Cargando…

Green adherent spectrophotometric determination of molnupiravir based on computational calculations; application to a recently FDA-approved pharmaceutical dosage form

Molnupiravir is an oral antiviral drug developed to provide significant benefit in reducing hospitalizations or deaths in mild COVID-19. Integrated green computational spectrophotometric method was developed for the determination of molnupiravir. Theoretical calculations were performed to predict th...

Descripción completa

Detalles Bibliográficos
Autores principales: Abdelazim, Ahmed H., Abourehab, Mohammed A.S., Abd Elhalim, Lobna M., Almrasy, Ahmed A., Ramzy, Sherif
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier B.V. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9494866/
https://www.ncbi.nlm.nih.gov/pubmed/36174404
http://dx.doi.org/10.1016/j.saa.2022.121911
_version_ 1784793884818145280
author Abdelazim, Ahmed H.
Abourehab, Mohammed A.S.
Abd Elhalim, Lobna M.
Almrasy, Ahmed A.
Ramzy, Sherif
author_facet Abdelazim, Ahmed H.
Abourehab, Mohammed A.S.
Abd Elhalim, Lobna M.
Almrasy, Ahmed A.
Ramzy, Sherif
author_sort Abdelazim, Ahmed H.
collection PubMed
description Molnupiravir is an oral antiviral drug developed to provide significant benefit in reducing hospitalizations or deaths in mild COVID-19. Integrated green computational spectrophotometric method was developed for the determination of molnupiravir. Theoretical calculations were performed to predict the best coupling agent for efficient diazo coupling of molnupiravir. The binding energy between molnupiravir and various phenolic coupling agents, α-naphthol, β-naphthol, 8-hydroxyquinoline, resorcinol, and phloroglucinol, was measured using Gaussian 03 software based on the density functional theory method and the basis set B3LYP/6-31G(d). The results showed that the interaction between molnupiravir and 8-hydroxyquinoline was higher than that of other phenolic coupling agents. The method described was based on the formation of a red colored chromogen by the diazo coupling of molnupiravir with sodium nitrite in acidic medium to form a diazonium ion coupled with 8-hydroxyquinoline. The absorption spectra showed maximum sharp peaks at 515 nm. The reaction conditions were optimized. Beer's law was followed over the concentration range of 1–12 μg/ml molnupiravir. Job's continuous variation method was developed and the stoichiometric ratio of molnupiravir to 8-hydroxyquinoline was determined to be 1:1. The described method was successfully applied to the determination of molnupiravir in pure form and in pharmaceutical dosage form. The results showed that the proposed method has minimal environmental impact compared to previous HPLC method.
format Online
Article
Text
id pubmed-9494866
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier B.V.
record_format MEDLINE/PubMed
spelling pubmed-94948662022-09-22 Green adherent spectrophotometric determination of molnupiravir based on computational calculations; application to a recently FDA-approved pharmaceutical dosage form Abdelazim, Ahmed H. Abourehab, Mohammed A.S. Abd Elhalim, Lobna M. Almrasy, Ahmed A. Ramzy, Sherif Spectrochim Acta A Mol Biomol Spectrosc Article Molnupiravir is an oral antiviral drug developed to provide significant benefit in reducing hospitalizations or deaths in mild COVID-19. Integrated green computational spectrophotometric method was developed for the determination of molnupiravir. Theoretical calculations were performed to predict the best coupling agent for efficient diazo coupling of molnupiravir. The binding energy between molnupiravir and various phenolic coupling agents, α-naphthol, β-naphthol, 8-hydroxyquinoline, resorcinol, and phloroglucinol, was measured using Gaussian 03 software based on the density functional theory method and the basis set B3LYP/6-31G(d). The results showed that the interaction between molnupiravir and 8-hydroxyquinoline was higher than that of other phenolic coupling agents. The method described was based on the formation of a red colored chromogen by the diazo coupling of molnupiravir with sodium nitrite in acidic medium to form a diazonium ion coupled with 8-hydroxyquinoline. The absorption spectra showed maximum sharp peaks at 515 nm. The reaction conditions were optimized. Beer's law was followed over the concentration range of 1–12 μg/ml molnupiravir. Job's continuous variation method was developed and the stoichiometric ratio of molnupiravir to 8-hydroxyquinoline was determined to be 1:1. The described method was successfully applied to the determination of molnupiravir in pure form and in pharmaceutical dosage form. The results showed that the proposed method has minimal environmental impact compared to previous HPLC method. Elsevier B.V. 2023-01-15 2022-09-22 /pmc/articles/PMC9494866/ /pubmed/36174404 http://dx.doi.org/10.1016/j.saa.2022.121911 Text en © 2022 Elsevier B.V. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.
spellingShingle Article
Abdelazim, Ahmed H.
Abourehab, Mohammed A.S.
Abd Elhalim, Lobna M.
Almrasy, Ahmed A.
Ramzy, Sherif
Green adherent spectrophotometric determination of molnupiravir based on computational calculations; application to a recently FDA-approved pharmaceutical dosage form
title Green adherent spectrophotometric determination of molnupiravir based on computational calculations; application to a recently FDA-approved pharmaceutical dosage form
title_full Green adherent spectrophotometric determination of molnupiravir based on computational calculations; application to a recently FDA-approved pharmaceutical dosage form
title_fullStr Green adherent spectrophotometric determination of molnupiravir based on computational calculations; application to a recently FDA-approved pharmaceutical dosage form
title_full_unstemmed Green adherent spectrophotometric determination of molnupiravir based on computational calculations; application to a recently FDA-approved pharmaceutical dosage form
title_short Green adherent spectrophotometric determination of molnupiravir based on computational calculations; application to a recently FDA-approved pharmaceutical dosage form
title_sort green adherent spectrophotometric determination of molnupiravir based on computational calculations; application to a recently fda-approved pharmaceutical dosage form
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9494866/
https://www.ncbi.nlm.nih.gov/pubmed/36174404
http://dx.doi.org/10.1016/j.saa.2022.121911
work_keys_str_mv AT abdelazimahmedh greenadherentspectrophotometricdeterminationofmolnupiravirbasedoncomputationalcalculationsapplicationtoarecentlyfdaapprovedpharmaceuticaldosageform
AT abourehabmohammedas greenadherentspectrophotometricdeterminationofmolnupiravirbasedoncomputationalcalculationsapplicationtoarecentlyfdaapprovedpharmaceuticaldosageform
AT abdelhalimlobnam greenadherentspectrophotometricdeterminationofmolnupiravirbasedoncomputationalcalculationsapplicationtoarecentlyfdaapprovedpharmaceuticaldosageform
AT almrasyahmeda greenadherentspectrophotometricdeterminationofmolnupiravirbasedoncomputationalcalculationsapplicationtoarecentlyfdaapprovedpharmaceuticaldosageform
AT ramzysherif greenadherentspectrophotometricdeterminationofmolnupiravirbasedoncomputationalcalculationsapplicationtoarecentlyfdaapprovedpharmaceuticaldosageform