Cargando…
Optic nerve sheath diameter and optic nerve sheath diameter/eyeball transverse diameter ratio in prediction of malignant progression in ischemic stroke
BACKGROUND: The optic nerve sheath diameter (ONSD)/eyeball transverse diameter (ETD) ratio has been suggested in the evaluation of intracranial pressure (ICP). The aim of this study was to evaluate the predictive value of ONSD and ONSD/ETD in relation to risk for secondary malignant middle cerebral...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9493305/ https://www.ncbi.nlm.nih.gov/pubmed/36158954 http://dx.doi.org/10.3389/fneur.2022.998389 |
_version_ | 1784793686606872576 |
---|---|
author | Guo, Yuan Chen, Yinjuan Shen, Chaoxiong Fan, Daofeng Hu, Xiaohong Duan, Jiaojiao Chen, Yangui |
author_facet | Guo, Yuan Chen, Yinjuan Shen, Chaoxiong Fan, Daofeng Hu, Xiaohong Duan, Jiaojiao Chen, Yangui |
author_sort | Guo, Yuan |
collection | PubMed |
description | BACKGROUND: The optic nerve sheath diameter (ONSD)/eyeball transverse diameter (ETD) ratio has been suggested in the evaluation of intracranial pressure (ICP). The aim of this study was to evaluate the predictive value of ONSD and ONSD/ETD in relation to risk for secondary malignant middle cerebral artery infarction (MMI). METHODS: A total of 91 patients with MCA occlusion were included in this study. Data were divided into two groups based on development of MMI or not. ONSD and ETD were measured by unenhanced computed tomography (CT). The differences in ONSD and the ONSD/ETD ratios between the MMI and non-MMI groups were compared. Receiver operating characteristic curve analyses were used to test the diagnostic value of ONSD and ONSD/ETD independently, to predict MMI. RESULTS: The ONSD in the MMI group and non-MMI group were 5.744 ± 0.140 mm and 5.443 ± 0.315 mm, respectively (P = 0.001). In addition, the ONSD/ETD ratios in the MMI group and non-MMI group were 0.258 ± 0.008 and 0.245 ± 0.006, respectively (P = 0.001). The receiver operating characteristic (ROC) curve demonstrated an area under the curve (AUC) for ONSD of 0.812 [95% confidence interval (CI): 0.718–0.906, P = 0.001], with a sensitivity of 97.4% and a specificity of 66.0% at the cut-off value of 5.520 mm. The AUC for ONSD/ETD ratio in predicting occurrence of MMI was 0.895 (95% CI: 0.823–0.968, P = 0.001), with a sensitivity of 84.2% and a specificity of 92.5% at a cut-off value of 0.250. CONCLUSION: In acute stroke patients with massive cerebral infarction, an increased ONSD or ONSD/ETD ratio increases the odds of malignant progression and may be used as an indicator for emergent therapeutic interventions. In addition, the ONSD/ETD ratio may be more valuable than ONSD in predicting the malignant progression of acute stroke patients. |
format | Online Article Text |
id | pubmed-9493305 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-94933052022-09-23 Optic nerve sheath diameter and optic nerve sheath diameter/eyeball transverse diameter ratio in prediction of malignant progression in ischemic stroke Guo, Yuan Chen, Yinjuan Shen, Chaoxiong Fan, Daofeng Hu, Xiaohong Duan, Jiaojiao Chen, Yangui Front Neurol Neurology BACKGROUND: The optic nerve sheath diameter (ONSD)/eyeball transverse diameter (ETD) ratio has been suggested in the evaluation of intracranial pressure (ICP). The aim of this study was to evaluate the predictive value of ONSD and ONSD/ETD in relation to risk for secondary malignant middle cerebral artery infarction (MMI). METHODS: A total of 91 patients with MCA occlusion were included in this study. Data were divided into two groups based on development of MMI or not. ONSD and ETD were measured by unenhanced computed tomography (CT). The differences in ONSD and the ONSD/ETD ratios between the MMI and non-MMI groups were compared. Receiver operating characteristic curve analyses were used to test the diagnostic value of ONSD and ONSD/ETD independently, to predict MMI. RESULTS: The ONSD in the MMI group and non-MMI group were 5.744 ± 0.140 mm and 5.443 ± 0.315 mm, respectively (P = 0.001). In addition, the ONSD/ETD ratios in the MMI group and non-MMI group were 0.258 ± 0.008 and 0.245 ± 0.006, respectively (P = 0.001). The receiver operating characteristic (ROC) curve demonstrated an area under the curve (AUC) for ONSD of 0.812 [95% confidence interval (CI): 0.718–0.906, P = 0.001], with a sensitivity of 97.4% and a specificity of 66.0% at the cut-off value of 5.520 mm. The AUC for ONSD/ETD ratio in predicting occurrence of MMI was 0.895 (95% CI: 0.823–0.968, P = 0.001), with a sensitivity of 84.2% and a specificity of 92.5% at a cut-off value of 0.250. CONCLUSION: In acute stroke patients with massive cerebral infarction, an increased ONSD or ONSD/ETD ratio increases the odds of malignant progression and may be used as an indicator for emergent therapeutic interventions. In addition, the ONSD/ETD ratio may be more valuable than ONSD in predicting the malignant progression of acute stroke patients. Frontiers Media S.A. 2022-09-08 /pmc/articles/PMC9493305/ /pubmed/36158954 http://dx.doi.org/10.3389/fneur.2022.998389 Text en Copyright © 2022 Guo, Chen, Shen, Fan, Hu, Duan and Chen. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Neurology Guo, Yuan Chen, Yinjuan Shen, Chaoxiong Fan, Daofeng Hu, Xiaohong Duan, Jiaojiao Chen, Yangui Optic nerve sheath diameter and optic nerve sheath diameter/eyeball transverse diameter ratio in prediction of malignant progression in ischemic stroke |
title | Optic nerve sheath diameter and optic nerve sheath diameter/eyeball transverse diameter ratio in prediction of malignant progression in ischemic stroke |
title_full | Optic nerve sheath diameter and optic nerve sheath diameter/eyeball transverse diameter ratio in prediction of malignant progression in ischemic stroke |
title_fullStr | Optic nerve sheath diameter and optic nerve sheath diameter/eyeball transverse diameter ratio in prediction of malignant progression in ischemic stroke |
title_full_unstemmed | Optic nerve sheath diameter and optic nerve sheath diameter/eyeball transverse diameter ratio in prediction of malignant progression in ischemic stroke |
title_short | Optic nerve sheath diameter and optic nerve sheath diameter/eyeball transverse diameter ratio in prediction of malignant progression in ischemic stroke |
title_sort | optic nerve sheath diameter and optic nerve sheath diameter/eyeball transverse diameter ratio in prediction of malignant progression in ischemic stroke |
topic | Neurology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9493305/ https://www.ncbi.nlm.nih.gov/pubmed/36158954 http://dx.doi.org/10.3389/fneur.2022.998389 |
work_keys_str_mv | AT guoyuan opticnervesheathdiameterandopticnervesheathdiametereyeballtransversediameterratioinpredictionofmalignantprogressioninischemicstroke AT chenyinjuan opticnervesheathdiameterandopticnervesheathdiametereyeballtransversediameterratioinpredictionofmalignantprogressioninischemicstroke AT shenchaoxiong opticnervesheathdiameterandopticnervesheathdiametereyeballtransversediameterratioinpredictionofmalignantprogressioninischemicstroke AT fandaofeng opticnervesheathdiameterandopticnervesheathdiametereyeballtransversediameterratioinpredictionofmalignantprogressioninischemicstroke AT huxiaohong opticnervesheathdiameterandopticnervesheathdiametereyeballtransversediameterratioinpredictionofmalignantprogressioninischemicstroke AT duanjiaojiao opticnervesheathdiameterandopticnervesheathdiametereyeballtransversediameterratioinpredictionofmalignantprogressioninischemicstroke AT chenyangui opticnervesheathdiameterandopticnervesheathdiametereyeballtransversediameterratioinpredictionofmalignantprogressioninischemicstroke |