Feasibility of Blood Pressure Measurement With a Wearable (Watch‐Type) Monitor During Impending Syncopal Episodes

BACKGROUND: We assessed the reliability and feasibility of blood pressure (BP) measurements by means of a new wearable watch‐type BP monitor (HeartGuide) in detecting episodes of hypotensive (pre)syncope induced by tilt table test. METHODS AND RESULTS: An intrapatient comparison between systolic BP...

Descripción completa

Detalles Bibliográficos
Autores principales: Groppelli, Antonella, Rafanelli, Martina, Testa, Giuseppe Dario, Agusto, Samuele, Rivasi, Giulia, Ungar, Andrea, Carbone, Erika, Soranna, Davide, Zambon, Antonella, Brignole, Michele, Parati, Gianfranco
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9496316/
https://www.ncbi.nlm.nih.gov/pubmed/35929469
http://dx.doi.org/10.1161/JAHA.122.026420
_version_ 1784794238839422976
author Groppelli, Antonella
Rafanelli, Martina
Testa, Giuseppe Dario
Agusto, Samuele
Rivasi, Giulia
Ungar, Andrea
Carbone, Erika
Soranna, Davide
Zambon, Antonella
Brignole, Michele
Parati, Gianfranco
author_facet Groppelli, Antonella
Rafanelli, Martina
Testa, Giuseppe Dario
Agusto, Samuele
Rivasi, Giulia
Ungar, Andrea
Carbone, Erika
Soranna, Davide
Zambon, Antonella
Brignole, Michele
Parati, Gianfranco
author_sort Groppelli, Antonella
collection PubMed
description BACKGROUND: We assessed the reliability and feasibility of blood pressure (BP) measurements by means of a new wearable watch‐type BP monitor (HeartGuide) in detecting episodes of hypotensive (pre)syncope induced by tilt table test. METHODS AND RESULTS: An intrapatient comparison between systolic BP (SBP) measured by means of the HeartGuide device and noninvasive finger beat‐to‐beat BP monitoring was undertaken both at baseline in supine position and repeatedly during tilt table test in patients evaluated for reflex syncope. Intrapatient fall of systolic BP from baseline was measured. Eighty‐one patients (mean age, 61±19 years; 46 women) were included. Overall, HeartGuide was able to yield BP values at the time of BP nadir in 58 (72%) patients (average HeartGuide SBP 102±18 mm Hg, versus finger SBP 101±19 mm Hg). Compared with baseline, the maximum SBP decrease was on average −28.5±27.8 and −30.3±33.9 mm Hg respectively (Lin's concordance correlation coefficient=0.78, r=0.79, P=0.001). In the subgroup of 38 patients with tilt table test induced (pre)syncope, the average HeartGuide SBP during symptoms was 97±16 mm Hg, and the finger SBP was 94±18 mm Hg. Compared with baseline, the maximum SBP decrease was on average −35.2±29.3 and −43.3±31.8 mm Hg, respectively (Lin's concordance correlation coefficient=0.83, r=0.87, P=0.001). CONCLUSIONS: Our data indicate that the HeartGuide BP monitor can detect low BP during presyncope and that its measure of SBP change is consistent with that simultaneously obtained through continuous BP monitoring, despite some intrapatient variability. Thus, this device might be useful in determining the hypotensive nature of spontaneous (pre)syncopal symptoms, a possibility that should be verified by field studies.
format Online
Article
Text
id pubmed-9496316
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-94963162022-09-30 Feasibility of Blood Pressure Measurement With a Wearable (Watch‐Type) Monitor During Impending Syncopal Episodes Groppelli, Antonella Rafanelli, Martina Testa, Giuseppe Dario Agusto, Samuele Rivasi, Giulia Ungar, Andrea Carbone, Erika Soranna, Davide Zambon, Antonella Brignole, Michele Parati, Gianfranco J Am Heart Assoc Original Research BACKGROUND: We assessed the reliability and feasibility of blood pressure (BP) measurements by means of a new wearable watch‐type BP monitor (HeartGuide) in detecting episodes of hypotensive (pre)syncope induced by tilt table test. METHODS AND RESULTS: An intrapatient comparison between systolic BP (SBP) measured by means of the HeartGuide device and noninvasive finger beat‐to‐beat BP monitoring was undertaken both at baseline in supine position and repeatedly during tilt table test in patients evaluated for reflex syncope. Intrapatient fall of systolic BP from baseline was measured. Eighty‐one patients (mean age, 61±19 years; 46 women) were included. Overall, HeartGuide was able to yield BP values at the time of BP nadir in 58 (72%) patients (average HeartGuide SBP 102±18 mm Hg, versus finger SBP 101±19 mm Hg). Compared with baseline, the maximum SBP decrease was on average −28.5±27.8 and −30.3±33.9 mm Hg respectively (Lin's concordance correlation coefficient=0.78, r=0.79, P=0.001). In the subgroup of 38 patients with tilt table test induced (pre)syncope, the average HeartGuide SBP during symptoms was 97±16 mm Hg, and the finger SBP was 94±18 mm Hg. Compared with baseline, the maximum SBP decrease was on average −35.2±29.3 and −43.3±31.8 mm Hg, respectively (Lin's concordance correlation coefficient=0.83, r=0.87, P=0.001). CONCLUSIONS: Our data indicate that the HeartGuide BP monitor can detect low BP during presyncope and that its measure of SBP change is consistent with that simultaneously obtained through continuous BP monitoring, despite some intrapatient variability. Thus, this device might be useful in determining the hypotensive nature of spontaneous (pre)syncopal symptoms, a possibility that should be verified by field studies. John Wiley and Sons Inc. 2022-08-05 /pmc/articles/PMC9496316/ /pubmed/35929469 http://dx.doi.org/10.1161/JAHA.122.026420 Text en © 2022 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Original Research
Groppelli, Antonella
Rafanelli, Martina
Testa, Giuseppe Dario
Agusto, Samuele
Rivasi, Giulia
Ungar, Andrea
Carbone, Erika
Soranna, Davide
Zambon, Antonella
Brignole, Michele
Parati, Gianfranco
Feasibility of Blood Pressure Measurement With a Wearable (Watch‐Type) Monitor During Impending Syncopal Episodes
title Feasibility of Blood Pressure Measurement With a Wearable (Watch‐Type) Monitor During Impending Syncopal Episodes
title_full Feasibility of Blood Pressure Measurement With a Wearable (Watch‐Type) Monitor During Impending Syncopal Episodes
title_fullStr Feasibility of Blood Pressure Measurement With a Wearable (Watch‐Type) Monitor During Impending Syncopal Episodes
title_full_unstemmed Feasibility of Blood Pressure Measurement With a Wearable (Watch‐Type) Monitor During Impending Syncopal Episodes
title_short Feasibility of Blood Pressure Measurement With a Wearable (Watch‐Type) Monitor During Impending Syncopal Episodes
title_sort feasibility of blood pressure measurement with a wearable (watch‐type) monitor during impending syncopal episodes
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9496316/
https://www.ncbi.nlm.nih.gov/pubmed/35929469
http://dx.doi.org/10.1161/JAHA.122.026420
work_keys_str_mv AT groppelliantonella feasibilityofbloodpressuremeasurementwithawearablewatchtypemonitorduringimpendingsyncopalepisodes
AT rafanellimartina feasibilityofbloodpressuremeasurementwithawearablewatchtypemonitorduringimpendingsyncopalepisodes
AT testagiuseppedario feasibilityofbloodpressuremeasurementwithawearablewatchtypemonitorduringimpendingsyncopalepisodes
AT agustosamuele feasibilityofbloodpressuremeasurementwithawearablewatchtypemonitorduringimpendingsyncopalepisodes
AT rivasigiulia feasibilityofbloodpressuremeasurementwithawearablewatchtypemonitorduringimpendingsyncopalepisodes
AT ungarandrea feasibilityofbloodpressuremeasurementwithawearablewatchtypemonitorduringimpendingsyncopalepisodes
AT carboneerika feasibilityofbloodpressuremeasurementwithawearablewatchtypemonitorduringimpendingsyncopalepisodes
AT sorannadavide feasibilityofbloodpressuremeasurementwithawearablewatchtypemonitorduringimpendingsyncopalepisodes
AT zambonantonella feasibilityofbloodpressuremeasurementwithawearablewatchtypemonitorduringimpendingsyncopalepisodes
AT brignolemichele feasibilityofbloodpressuremeasurementwithawearablewatchtypemonitorduringimpendingsyncopalepisodes
AT paratigianfranco feasibilityofbloodpressuremeasurementwithawearablewatchtypemonitorduringimpendingsyncopalepisodes