Cargando…
Retrospective Study for the Clinical Evaluation of a Real-Time PCR Assay with Lyophilized and Ready-to-Use Reagents for Streptococcus agalactiae Detection in Prenatal Screening Specimens
Streptococcus agalactiae is a leading cause of sepsis and meningitis in newborns and young infants. Screening programs and intrapartum antibiotic prophylaxis have reduced early neonatal onset of disease. The aim of this study was to evaluate a molecular assay with lyophilized and ready-to-use reagen...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9497952/ https://www.ncbi.nlm.nih.gov/pubmed/36140590 http://dx.doi.org/10.3390/diagnostics12092189 |
_version_ | 1784794635383603200 |
---|---|
author | Peris, María Paz Martín-Saco, Gloria Alonso-Ezcurra, Henar Escolar-Miñana, Cristina Rezusta, Antonio Acero, Raquel Milagro-Beamonte, Ana |
author_facet | Peris, María Paz Martín-Saco, Gloria Alonso-Ezcurra, Henar Escolar-Miñana, Cristina Rezusta, Antonio Acero, Raquel Milagro-Beamonte, Ana |
author_sort | Peris, María Paz |
collection | PubMed |
description | Streptococcus agalactiae is a leading cause of sepsis and meningitis in newborns and young infants. Screening programs and intrapartum antibiotic prophylaxis have reduced early neonatal onset of disease. The aim of this study was to evaluate a molecular assay with lyophilized and ready-to-use reagents: VIASURE(®) Streptococcus B Real Time PCR detection kit (CerTest Biotec) (Viasure qPCR assay) compared to both the GBS culture and a molecular assay with separated and frozen reagents: Strep B Real-TM Quant (Sacace Biotecnologies(®)) (Sacace qPCR assay). A total of 413 vaginal–rectal swabs from women between the 35th and 37th weeks of pregnancy were processed. GBS culture was firstly achieved through Granada medium and Columbia CNA agar at 35 °C in aerobic conditions. Then, nucleic acid extraction was performed for subsequent molecular analysis using both commercial assays. Discordant results were resolved via bidirectional Sanger sequencing. Viasure qPCR assay clinical sensitivity was 0.97 (0.92–0.99) and specificity 1 (0.98–1). This retrospective study demonstrated the good clinical parameters and the strong overall agreement (99.3%) between the Viasure qPCR assay and both reference assays. Finally, the added value observed of the assay under study was the stabilized and ready-to-use format, reducing the number of time-consuming steps, permitting the storage at room temperature, facilitating transport, being environmentally respectful, and reducing additional costs. |
format | Online Article Text |
id | pubmed-9497952 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-94979522022-09-23 Retrospective Study for the Clinical Evaluation of a Real-Time PCR Assay with Lyophilized and Ready-to-Use Reagents for Streptococcus agalactiae Detection in Prenatal Screening Specimens Peris, María Paz Martín-Saco, Gloria Alonso-Ezcurra, Henar Escolar-Miñana, Cristina Rezusta, Antonio Acero, Raquel Milagro-Beamonte, Ana Diagnostics (Basel) Article Streptococcus agalactiae is a leading cause of sepsis and meningitis in newborns and young infants. Screening programs and intrapartum antibiotic prophylaxis have reduced early neonatal onset of disease. The aim of this study was to evaluate a molecular assay with lyophilized and ready-to-use reagents: VIASURE(®) Streptococcus B Real Time PCR detection kit (CerTest Biotec) (Viasure qPCR assay) compared to both the GBS culture and a molecular assay with separated and frozen reagents: Strep B Real-TM Quant (Sacace Biotecnologies(®)) (Sacace qPCR assay). A total of 413 vaginal–rectal swabs from women between the 35th and 37th weeks of pregnancy were processed. GBS culture was firstly achieved through Granada medium and Columbia CNA agar at 35 °C in aerobic conditions. Then, nucleic acid extraction was performed for subsequent molecular analysis using both commercial assays. Discordant results were resolved via bidirectional Sanger sequencing. Viasure qPCR assay clinical sensitivity was 0.97 (0.92–0.99) and specificity 1 (0.98–1). This retrospective study demonstrated the good clinical parameters and the strong overall agreement (99.3%) between the Viasure qPCR assay and both reference assays. Finally, the added value observed of the assay under study was the stabilized and ready-to-use format, reducing the number of time-consuming steps, permitting the storage at room temperature, facilitating transport, being environmentally respectful, and reducing additional costs. MDPI 2022-09-09 /pmc/articles/PMC9497952/ /pubmed/36140590 http://dx.doi.org/10.3390/diagnostics12092189 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Peris, María Paz Martín-Saco, Gloria Alonso-Ezcurra, Henar Escolar-Miñana, Cristina Rezusta, Antonio Acero, Raquel Milagro-Beamonte, Ana Retrospective Study for the Clinical Evaluation of a Real-Time PCR Assay with Lyophilized and Ready-to-Use Reagents for Streptococcus agalactiae Detection in Prenatal Screening Specimens |
title | Retrospective Study for the Clinical Evaluation of a Real-Time PCR Assay with Lyophilized and Ready-to-Use Reagents for Streptococcus agalactiae Detection in Prenatal Screening Specimens |
title_full | Retrospective Study for the Clinical Evaluation of a Real-Time PCR Assay with Lyophilized and Ready-to-Use Reagents for Streptococcus agalactiae Detection in Prenatal Screening Specimens |
title_fullStr | Retrospective Study for the Clinical Evaluation of a Real-Time PCR Assay with Lyophilized and Ready-to-Use Reagents for Streptococcus agalactiae Detection in Prenatal Screening Specimens |
title_full_unstemmed | Retrospective Study for the Clinical Evaluation of a Real-Time PCR Assay with Lyophilized and Ready-to-Use Reagents for Streptococcus agalactiae Detection in Prenatal Screening Specimens |
title_short | Retrospective Study for the Clinical Evaluation of a Real-Time PCR Assay with Lyophilized and Ready-to-Use Reagents for Streptococcus agalactiae Detection in Prenatal Screening Specimens |
title_sort | retrospective study for the clinical evaluation of a real-time pcr assay with lyophilized and ready-to-use reagents for streptococcus agalactiae detection in prenatal screening specimens |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9497952/ https://www.ncbi.nlm.nih.gov/pubmed/36140590 http://dx.doi.org/10.3390/diagnostics12092189 |
work_keys_str_mv | AT perismariapaz retrospectivestudyfortheclinicalevaluationofarealtimepcrassaywithlyophilizedandreadytousereagentsforstreptococcusagalactiaedetectioninprenatalscreeningspecimens AT martinsacogloria retrospectivestudyfortheclinicalevaluationofarealtimepcrassaywithlyophilizedandreadytousereagentsforstreptococcusagalactiaedetectioninprenatalscreeningspecimens AT alonsoezcurrahenar retrospectivestudyfortheclinicalevaluationofarealtimepcrassaywithlyophilizedandreadytousereagentsforstreptococcusagalactiaedetectioninprenatalscreeningspecimens AT escolarminanacristina retrospectivestudyfortheclinicalevaluationofarealtimepcrassaywithlyophilizedandreadytousereagentsforstreptococcusagalactiaedetectioninprenatalscreeningspecimens AT rezustaantonio retrospectivestudyfortheclinicalevaluationofarealtimepcrassaywithlyophilizedandreadytousereagentsforstreptococcusagalactiaedetectioninprenatalscreeningspecimens AT aceroraquel retrospectivestudyfortheclinicalevaluationofarealtimepcrassaywithlyophilizedandreadytousereagentsforstreptococcusagalactiaedetectioninprenatalscreeningspecimens AT milagrobeamonteana retrospectivestudyfortheclinicalevaluationofarealtimepcrassaywithlyophilizedandreadytousereagentsforstreptococcusagalactiaedetectioninprenatalscreeningspecimens |