Influence of Pre-Treatment and Artificial Aging on the Retention of 3D-Printed Permanent Composite Crowns
The aim of this in vitro study is to investigate the bonding properties of a 3D-printable permanent composite material in comparison to milled composite materials. The tested materials are 3D-printed BEGO VarseoSmile Crown (plus) (VA1_ab, VA1_nt, VA2_ab, VA2_nt), Vita Enamic (EN1, EN2), and 3M Lava...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9496133/ https://www.ncbi.nlm.nih.gov/pubmed/36140287 http://dx.doi.org/10.3390/biomedicines10092186 |
_version_ | 1784794193992876032 |
---|---|
author | Graf, Tobias Erdelt, Kurt-Jürgen Güth, Jan-Frederik Edelhoff, Daniel Schubert, Oliver Schweiger, Josef |
author_facet | Graf, Tobias Erdelt, Kurt-Jürgen Güth, Jan-Frederik Edelhoff, Daniel Schubert, Oliver Schweiger, Josef |
author_sort | Graf, Tobias |
collection | PubMed |
description | The aim of this in vitro study is to investigate the bonding properties of a 3D-printable permanent composite material in comparison to milled composite materials. The tested materials are 3D-printed BEGO VarseoSmile Crown (plus) (VA1_ab, VA1_nt, VA2_ab, VA2_nt), Vita Enamic (EN1, EN2), and 3M Lava Ultimate (UL1, UL2) (N = 64; n = 8). For this purpose, all crowns are luted to polymer tooth stumps #46 (FDI) using dual-curing luting composite, strictly according to the manufacturer’s instructions. VA1_ab and VA2_ab are additionally airborne-particle abraded. 4 groups (VA2_ab, VA2_nt, EN2, UL2) are artificially aged (1,200,000 cycles, 50 N, 10,000 thermocycles), whereby no specimen has failed. All 64 specimens undergo pull-off testing until retention loss. The mean forces of retention-loss is 786.6 ± 137.6 N (VA1_nt, *), 988.6 ± 212.1 N (VA2_nt, *, Ɨ), 1223.8 ± 119.2 N (VA1_ab, Ɨ, ǂ), 1051.9 ± 107.2 N (VA2_ab, *, Ɨ), 1185.9 ± 211.8 N (EN1, Ɨ, ǂ), 1485.0 ± 198.2 N EN2, ǂ), 1533.8 ± 42.4 N (UL1, ǂ), and 1521.8 ± 343.4 N (UL2, ǂ) (one-way ANOVA (Scheffé method); p < 0.05; *, Ɨ, ǂ: group distribution). No characteristic failure modes can be detected. In conclusion, all of the pull-off forces reflect retention values that seem to be sufficiently high for clinical use. Additional airborne-particle abrasion of VA does not result in significantly better retention but can be recommended. |
format | Online Article Text |
id | pubmed-9496133 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-94961332022-09-23 Influence of Pre-Treatment and Artificial Aging on the Retention of 3D-Printed Permanent Composite Crowns Graf, Tobias Erdelt, Kurt-Jürgen Güth, Jan-Frederik Edelhoff, Daniel Schubert, Oliver Schweiger, Josef Biomedicines Article The aim of this in vitro study is to investigate the bonding properties of a 3D-printable permanent composite material in comparison to milled composite materials. The tested materials are 3D-printed BEGO VarseoSmile Crown (plus) (VA1_ab, VA1_nt, VA2_ab, VA2_nt), Vita Enamic (EN1, EN2), and 3M Lava Ultimate (UL1, UL2) (N = 64; n = 8). For this purpose, all crowns are luted to polymer tooth stumps #46 (FDI) using dual-curing luting composite, strictly according to the manufacturer’s instructions. VA1_ab and VA2_ab are additionally airborne-particle abraded. 4 groups (VA2_ab, VA2_nt, EN2, UL2) are artificially aged (1,200,000 cycles, 50 N, 10,000 thermocycles), whereby no specimen has failed. All 64 specimens undergo pull-off testing until retention loss. The mean forces of retention-loss is 786.6 ± 137.6 N (VA1_nt, *), 988.6 ± 212.1 N (VA2_nt, *, Ɨ), 1223.8 ± 119.2 N (VA1_ab, Ɨ, ǂ), 1051.9 ± 107.2 N (VA2_ab, *, Ɨ), 1185.9 ± 211.8 N (EN1, Ɨ, ǂ), 1485.0 ± 198.2 N EN2, ǂ), 1533.8 ± 42.4 N (UL1, ǂ), and 1521.8 ± 343.4 N (UL2, ǂ) (one-way ANOVA (Scheffé method); p < 0.05; *, Ɨ, ǂ: group distribution). No characteristic failure modes can be detected. In conclusion, all of the pull-off forces reflect retention values that seem to be sufficiently high for clinical use. Additional airborne-particle abrasion of VA does not result in significantly better retention but can be recommended. MDPI 2022-09-04 /pmc/articles/PMC9496133/ /pubmed/36140287 http://dx.doi.org/10.3390/biomedicines10092186 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Graf, Tobias Erdelt, Kurt-Jürgen Güth, Jan-Frederik Edelhoff, Daniel Schubert, Oliver Schweiger, Josef Influence of Pre-Treatment and Artificial Aging on the Retention of 3D-Printed Permanent Composite Crowns |
title | Influence of Pre-Treatment and Artificial Aging on the Retention of 3D-Printed Permanent Composite Crowns |
title_full | Influence of Pre-Treatment and Artificial Aging on the Retention of 3D-Printed Permanent Composite Crowns |
title_fullStr | Influence of Pre-Treatment and Artificial Aging on the Retention of 3D-Printed Permanent Composite Crowns |
title_full_unstemmed | Influence of Pre-Treatment and Artificial Aging on the Retention of 3D-Printed Permanent Composite Crowns |
title_short | Influence of Pre-Treatment and Artificial Aging on the Retention of 3D-Printed Permanent Composite Crowns |
title_sort | influence of pre-treatment and artificial aging on the retention of 3d-printed permanent composite crowns |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9496133/ https://www.ncbi.nlm.nih.gov/pubmed/36140287 http://dx.doi.org/10.3390/biomedicines10092186 |
work_keys_str_mv | AT graftobias influenceofpretreatmentandartificialagingontheretentionof3dprintedpermanentcompositecrowns AT erdeltkurtjurgen influenceofpretreatmentandartificialagingontheretentionof3dprintedpermanentcompositecrowns AT guthjanfrederik influenceofpretreatmentandartificialagingontheretentionof3dprintedpermanentcompositecrowns AT edelhoffdaniel influenceofpretreatmentandartificialagingontheretentionof3dprintedpermanentcompositecrowns AT schubertoliver influenceofpretreatmentandartificialagingontheretentionof3dprintedpermanentcompositecrowns AT schweigerjosef influenceofpretreatmentandartificialagingontheretentionof3dprintedpermanentcompositecrowns |