Cargando…

Ready-to-implement low-carbon retrofit of coal-fired power plants in China: Optimal scenarios selection based on sludge and photovoltaic utilization

Currently the flexible demand for high proportion penetration of renewable energy depends on coal-fired units (CFUs), and the large-scale phase-out of CFUs in a short time is not realistic in China. Due to urban expansion, approximately 458 Chinese coal-fired power plants (CFPPs) are now located in...

Descripción completa

Detalles Bibliográficos
Autores principales: Xia, Yunchao, Deng, Jian, Hu, Bo, Yang, Qing, Li, Jianlan, Gu, Hongqun, Zhou, Guiping
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9488090/
https://www.ncbi.nlm.nih.gov/pubmed/36157856
http://dx.doi.org/10.1016/j.ese.2022.100147
_version_ 1784792584225292288
author Xia, Yunchao
Deng, Jian
Hu, Bo
Yang, Qing
Li, Jianlan
Gu, Hongqun
Zhou, Guiping
author_facet Xia, Yunchao
Deng, Jian
Hu, Bo
Yang, Qing
Li, Jianlan
Gu, Hongqun
Zhou, Guiping
author_sort Xia, Yunchao
collection PubMed
description Currently the flexible demand for high proportion penetration of renewable energy depends on coal-fired units (CFUs), and the large-scale phase-out of CFUs in a short time is not realistic in China. Due to urban expansion, approximately 458 Chinese coal-fired power plants (CFPPs) are now located in cities. Limited by space, urban CFUs face difficulty in becoming equipped with carbon capture and storage systems. This presents a sizeable challenge for the low-carbon transition of urban CFPPs and carbon neutral processes. Here, we present a ready-to-implement method to reduce the carbon emission of CFPPs in limited space: roof photovoltaic-assisted power generation combined with sludge co-combustion for coal-fired power generation systems (PVSCs). We also consider nonurban CFPPs with the method of roof photovoltaic-assisted power generation (PVs) only. Based on remaining life cycle analysis, we find that the PVSCs could save 28.47 Mt of coal, reduce CO(2) emissions by 69.76 Mt, treat 125.70 Mt of sludge, and also generate 12.08 billion RMB worth of electricity revenue per year. In addition, our scenario analysis shows that PVSCs are more profitable when choosing an urban CFU with a remaining life of more than 12 years and while the sludge treatment subsidy is set at 100 RMB t(−1). Under strict and lenient CFU decommissioning policies, CFUs with a remaining life of between 19 and 30 years and between 13 and 24 years should be selected for PVs, respectively. Thus, we conclude that PVSCs can not only generate economic benefits but also facilitate carbon reduction and solid waste treatment.
format Online
Article
Text
id pubmed-9488090
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-94880902022-09-23 Ready-to-implement low-carbon retrofit of coal-fired power plants in China: Optimal scenarios selection based on sludge and photovoltaic utilization Xia, Yunchao Deng, Jian Hu, Bo Yang, Qing Li, Jianlan Gu, Hongqun Zhou, Guiping Environ Sci Ecotechnol Original Research Currently the flexible demand for high proportion penetration of renewable energy depends on coal-fired units (CFUs), and the large-scale phase-out of CFUs in a short time is not realistic in China. Due to urban expansion, approximately 458 Chinese coal-fired power plants (CFPPs) are now located in cities. Limited by space, urban CFUs face difficulty in becoming equipped with carbon capture and storage systems. This presents a sizeable challenge for the low-carbon transition of urban CFPPs and carbon neutral processes. Here, we present a ready-to-implement method to reduce the carbon emission of CFPPs in limited space: roof photovoltaic-assisted power generation combined with sludge co-combustion for coal-fired power generation systems (PVSCs). We also consider nonurban CFPPs with the method of roof photovoltaic-assisted power generation (PVs) only. Based on remaining life cycle analysis, we find that the PVSCs could save 28.47 Mt of coal, reduce CO(2) emissions by 69.76 Mt, treat 125.70 Mt of sludge, and also generate 12.08 billion RMB worth of electricity revenue per year. In addition, our scenario analysis shows that PVSCs are more profitable when choosing an urban CFU with a remaining life of more than 12 years and while the sludge treatment subsidy is set at 100 RMB t(−1). Under strict and lenient CFU decommissioning policies, CFUs with a remaining life of between 19 and 30 years and between 13 and 24 years should be selected for PVs, respectively. Thus, we conclude that PVSCs can not only generate economic benefits but also facilitate carbon reduction and solid waste treatment. Elsevier 2022-02-01 /pmc/articles/PMC9488090/ /pubmed/36157856 http://dx.doi.org/10.1016/j.ese.2022.100147 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research
Xia, Yunchao
Deng, Jian
Hu, Bo
Yang, Qing
Li, Jianlan
Gu, Hongqun
Zhou, Guiping
Ready-to-implement low-carbon retrofit of coal-fired power plants in China: Optimal scenarios selection based on sludge and photovoltaic utilization
title Ready-to-implement low-carbon retrofit of coal-fired power plants in China: Optimal scenarios selection based on sludge and photovoltaic utilization
title_full Ready-to-implement low-carbon retrofit of coal-fired power plants in China: Optimal scenarios selection based on sludge and photovoltaic utilization
title_fullStr Ready-to-implement low-carbon retrofit of coal-fired power plants in China: Optimal scenarios selection based on sludge and photovoltaic utilization
title_full_unstemmed Ready-to-implement low-carbon retrofit of coal-fired power plants in China: Optimal scenarios selection based on sludge and photovoltaic utilization
title_short Ready-to-implement low-carbon retrofit of coal-fired power plants in China: Optimal scenarios selection based on sludge and photovoltaic utilization
title_sort ready-to-implement low-carbon retrofit of coal-fired power plants in china: optimal scenarios selection based on sludge and photovoltaic utilization
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9488090/
https://www.ncbi.nlm.nih.gov/pubmed/36157856
http://dx.doi.org/10.1016/j.ese.2022.100147
work_keys_str_mv AT xiayunchao readytoimplementlowcarbonretrofitofcoalfiredpowerplantsinchinaoptimalscenariosselectionbasedonsludgeandphotovoltaicutilization
AT dengjian readytoimplementlowcarbonretrofitofcoalfiredpowerplantsinchinaoptimalscenariosselectionbasedonsludgeandphotovoltaicutilization
AT hubo readytoimplementlowcarbonretrofitofcoalfiredpowerplantsinchinaoptimalscenariosselectionbasedonsludgeandphotovoltaicutilization
AT yangqing readytoimplementlowcarbonretrofitofcoalfiredpowerplantsinchinaoptimalscenariosselectionbasedonsludgeandphotovoltaicutilization
AT lijianlan readytoimplementlowcarbonretrofitofcoalfiredpowerplantsinchinaoptimalscenariosselectionbasedonsludgeandphotovoltaicutilization
AT guhongqun readytoimplementlowcarbonretrofitofcoalfiredpowerplantsinchinaoptimalscenariosselectionbasedonsludgeandphotovoltaicutilization
AT zhouguiping readytoimplementlowcarbonretrofitofcoalfiredpowerplantsinchinaoptimalscenariosselectionbasedonsludgeandphotovoltaicutilization