Stability of internal fixation systems based on different subtypes of Schatzker II fracture of the tibial plateau: A finite element analysis

Background: Schaztker II fracture is the most common type of the tibial plateau fractures (TPF). There has been a large number of cadaveric biomechanical studies and finite element simulation studies to explore the most stable fixation methods for this type of fracture, which were based on a single...

Descripción completa

Detalles Bibliográficos
Autores principales: Zeng, Chuyang, Ren, Xiaomeng, Xu, Cheng, Hu, Mengmeng, Li, Jiantao, Zhang, Wei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9490054/
https://www.ncbi.nlm.nih.gov/pubmed/36159683
http://dx.doi.org/10.3389/fbioe.2022.973389
_version_ 1784793007365554176
author Zeng, Chuyang
Ren, Xiaomeng
Xu, Cheng
Hu, Mengmeng
Li, Jiantao
Zhang, Wei
author_facet Zeng, Chuyang
Ren, Xiaomeng
Xu, Cheng
Hu, Mengmeng
Li, Jiantao
Zhang, Wei
author_sort Zeng, Chuyang
collection PubMed
description Background: Schaztker II fracture is the most common type of the tibial plateau fractures (TPF). There has been a large number of cadaveric biomechanical studies and finite element simulation studies to explore the most stable fixation methods for this type of fracture, which were based on a single fracture morphology. But differences among fracture morphologies could directly affect the stability of internal fixation systems. In this sense, we verified the stability of existing internal fixation modalities by simulating Schatzker II fractures with different fracture morphologies. Objectives: To compare the stability of different filler types combined with locked compression plate/screw in different subtypes of Schatzker II TPF. Methods: Four subtypes of Schatzker II were created based on 3D map of TPF. Each of the subtypes was fixed with LCP/screw or LCP/screw combined with different fill types. Stress distribution, displacement distribution, and the load sharing capacity of the filler were assessed by applying the maximum load during gait. In addition, repeated fracture risks of depressed fragment were evaluated regarding to the ultimate strain of bone. Results: The stress concentration of the implant in each scenario was located on the screw at the contact site between the plate and the screw, and the filler of the defect site significantly reduced the stress concentration of the implant (Subtype A: Blank group 402.0 MPa vs. Experimental group 315.2 ± 5.5 MPa; Subtype C: Blank group 385.0 MPa vs. Experimental group 322.7 ± 12.1 MPa). Displacement field analysis showed that filler significantly reduced the reduction loss of the depressed fragment (Subtype A: Blank group 0.1949 mm vs. Experimental group 0.174 ± 0.001 mm; Subtype C: 0.264 mm vs. 0.253 ± 0.002 mm). Maximum strain was in subtype C with the value of 2.3% ± 0.1% indicating the greatest possibility of failure risk. And with the increase of its modulus, the bearing capacity of filler increased. Conclusion: The existence of filler at the defect site can effectively reduce the stress concentration of the implant and the reduction loss of the collapsed block, thus providing good stability for Schatzker II fracture. In subtype A fracture, the modulus of filler presented the slightest influence on the stability, followed by subtype C, while the stability of subtype B was most influenced by the modulus of filler. Therefore, it is necessary to evaluate the preoperative patient imaging data adequately to select the appropriate stiffness of the filler.
format Online
Article
Text
id pubmed-9490054
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-94900542022-09-22 Stability of internal fixation systems based on different subtypes of Schatzker II fracture of the tibial plateau: A finite element analysis Zeng, Chuyang Ren, Xiaomeng Xu, Cheng Hu, Mengmeng Li, Jiantao Zhang, Wei Front Bioeng Biotechnol Bioengineering and Biotechnology Background: Schaztker II fracture is the most common type of the tibial plateau fractures (TPF). There has been a large number of cadaveric biomechanical studies and finite element simulation studies to explore the most stable fixation methods for this type of fracture, which were based on a single fracture morphology. But differences among fracture morphologies could directly affect the stability of internal fixation systems. In this sense, we verified the stability of existing internal fixation modalities by simulating Schatzker II fractures with different fracture morphologies. Objectives: To compare the stability of different filler types combined with locked compression plate/screw in different subtypes of Schatzker II TPF. Methods: Four subtypes of Schatzker II were created based on 3D map of TPF. Each of the subtypes was fixed with LCP/screw or LCP/screw combined with different fill types. Stress distribution, displacement distribution, and the load sharing capacity of the filler were assessed by applying the maximum load during gait. In addition, repeated fracture risks of depressed fragment were evaluated regarding to the ultimate strain of bone. Results: The stress concentration of the implant in each scenario was located on the screw at the contact site between the plate and the screw, and the filler of the defect site significantly reduced the stress concentration of the implant (Subtype A: Blank group 402.0 MPa vs. Experimental group 315.2 ± 5.5 MPa; Subtype C: Blank group 385.0 MPa vs. Experimental group 322.7 ± 12.1 MPa). Displacement field analysis showed that filler significantly reduced the reduction loss of the depressed fragment (Subtype A: Blank group 0.1949 mm vs. Experimental group 0.174 ± 0.001 mm; Subtype C: 0.264 mm vs. 0.253 ± 0.002 mm). Maximum strain was in subtype C with the value of 2.3% ± 0.1% indicating the greatest possibility of failure risk. And with the increase of its modulus, the bearing capacity of filler increased. Conclusion: The existence of filler at the defect site can effectively reduce the stress concentration of the implant and the reduction loss of the collapsed block, thus providing good stability for Schatzker II fracture. In subtype A fracture, the modulus of filler presented the slightest influence on the stability, followed by subtype C, while the stability of subtype B was most influenced by the modulus of filler. Therefore, it is necessary to evaluate the preoperative patient imaging data adequately to select the appropriate stiffness of the filler. Frontiers Media S.A. 2022-09-07 /pmc/articles/PMC9490054/ /pubmed/36159683 http://dx.doi.org/10.3389/fbioe.2022.973389 Text en Copyright © 2022 Zeng, Ren, Xu, Hu, Li and Zhang. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Bioengineering and Biotechnology
Zeng, Chuyang
Ren, Xiaomeng
Xu, Cheng
Hu, Mengmeng
Li, Jiantao
Zhang, Wei
Stability of internal fixation systems based on different subtypes of Schatzker II fracture of the tibial plateau: A finite element analysis
title Stability of internal fixation systems based on different subtypes of Schatzker II fracture of the tibial plateau: A finite element analysis
title_full Stability of internal fixation systems based on different subtypes of Schatzker II fracture of the tibial plateau: A finite element analysis
title_fullStr Stability of internal fixation systems based on different subtypes of Schatzker II fracture of the tibial plateau: A finite element analysis
title_full_unstemmed Stability of internal fixation systems based on different subtypes of Schatzker II fracture of the tibial plateau: A finite element analysis
title_short Stability of internal fixation systems based on different subtypes of Schatzker II fracture of the tibial plateau: A finite element analysis
title_sort stability of internal fixation systems based on different subtypes of schatzker ii fracture of the tibial plateau: a finite element analysis
topic Bioengineering and Biotechnology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9490054/
https://www.ncbi.nlm.nih.gov/pubmed/36159683
http://dx.doi.org/10.3389/fbioe.2022.973389
work_keys_str_mv AT zengchuyang stabilityofinternalfixationsystemsbasedondifferentsubtypesofschatzkeriifractureofthetibialplateauafiniteelementanalysis
AT renxiaomeng stabilityofinternalfixationsystemsbasedondifferentsubtypesofschatzkeriifractureofthetibialplateauafiniteelementanalysis
AT xucheng stabilityofinternalfixationsystemsbasedondifferentsubtypesofschatzkeriifractureofthetibialplateauafiniteelementanalysis
AT humengmeng stabilityofinternalfixationsystemsbasedondifferentsubtypesofschatzkeriifractureofthetibialplateauafiniteelementanalysis
AT lijiantao stabilityofinternalfixationsystemsbasedondifferentsubtypesofschatzkeriifractureofthetibialplateauafiniteelementanalysis
AT zhangwei stabilityofinternalfixationsystemsbasedondifferentsubtypesofschatzkeriifractureofthetibialplateauafiniteelementanalysis