Cargando…

Evaluation of a Locking Autocompression Screw Model in Pauwels Type-3 Femoral Neck Fracture: In Vitro Analysis

Femoral neck fractures in young adults are uncommon, resulting from high-energy trauma. Despite their infrequency in this population, there is higher rate of complications, especially in the more vertical fracture line, classified by Pauwels as a type-3 femoral neck fracture. The implant type is of...

Descripción completa

Detalles Bibliográficos
Autores principales: Giordano, Vincenzo, Freitas, Anderson, Pires, Robinson Esteves, Battaglion, Leonardo Rigobello, Lobo, Mariana de Oliveira, Belangero, William Dias
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9495566/
https://www.ncbi.nlm.nih.gov/pubmed/36135010
http://dx.doi.org/10.3390/bioengineering9090464
_version_ 1784794049738178560
author Giordano, Vincenzo
Freitas, Anderson
Pires, Robinson Esteves
Battaglion, Leonardo Rigobello
Lobo, Mariana de Oliveira
Belangero, William Dias
author_facet Giordano, Vincenzo
Freitas, Anderson
Pires, Robinson Esteves
Battaglion, Leonardo Rigobello
Lobo, Mariana de Oliveira
Belangero, William Dias
author_sort Giordano, Vincenzo
collection PubMed
description Femoral neck fractures in young adults are uncommon, resulting from high-energy trauma. Despite their infrequency in this population, there is higher rate of complications, especially in the more vertical fracture line, classified by Pauwels as a type-3 femoral neck fracture. The implant type is of paramount importance for maintaining anatomical reduction, since it must resist the deforming forces that act on the fracture. We comparatively evaluated two constructions of the novel locking autocompression implant (X-PIN and X-PIN+P) using the finite element method and previously established methods for treating Pauwels type-3 femoral neck fractures. Six fixation models were developed for the study: a dynamic hip screw (DHS), a DHS with an anti-rotation screw (DHS+P), the inverted triangle multiple cannulated screws construction (ASNIS), the multiple cannulated screws in an L-configuration (L), and the two models of the novel locking autocompression screw (X-PIN and X-PIN+P). Under the same conditions with a load of 2100 N, the following parameters were evaluated using SIMLAB(®) software: the main maximum (Max P), main minimum (Min P), localized maximum P1 (Max P1), localized maximum P2 (Max P2), total displacement, localized displacement, rotation displacement, and von Mises stress. Compared to the DHS+P and ASNIS models, the X-PIN+P model presented, respectively, increases of 51.6% and 64.7% for Max P, 85% and 247% for Min P, and 18.9% and 166.7% for von Mises stress. Max P1 did not differ between the models, but Max P2 was 55% and 50% lower for X-PIN+P than ASNIS and L, respectively. All displacement values were lower for X-PIN+P than the other models. In this FEM testing, the X-PIN+P was superior to the other models, which was due to improvement in all parameters of stress distribution, displacement, and von Mises stress compared to models using a lateral plate (DHS and DHS+P) or not (ASNIS and L).
format Online
Article
Text
id pubmed-9495566
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-94955662022-09-23 Evaluation of a Locking Autocompression Screw Model in Pauwels Type-3 Femoral Neck Fracture: In Vitro Analysis Giordano, Vincenzo Freitas, Anderson Pires, Robinson Esteves Battaglion, Leonardo Rigobello Lobo, Mariana de Oliveira Belangero, William Dias Bioengineering (Basel) Article Femoral neck fractures in young adults are uncommon, resulting from high-energy trauma. Despite their infrequency in this population, there is higher rate of complications, especially in the more vertical fracture line, classified by Pauwels as a type-3 femoral neck fracture. The implant type is of paramount importance for maintaining anatomical reduction, since it must resist the deforming forces that act on the fracture. We comparatively evaluated two constructions of the novel locking autocompression implant (X-PIN and X-PIN+P) using the finite element method and previously established methods for treating Pauwels type-3 femoral neck fractures. Six fixation models were developed for the study: a dynamic hip screw (DHS), a DHS with an anti-rotation screw (DHS+P), the inverted triangle multiple cannulated screws construction (ASNIS), the multiple cannulated screws in an L-configuration (L), and the two models of the novel locking autocompression screw (X-PIN and X-PIN+P). Under the same conditions with a load of 2100 N, the following parameters were evaluated using SIMLAB(®) software: the main maximum (Max P), main minimum (Min P), localized maximum P1 (Max P1), localized maximum P2 (Max P2), total displacement, localized displacement, rotation displacement, and von Mises stress. Compared to the DHS+P and ASNIS models, the X-PIN+P model presented, respectively, increases of 51.6% and 64.7% for Max P, 85% and 247% for Min P, and 18.9% and 166.7% for von Mises stress. Max P1 did not differ between the models, but Max P2 was 55% and 50% lower for X-PIN+P than ASNIS and L, respectively. All displacement values were lower for X-PIN+P than the other models. In this FEM testing, the X-PIN+P was superior to the other models, which was due to improvement in all parameters of stress distribution, displacement, and von Mises stress compared to models using a lateral plate (DHS and DHS+P) or not (ASNIS and L). MDPI 2022-09-12 /pmc/articles/PMC9495566/ /pubmed/36135010 http://dx.doi.org/10.3390/bioengineering9090464 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Giordano, Vincenzo
Freitas, Anderson
Pires, Robinson Esteves
Battaglion, Leonardo Rigobello
Lobo, Mariana de Oliveira
Belangero, William Dias
Evaluation of a Locking Autocompression Screw Model in Pauwels Type-3 Femoral Neck Fracture: In Vitro Analysis
title Evaluation of a Locking Autocompression Screw Model in Pauwels Type-3 Femoral Neck Fracture: In Vitro Analysis
title_full Evaluation of a Locking Autocompression Screw Model in Pauwels Type-3 Femoral Neck Fracture: In Vitro Analysis
title_fullStr Evaluation of a Locking Autocompression Screw Model in Pauwels Type-3 Femoral Neck Fracture: In Vitro Analysis
title_full_unstemmed Evaluation of a Locking Autocompression Screw Model in Pauwels Type-3 Femoral Neck Fracture: In Vitro Analysis
title_short Evaluation of a Locking Autocompression Screw Model in Pauwels Type-3 Femoral Neck Fracture: In Vitro Analysis
title_sort evaluation of a locking autocompression screw model in pauwels type-3 femoral neck fracture: in vitro analysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9495566/
https://www.ncbi.nlm.nih.gov/pubmed/36135010
http://dx.doi.org/10.3390/bioengineering9090464
work_keys_str_mv AT giordanovincenzo evaluationofalockingautocompressionscrewmodelinpauwelstype3femoralneckfractureinvitroanalysis
AT freitasanderson evaluationofalockingautocompressionscrewmodelinpauwelstype3femoralneckfractureinvitroanalysis
AT piresrobinsonesteves evaluationofalockingautocompressionscrewmodelinpauwelstype3femoralneckfractureinvitroanalysis
AT battaglionleonardorigobello evaluationofalockingautocompressionscrewmodelinpauwelstype3femoralneckfractureinvitroanalysis
AT lobomarianadeoliveira evaluationofalockingautocompressionscrewmodelinpauwelstype3femoralneckfractureinvitroanalysis
AT belangerowilliamdias evaluationofalockingautocompressionscrewmodelinpauwelstype3femoralneckfractureinvitroanalysis