Cargando…

End-to-End Convolutional Neural Network Model to Detect and Localize Myocardial Infarction Using 12-Lead ECG Images without Preprocessing

In recent years, many studies have proposed automatic detection and localization techniques for myocardial infarction (MI) using the 12-lead electrocardiogram (ECG). Most of them applied preprocessing to the ECG signals, e.g., noise removal, trend removal, beat segmentation, and feature selection, f...

Descripción completa

Detalles Bibliográficos
Autores principales: Uchiyama, Ryunosuke, Okada, Yoshifumi, Kakizaki, Ryuya, Tomioka, Sekito
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9495488/
https://www.ncbi.nlm.nih.gov/pubmed/36134976
http://dx.doi.org/10.3390/bioengineering9090430
_version_ 1784794030982299648
author Uchiyama, Ryunosuke
Okada, Yoshifumi
Kakizaki, Ryuya
Tomioka, Sekito
author_facet Uchiyama, Ryunosuke
Okada, Yoshifumi
Kakizaki, Ryuya
Tomioka, Sekito
author_sort Uchiyama, Ryunosuke
collection PubMed
description In recent years, many studies have proposed automatic detection and localization techniques for myocardial infarction (MI) using the 12-lead electrocardiogram (ECG). Most of them applied preprocessing to the ECG signals, e.g., noise removal, trend removal, beat segmentation, and feature selection, followed by model construction and classification based on machine-learning algorithms. The selection and implementation of preprocessing methods require specialized knowledge and experience to handle ECG data. In this paper, we propose an end-to-end convolutional neural network model that detects and localizes MI without such complicated multistep preprocessing. The proposed model executes comprehensive learning for the waveform features of unpreprocessed raw ECG images captured from 12-lead ECG signals. We evaluated the classification performance of the proposed model in two experimental settings: ten-fold cross-validation where ECG images were split randomly, and two-fold cross-validation where ECG images were split into one patient and the other patients. The experimental results demonstrate that the proposed model obtained MI detection accuracies of 99.82% and 93.93% and MI localization accuracies of 99.28% and 69.27% in the first and second settings, respectively. The performance of the proposed method is higher than or comparable to that of existing state-of-the-art methods. Thus, the proposed model is expected to be an effective MI diagnosis tool that can be used in intensive care units and as wearable technology.
format Online
Article
Text
id pubmed-9495488
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-94954882022-09-23 End-to-End Convolutional Neural Network Model to Detect and Localize Myocardial Infarction Using 12-Lead ECG Images without Preprocessing Uchiyama, Ryunosuke Okada, Yoshifumi Kakizaki, Ryuya Tomioka, Sekito Bioengineering (Basel) Article In recent years, many studies have proposed automatic detection and localization techniques for myocardial infarction (MI) using the 12-lead electrocardiogram (ECG). Most of them applied preprocessing to the ECG signals, e.g., noise removal, trend removal, beat segmentation, and feature selection, followed by model construction and classification based on machine-learning algorithms. The selection and implementation of preprocessing methods require specialized knowledge and experience to handle ECG data. In this paper, we propose an end-to-end convolutional neural network model that detects and localizes MI without such complicated multistep preprocessing. The proposed model executes comprehensive learning for the waveform features of unpreprocessed raw ECG images captured from 12-lead ECG signals. We evaluated the classification performance of the proposed model in two experimental settings: ten-fold cross-validation where ECG images were split randomly, and two-fold cross-validation where ECG images were split into one patient and the other patients. The experimental results demonstrate that the proposed model obtained MI detection accuracies of 99.82% and 93.93% and MI localization accuracies of 99.28% and 69.27% in the first and second settings, respectively. The performance of the proposed method is higher than or comparable to that of existing state-of-the-art methods. Thus, the proposed model is expected to be an effective MI diagnosis tool that can be used in intensive care units and as wearable technology. MDPI 2022-09-01 /pmc/articles/PMC9495488/ /pubmed/36134976 http://dx.doi.org/10.3390/bioengineering9090430 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Uchiyama, Ryunosuke
Okada, Yoshifumi
Kakizaki, Ryuya
Tomioka, Sekito
End-to-End Convolutional Neural Network Model to Detect and Localize Myocardial Infarction Using 12-Lead ECG Images without Preprocessing
title End-to-End Convolutional Neural Network Model to Detect and Localize Myocardial Infarction Using 12-Lead ECG Images without Preprocessing
title_full End-to-End Convolutional Neural Network Model to Detect and Localize Myocardial Infarction Using 12-Lead ECG Images without Preprocessing
title_fullStr End-to-End Convolutional Neural Network Model to Detect and Localize Myocardial Infarction Using 12-Lead ECG Images without Preprocessing
title_full_unstemmed End-to-End Convolutional Neural Network Model to Detect and Localize Myocardial Infarction Using 12-Lead ECG Images without Preprocessing
title_short End-to-End Convolutional Neural Network Model to Detect and Localize Myocardial Infarction Using 12-Lead ECG Images without Preprocessing
title_sort end-to-end convolutional neural network model to detect and localize myocardial infarction using 12-lead ecg images without preprocessing
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9495488/
https://www.ncbi.nlm.nih.gov/pubmed/36134976
http://dx.doi.org/10.3390/bioengineering9090430
work_keys_str_mv AT uchiyamaryunosuke endtoendconvolutionalneuralnetworkmodeltodetectandlocalizemyocardialinfarctionusing12leadecgimageswithoutpreprocessing
AT okadayoshifumi endtoendconvolutionalneuralnetworkmodeltodetectandlocalizemyocardialinfarctionusing12leadecgimageswithoutpreprocessing
AT kakizakiryuya endtoendconvolutionalneuralnetworkmodeltodetectandlocalizemyocardialinfarctionusing12leadecgimageswithoutpreprocessing
AT tomiokasekito endtoendconvolutionalneuralnetworkmodeltodetectandlocalizemyocardialinfarctionusing12leadecgimageswithoutpreprocessing