Cargando…

Numerical study of magnetic hyperthermia ablation of breast tumor on an anatomically realistic breast phantom

Magnetic fluid hyperthermia (MFH) is a novel reliable technique with excellent potential for thermal therapies and treating breast tumours. This method involves injecting a magnetic nanofluid into the tumour and applying an external AC magnetic field to induce heat in the magnetic nanoparticles (MNP...

Descripción completa

Detalles Bibliográficos
Autores principales: Rahpeima, Reza, Lin, Chao-An
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9491569/
https://www.ncbi.nlm.nih.gov/pubmed/36129953
http://dx.doi.org/10.1371/journal.pone.0274801
_version_ 1784793302911942656
author Rahpeima, Reza
Lin, Chao-An
author_facet Rahpeima, Reza
Lin, Chao-An
author_sort Rahpeima, Reza
collection PubMed
description Magnetic fluid hyperthermia (MFH) is a novel reliable technique with excellent potential for thermal therapies and treating breast tumours. This method involves injecting a magnetic nanofluid into the tumour and applying an external AC magnetic field to induce heat in the magnetic nanoparticles (MNPs) and raise the tumour temperature to ablation temperature ranges. Because of the complexity of considering and coupling all different physics involves in this phenomenon and also due to the intricacy of a thorough FEM numerical study, few FEM-based studies address the entire MFH process as similar to reality as possible. The current study investigates a FEM-based three-dimensional numerical simulation of MFH of breast tumours as a multi-physics problem. An anatomically realistic breast phantom (ARBP) is considered, some magnetic nanofluid is injected inside the tumour, and the diffusion phenomenon is simulated. Then, the amount of heat generated in the MNP-saturated tumour area due to an external AC magnetic field is simulated. In the end, the fraction of tumour tissue necrotized by this temperature rise is evaluated. The study’s results demonstrate that by injecting nanofluid and utilizing seven circular copper windings with each coil carrying 400 A current with a frequency of 400 kHz for generating the external AC magnetic field, the temperature in tumour tissue can be raised to a maximum of about 51.4°C, which leads to necrosis of entire tumour tissue after 30 minutes of electromagnetic field (EMF) exposure. This numerical platform can depict all four various physics involved in the MFH of breast tumours by numerically solving all different equation sets coupled together with high precision. Thus, the proposed model can be utilized by clinicians as a reliable tool for predicting and identifying the approximate amount of temperature rise and the necrotic fraction of breast tumour, which can be very useful to opt for the best MFH therapeutic procedure and conditions based on various patients. In future works, this numerical platform’s results should be compared with experimental in-vivo results to improve and modify this platform in order to be ready for clinical applications.
format Online
Article
Text
id pubmed-9491569
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-94915692022-09-22 Numerical study of magnetic hyperthermia ablation of breast tumor on an anatomically realistic breast phantom Rahpeima, Reza Lin, Chao-An PLoS One Research Article Magnetic fluid hyperthermia (MFH) is a novel reliable technique with excellent potential for thermal therapies and treating breast tumours. This method involves injecting a magnetic nanofluid into the tumour and applying an external AC magnetic field to induce heat in the magnetic nanoparticles (MNPs) and raise the tumour temperature to ablation temperature ranges. Because of the complexity of considering and coupling all different physics involves in this phenomenon and also due to the intricacy of a thorough FEM numerical study, few FEM-based studies address the entire MFH process as similar to reality as possible. The current study investigates a FEM-based three-dimensional numerical simulation of MFH of breast tumours as a multi-physics problem. An anatomically realistic breast phantom (ARBP) is considered, some magnetic nanofluid is injected inside the tumour, and the diffusion phenomenon is simulated. Then, the amount of heat generated in the MNP-saturated tumour area due to an external AC magnetic field is simulated. In the end, the fraction of tumour tissue necrotized by this temperature rise is evaluated. The study’s results demonstrate that by injecting nanofluid and utilizing seven circular copper windings with each coil carrying 400 A current with a frequency of 400 kHz for generating the external AC magnetic field, the temperature in tumour tissue can be raised to a maximum of about 51.4°C, which leads to necrosis of entire tumour tissue after 30 minutes of electromagnetic field (EMF) exposure. This numerical platform can depict all four various physics involved in the MFH of breast tumours by numerically solving all different equation sets coupled together with high precision. Thus, the proposed model can be utilized by clinicians as a reliable tool for predicting and identifying the approximate amount of temperature rise and the necrotic fraction of breast tumour, which can be very useful to opt for the best MFH therapeutic procedure and conditions based on various patients. In future works, this numerical platform’s results should be compared with experimental in-vivo results to improve and modify this platform in order to be ready for clinical applications. Public Library of Science 2022-09-21 /pmc/articles/PMC9491569/ /pubmed/36129953 http://dx.doi.org/10.1371/journal.pone.0274801 Text en © 2022 Rahpeima, Lin https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Rahpeima, Reza
Lin, Chao-An
Numerical study of magnetic hyperthermia ablation of breast tumor on an anatomically realistic breast phantom
title Numerical study of magnetic hyperthermia ablation of breast tumor on an anatomically realistic breast phantom
title_full Numerical study of magnetic hyperthermia ablation of breast tumor on an anatomically realistic breast phantom
title_fullStr Numerical study of magnetic hyperthermia ablation of breast tumor on an anatomically realistic breast phantom
title_full_unstemmed Numerical study of magnetic hyperthermia ablation of breast tumor on an anatomically realistic breast phantom
title_short Numerical study of magnetic hyperthermia ablation of breast tumor on an anatomically realistic breast phantom
title_sort numerical study of magnetic hyperthermia ablation of breast tumor on an anatomically realistic breast phantom
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9491569/
https://www.ncbi.nlm.nih.gov/pubmed/36129953
http://dx.doi.org/10.1371/journal.pone.0274801
work_keys_str_mv AT rahpeimareza numericalstudyofmagnetichyperthermiaablationofbreasttumoronananatomicallyrealisticbreastphantom
AT linchaoan numericalstudyofmagnetichyperthermiaablationofbreasttumoronananatomicallyrealisticbreastphantom