Cargando…

Comparison of Wear of Interim Crowns in Accordance with the Build Angle of Digital Light Processing 3D Printing: A Preliminary In Vivo Study

The aim of this study is to evaluate the wear volume of interim crowns fabricated using digital light processing 3D printing according to the printing angle. A total of five patients undergoing the placement of a single crown on the mandibular molar were included. Interim crowns were fabricated dire...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Hakjun, Son, Keunbada, Lee, Du-Hyeong, Kim, So-Yeun, Lee, Kyu-Bok
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9495768/
https://www.ncbi.nlm.nih.gov/pubmed/36134963
http://dx.doi.org/10.3390/bioengineering9090417
_version_ 1784794100474576896
author Lee, Hakjun
Son, Keunbada
Lee, Du-Hyeong
Kim, So-Yeun
Lee, Kyu-Bok
author_facet Lee, Hakjun
Son, Keunbada
Lee, Du-Hyeong
Kim, So-Yeun
Lee, Kyu-Bok
author_sort Lee, Hakjun
collection PubMed
description The aim of this study is to evaluate the wear volume of interim crowns fabricated using digital light processing 3D printing according to the printing angle. A total of five patients undergoing the placement of a single crown on the mandibular molar were included. Interim crowns were fabricated directly in the oral cavity using the conventional method. A digital light processing 3D printer was then used to fabricate crowns with build angles of 0, 45, and 90 degrees. Therefore, four fabricated interim crowns were randomly delivered to the patients, and each was used for one week. Before and after use, the intaglio surfaces of the interim crowns were scanned using a 3D scanner. The volume changes before and after use were measured, and changes in the height of the occlusal surface were evaluated using the root mean square value. Data normality was verified by statistical analysis, and the wear volume in each group was evaluated using a one-way analysis of variance and Tukey’s honestly significant difference test (α = 0.05). Compared with the RMS values of the conventional method (11.88 ± 2.69 µm) and the 3D-printing method at 0 degrees (12.14 ± 2.38 µm), the RMS values were significantly high at 90 degrees (16.46 ± 2.39 µm) (p < 0.05). Likewise, there was a significant difference in the change in volume between the groups (p = 0.002), with a significantly higher volume change value at 90 degrees (1.74 ± 0.41 mm(3)) than in the conventional method (0.70 ± 0.15 mm(3)) (p < 0.05). A printing angle of 90 degrees is not recommended when interim crowns are fabricated using digital light processing 3D printing.
format Online
Article
Text
id pubmed-9495768
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-94957682022-09-23 Comparison of Wear of Interim Crowns in Accordance with the Build Angle of Digital Light Processing 3D Printing: A Preliminary In Vivo Study Lee, Hakjun Son, Keunbada Lee, Du-Hyeong Kim, So-Yeun Lee, Kyu-Bok Bioengineering (Basel) Article The aim of this study is to evaluate the wear volume of interim crowns fabricated using digital light processing 3D printing according to the printing angle. A total of five patients undergoing the placement of a single crown on the mandibular molar were included. Interim crowns were fabricated directly in the oral cavity using the conventional method. A digital light processing 3D printer was then used to fabricate crowns with build angles of 0, 45, and 90 degrees. Therefore, four fabricated interim crowns were randomly delivered to the patients, and each was used for one week. Before and after use, the intaglio surfaces of the interim crowns were scanned using a 3D scanner. The volume changes before and after use were measured, and changes in the height of the occlusal surface were evaluated using the root mean square value. Data normality was verified by statistical analysis, and the wear volume in each group was evaluated using a one-way analysis of variance and Tukey’s honestly significant difference test (α = 0.05). Compared with the RMS values of the conventional method (11.88 ± 2.69 µm) and the 3D-printing method at 0 degrees (12.14 ± 2.38 µm), the RMS values were significantly high at 90 degrees (16.46 ± 2.39 µm) (p < 0.05). Likewise, there was a significant difference in the change in volume between the groups (p = 0.002), with a significantly higher volume change value at 90 degrees (1.74 ± 0.41 mm(3)) than in the conventional method (0.70 ± 0.15 mm(3)) (p < 0.05). A printing angle of 90 degrees is not recommended when interim crowns are fabricated using digital light processing 3D printing. MDPI 2022-08-25 /pmc/articles/PMC9495768/ /pubmed/36134963 http://dx.doi.org/10.3390/bioengineering9090417 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lee, Hakjun
Son, Keunbada
Lee, Du-Hyeong
Kim, So-Yeun
Lee, Kyu-Bok
Comparison of Wear of Interim Crowns in Accordance with the Build Angle of Digital Light Processing 3D Printing: A Preliminary In Vivo Study
title Comparison of Wear of Interim Crowns in Accordance with the Build Angle of Digital Light Processing 3D Printing: A Preliminary In Vivo Study
title_full Comparison of Wear of Interim Crowns in Accordance with the Build Angle of Digital Light Processing 3D Printing: A Preliminary In Vivo Study
title_fullStr Comparison of Wear of Interim Crowns in Accordance with the Build Angle of Digital Light Processing 3D Printing: A Preliminary In Vivo Study
title_full_unstemmed Comparison of Wear of Interim Crowns in Accordance with the Build Angle of Digital Light Processing 3D Printing: A Preliminary In Vivo Study
title_short Comparison of Wear of Interim Crowns in Accordance with the Build Angle of Digital Light Processing 3D Printing: A Preliminary In Vivo Study
title_sort comparison of wear of interim crowns in accordance with the build angle of digital light processing 3d printing: a preliminary in vivo study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9495768/
https://www.ncbi.nlm.nih.gov/pubmed/36134963
http://dx.doi.org/10.3390/bioengineering9090417
work_keys_str_mv AT leehakjun comparisonofwearofinterimcrownsinaccordancewiththebuildangleofdigitallightprocessing3dprintingapreliminaryinvivostudy
AT sonkeunbada comparisonofwearofinterimcrownsinaccordancewiththebuildangleofdigitallightprocessing3dprintingapreliminaryinvivostudy
AT leeduhyeong comparisonofwearofinterimcrownsinaccordancewiththebuildangleofdigitallightprocessing3dprintingapreliminaryinvivostudy
AT kimsoyeun comparisonofwearofinterimcrownsinaccordancewiththebuildangleofdigitallightprocessing3dprintingapreliminaryinvivostudy
AT leekyubok comparisonofwearofinterimcrownsinaccordancewiththebuildangleofdigitallightprocessing3dprintingapreliminaryinvivostudy