Cargando…

High volume retrograde portography for better discrimination of the portal vein during TIPS procedure

Background: Imaging of the portal vein prior to puncture for TIPS is essential. Purpose: With this study, we examined a modified retrograde portography with regard to the reliable representation of the portal vein. Material and Methods: Prospective evaluation of 65 TIPS interventions with regard to...

Descripción completa

Detalles Bibliográficos
Autores principales: Altenbernd, J, Zimmer, S, Andrae, L, Labonte, B, Gruber, J, Beier, H, Abdulgader, M, Buechter, M, Forsting, M, Theysohn, J
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9493682/
https://www.ncbi.nlm.nih.gov/pubmed/36157917
http://dx.doi.org/10.1177/20584601221128405
_version_ 1784793738031136768
author Altenbernd, J
Zimmer, S
Andrae, L
Labonte, B
Gruber, J
Beier, H
Abdulgader, M
Buechter, M
Forsting, M
Theysohn, J
author_facet Altenbernd, J
Zimmer, S
Andrae, L
Labonte, B
Gruber, J
Beier, H
Abdulgader, M
Buechter, M
Forsting, M
Theysohn, J
author_sort Altenbernd, J
collection PubMed
description Background: Imaging of the portal vein prior to puncture for TIPS is essential. Purpose: With this study, we examined a modified retrograde portography with regard to the reliable representation of the portal vein. Material and Methods: Prospective evaluation of 65 TIPS interventions with regard to the delimitation of the portal vein and the exact parameters of retrograde portography such as catheter diameter and contrast medium volume per injection. Results: Retrograde portographies with a large-lumen catheter (10 F) and a large contrast medium volume (40 mL) were performed in 35/63 patients with significantly better delineation of the portal vein than when using 5 F catheters with 10 mL contrast medium. Conclusion: The so-called high volume retrograde portography leads to better delimitation of the portal vein during TIPS application.
format Online
Article
Text
id pubmed-9493682
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-94936822022-09-23 High volume retrograde portography for better discrimination of the portal vein during TIPS procedure Altenbernd, J Zimmer, S Andrae, L Labonte, B Gruber, J Beier, H Abdulgader, M Buechter, M Forsting, M Theysohn, J Acta Radiol Open Original Article Background: Imaging of the portal vein prior to puncture for TIPS is essential. Purpose: With this study, we examined a modified retrograde portography with regard to the reliable representation of the portal vein. Material and Methods: Prospective evaluation of 65 TIPS interventions with regard to the delimitation of the portal vein and the exact parameters of retrograde portography such as catheter diameter and contrast medium volume per injection. Results: Retrograde portographies with a large-lumen catheter (10 F) and a large contrast medium volume (40 mL) were performed in 35/63 patients with significantly better delineation of the portal vein than when using 5 F catheters with 10 mL contrast medium. Conclusion: The so-called high volume retrograde portography leads to better delimitation of the portal vein during TIPS application. SAGE Publications 2022-09-20 /pmc/articles/PMC9493682/ /pubmed/36157917 http://dx.doi.org/10.1177/20584601221128405 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/This article is distributed under the terms of the Creative Commons Attribution 4.0 License (https://creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Article
Altenbernd, J
Zimmer, S
Andrae, L
Labonte, B
Gruber, J
Beier, H
Abdulgader, M
Buechter, M
Forsting, M
Theysohn, J
High volume retrograde portography for better discrimination of the portal vein during TIPS procedure
title High volume retrograde portography for better discrimination of the portal vein during TIPS procedure
title_full High volume retrograde portography for better discrimination of the portal vein during TIPS procedure
title_fullStr High volume retrograde portography for better discrimination of the portal vein during TIPS procedure
title_full_unstemmed High volume retrograde portography for better discrimination of the portal vein during TIPS procedure
title_short High volume retrograde portography for better discrimination of the portal vein during TIPS procedure
title_sort high volume retrograde portography for better discrimination of the portal vein during tips procedure
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9493682/
https://www.ncbi.nlm.nih.gov/pubmed/36157917
http://dx.doi.org/10.1177/20584601221128405
work_keys_str_mv AT altenberndj highvolumeretrogradeportographyforbetterdiscriminationoftheportalveinduringtipsprocedure
AT zimmers highvolumeretrogradeportographyforbetterdiscriminationoftheportalveinduringtipsprocedure
AT andrael highvolumeretrogradeportographyforbetterdiscriminationoftheportalveinduringtipsprocedure
AT labonteb highvolumeretrogradeportographyforbetterdiscriminationoftheportalveinduringtipsprocedure
AT gruberj highvolumeretrogradeportographyforbetterdiscriminationoftheportalveinduringtipsprocedure
AT beierh highvolumeretrogradeportographyforbetterdiscriminationoftheportalveinduringtipsprocedure
AT abdulgaderm highvolumeretrogradeportographyforbetterdiscriminationoftheportalveinduringtipsprocedure
AT buechterm highvolumeretrogradeportographyforbetterdiscriminationoftheportalveinduringtipsprocedure
AT forstingm highvolumeretrogradeportographyforbetterdiscriminationoftheportalveinduringtipsprocedure
AT theysohnj highvolumeretrogradeportographyforbetterdiscriminationoftheportalveinduringtipsprocedure