Cargando…

Association of Intraocular Pressure and Optical Coherence Tomography Angiography Parameters in Early Glaucoma Treatment

This prospective study aimed to explore the effect of medical intraocular pressure (IOP) reduction on structural and capillary vessel density (VD) change by optical coherence tomography (OCT) angiography in early glaucoma. Patients with newly diagnosed glaucoma and a follow-up of ≥6 months were enro...

Descripción completa

Detalles Bibliográficos
Autores principales: Chuang, Lan-Hsin, Li, Ju-Hsien, Huang, Pei-Wei, Chen, Henry S. L., Liu, Chun-Fu, Yang, Ju-Wen, Lai, Chi-Chun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9498188/
https://www.ncbi.nlm.nih.gov/pubmed/36140574
http://dx.doi.org/10.3390/diagnostics12092174
_version_ 1784794695404093440
author Chuang, Lan-Hsin
Li, Ju-Hsien
Huang, Pei-Wei
Chen, Henry S. L.
Liu, Chun-Fu
Yang, Ju-Wen
Lai, Chi-Chun
author_facet Chuang, Lan-Hsin
Li, Ju-Hsien
Huang, Pei-Wei
Chen, Henry S. L.
Liu, Chun-Fu
Yang, Ju-Wen
Lai, Chi-Chun
author_sort Chuang, Lan-Hsin
collection PubMed
description This prospective study aimed to explore the effect of medical intraocular pressure (IOP) reduction on structural and capillary vessel density (VD) change by optical coherence tomography (OCT) angiography in early glaucoma. Patients with newly diagnosed glaucoma and a follow-up of ≥6 months were enrolled. An ocular examination that included slit-lamp bio-microscopy, pneumatic tonometry, gonioscopy, standard automated perimetry, and OCT angiography was performed. Quantitative OCT angiography parameters were assessed using a linear mixed model that was adjusted for inter-eye correlation. The correlations between IOP changes and OCT angiography parameter changes were analyzed using Spearman’s correlation test. In total, 52 eyes of 36 participants, including 33 glaucoma eyes of 17 participants and 19 healthy eyes of 19 participants served as the case and control groups, respectively. The IOP of the case group decreased from a baseline mean of 20.4 ± 0.8 mmHg to 15.7 ± 0.5 mmHg at 3 months (p < 0.001) and to 16.1 ± 0.5 mmHg at 6 months (p < 0.001). For the subgroup with an IOP reduction of >20%, the deep macula VD was negatively correlated with baseline IOP and significantly decreased at 3 months follow-up. Additionally, change in retinal nerve fiber layer (RNFL) was positively correlated with a change in IOP at 6 months. In conclusion, the deep-layer macula VD was correlated with baseline IOP and influenced by the reduction in IOP in the short term. The changes in VD revealed the vulnerability of the deep vascular complex. The OCTA parameters provide in vivo monitoring information during medical treatment for early glaucoma.
format Online
Article
Text
id pubmed-9498188
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-94981882022-09-23 Association of Intraocular Pressure and Optical Coherence Tomography Angiography Parameters in Early Glaucoma Treatment Chuang, Lan-Hsin Li, Ju-Hsien Huang, Pei-Wei Chen, Henry S. L. Liu, Chun-Fu Yang, Ju-Wen Lai, Chi-Chun Diagnostics (Basel) Article This prospective study aimed to explore the effect of medical intraocular pressure (IOP) reduction on structural and capillary vessel density (VD) change by optical coherence tomography (OCT) angiography in early glaucoma. Patients with newly diagnosed glaucoma and a follow-up of ≥6 months were enrolled. An ocular examination that included slit-lamp bio-microscopy, pneumatic tonometry, gonioscopy, standard automated perimetry, and OCT angiography was performed. Quantitative OCT angiography parameters were assessed using a linear mixed model that was adjusted for inter-eye correlation. The correlations between IOP changes and OCT angiography parameter changes were analyzed using Spearman’s correlation test. In total, 52 eyes of 36 participants, including 33 glaucoma eyes of 17 participants and 19 healthy eyes of 19 participants served as the case and control groups, respectively. The IOP of the case group decreased from a baseline mean of 20.4 ± 0.8 mmHg to 15.7 ± 0.5 mmHg at 3 months (p < 0.001) and to 16.1 ± 0.5 mmHg at 6 months (p < 0.001). For the subgroup with an IOP reduction of >20%, the deep macula VD was negatively correlated with baseline IOP and significantly decreased at 3 months follow-up. Additionally, change in retinal nerve fiber layer (RNFL) was positively correlated with a change in IOP at 6 months. In conclusion, the deep-layer macula VD was correlated with baseline IOP and influenced by the reduction in IOP in the short term. The changes in VD revealed the vulnerability of the deep vascular complex. The OCTA parameters provide in vivo monitoring information during medical treatment for early glaucoma. MDPI 2022-09-08 /pmc/articles/PMC9498188/ /pubmed/36140574 http://dx.doi.org/10.3390/diagnostics12092174 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Chuang, Lan-Hsin
Li, Ju-Hsien
Huang, Pei-Wei
Chen, Henry S. L.
Liu, Chun-Fu
Yang, Ju-Wen
Lai, Chi-Chun
Association of Intraocular Pressure and Optical Coherence Tomography Angiography Parameters in Early Glaucoma Treatment
title Association of Intraocular Pressure and Optical Coherence Tomography Angiography Parameters in Early Glaucoma Treatment
title_full Association of Intraocular Pressure and Optical Coherence Tomography Angiography Parameters in Early Glaucoma Treatment
title_fullStr Association of Intraocular Pressure and Optical Coherence Tomography Angiography Parameters in Early Glaucoma Treatment
title_full_unstemmed Association of Intraocular Pressure and Optical Coherence Tomography Angiography Parameters in Early Glaucoma Treatment
title_short Association of Intraocular Pressure and Optical Coherence Tomography Angiography Parameters in Early Glaucoma Treatment
title_sort association of intraocular pressure and optical coherence tomography angiography parameters in early glaucoma treatment
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9498188/
https://www.ncbi.nlm.nih.gov/pubmed/36140574
http://dx.doi.org/10.3390/diagnostics12092174
work_keys_str_mv AT chuanglanhsin associationofintraocularpressureandopticalcoherencetomographyangiographyparametersinearlyglaucomatreatment
AT lijuhsien associationofintraocularpressureandopticalcoherencetomographyangiographyparametersinearlyglaucomatreatment
AT huangpeiwei associationofintraocularpressureandopticalcoherencetomographyangiographyparametersinearlyglaucomatreatment
AT chenhenrysl associationofintraocularpressureandopticalcoherencetomographyangiographyparametersinearlyglaucomatreatment
AT liuchunfu associationofintraocularpressureandopticalcoherencetomographyangiographyparametersinearlyglaucomatreatment
AT yangjuwen associationofintraocularpressureandopticalcoherencetomographyangiographyparametersinearlyglaucomatreatment
AT laichichun associationofintraocularpressureandopticalcoherencetomographyangiographyparametersinearlyglaucomatreatment