR SD-OCT (Heidelberg Engineering, Heidelberg, Germany) in 5 and 7 mm zones. The central corneal thickness (CCT), corneal focal thinning (minimum thickness [Min], min minus median and maximum [Min-Med, Min-Max]), and asymmetry indices (inferior minus superior [I-S] and supranasal minus infratemporal [SN-IT]) were calculated. One-way analysis of variance and the area under the receiver operating characteristic curve (AUC) were used for the analysis. RESULTS: Thinner CCT, lower Min thickness, more negative Min-Max, Min-Med, and greater I-S and SN-IT were found in KCN eyes compared to the control group (P < 0.001). The inferior and IT semi-meridians were the thinnest locations in KCN cases in the 5 mm central zone (P < 0.001). CCT followed by Min-Med had the highest discriminative ability for differentiating mild KCN (AUC, sensitivity and specificity: 0.822, 87.0%, 60.37% and 0.805, 82.93%, 66.0%, respectively) and moderate-to-severe KCN (0.902, 87.82%, 73.08% and 0.892, 85.37%, and 78.85%, respectively) from normal corneas. CONCLUSION: The inferior and IT sectors of the cornea with the largest thickness changes in the 5 mm zone are the most common thinning sites in keratoconic corneas, and CCT and Min-Med are the most sensitive indices for the diagnosis of KCN.
format Online
Article
Text
id pubmed-9487006
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-94870062022-09-21 Distribution Pattern of Total Corneal Thickness in Keratoconus versus Normal Eyes Using an Optical Coherence Tomography Hashemi, Hassan Heidari, Zahra Mohammadpour, Mehrdad Momeni-Moghaddam, Hamed Khabazkhoob, Mehdi J Curr Ophthalmol Original Article PURPOSE: To evaluate the total corneal thickness distribution pattern using a high-resolution spectral-domain optical coherence tomography (HR SD-OCT) for distinguishing normal eyes from keratoconus (KCN). METHODS: One hundred and forty-four patients were enrolled in three groups (55 normal, 45 mild KCN, and 44 moderate-to-severe KCN eyes) in this prospective diagnostic test study. Total corneal thickness was measured in 8 semi-meridians using HR SD-OCT (Heidelberg Engineering, Heidelberg, Germany) in 5 and 7 mm zones. The central corneal thickness (CCT), corneal focal thinning (minimum thickness [Min], min minus median and maximum [Min-Med, Min-Max]), and asymmetry indices (inferior minus superior [I-S] and supranasal minus infratemporal [SN-IT]) were calculated. One-way analysis of variance and the area under the receiver operating characteristic curve (AUC) were used for the analysis. RESULTS: Thinner CCT, lower Min thickness, more negative Min-Max, Min-Med, and greater I-S and SN-IT were found in KCN eyes compared to the control group (P < 0.001). The inferior and IT semi-meridians were the thinnest locations in KCN cases in the 5 mm central zone (P < 0.001). CCT followed by Min-Med had the highest discriminative ability for differentiating mild KCN (AUC, sensitivity and specificity: 0.822, 87.0%, 60.37% and 0.805, 82.93%, 66.0%, respectively) and moderate-to-severe KCN (0.902, 87.82%, 73.08% and 0.892, 85.37%, and 78.85%, respectively) from normal corneas. CONCLUSION: The inferior and IT sectors of the cornea with the largest thickness changes in the 5 mm zone are the most common thinning sites in keratoconic corneas, and CCT and Min-Med are the most sensitive indices for the diagnosis of KCN. Wolters Kluwer - Medknow 2022-07-26 /pmc/articles/PMC9487006/ /pubmed/36147258 http://dx.doi.org/10.4103/joco.joco_198_21 Text en Copyright: © 2022 Journal of Current Ophthalmology https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Hashemi, Hassan
Heidari, Zahra
Mohammadpour, Mehrdad
Momeni-Moghaddam, Hamed
Khabazkhoob, Mehdi
Distribution Pattern of Total Corneal Thickness in Keratoconus versus Normal Eyes Using an Optical Coherence Tomography
title Distribution Pattern of Total Corneal Thickness in Keratoconus versus Normal Eyes Using an Optical Coherence Tomography
title_full Distribution Pattern of Total Corneal Thickness in Keratoconus versus Normal Eyes Using an Optical Coherence Tomography
title_fullStr Distribution Pattern of Total Corneal Thickness in Keratoconus versus Normal Eyes Using an Optical Coherence Tomography
title_full_unstemmed Distribution Pattern of Total Corneal Thickness in Keratoconus versus Normal Eyes Using an Optical Coherence Tomography
title_short Distribution Pattern of Total Corneal Thickness in Keratoconus versus Normal Eyes Using an Optical Coherence Tomography
title_sort distribution pattern of total corneal thickness in keratoconus versus normal eyes using an optical coherence tomography
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9487006/
https://www.ncbi.nlm.nih.gov/pubmed/36147258
http://dx.doi.org/10.4103/joco.joco_198_21
work_keys_str_mv AT hashemihassan distributionpatternoftotalcornealthicknessinkeratoconusversusnormaleyesusinganopticalcoherencetomography
AT heidarizahra distributionpatternoftotalcornealthicknessinkeratoconusversusnormaleyesusinganopticalcoherencetomography
AT mohammadpourmehrdad distributionpatternoftotalcornealthicknessinkeratoconusversusnormaleyesusinganopticalcoherencetomography
AT momenimoghaddamhamed distributionpatternoftotalcornealthicknessinkeratoconusversusnormaleyesusinganopticalcoherencetomography
AT khabazkhoobmehdi distributionpatternoftotalcornealthicknessinkeratoconusversusnormaleyesusinganopticalcoherencetomography