Cargando…

An Observational Study Using Ultrasound to Assess Allowable Needle Insertion Range of Acupoint CV12

Background: Abdominal organ injuries are a rarely reported complication when deep acupuncture needling is applied to the abdomen. In order to ascertain the allowable needle insertion range (ANIR) of the abdomen region, we selected acupoint CV12, which is commonly used for treating gastric disease, a...

Descripción completa

Detalles Bibliográficos
Autores principales: Chu, Hongmin, Kim, Jaehyo, Park, Seongjun, Kim, Jaehyun, Lee, Jung-Han, Ha, Won-Bae, Jung, Hyun-Jong, Yang, Seung-bum, Kim, Cheol-hyun, Park, Jun Yong, Kang, Kyung-ho, Lee, Sangkwan, Lee, Sanghun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9498562/
https://www.ncbi.nlm.nih.gov/pubmed/36141319
http://dx.doi.org/10.3390/healthcare10091707
_version_ 1784794791170539520
author Chu, Hongmin
Kim, Jaehyo
Park, Seongjun
Kim, Jaehyun
Lee, Jung-Han
Ha, Won-Bae
Jung, Hyun-Jong
Yang, Seung-bum
Kim, Cheol-hyun
Park, Jun Yong
Kang, Kyung-ho
Lee, Sangkwan
Lee, Sanghun
author_facet Chu, Hongmin
Kim, Jaehyo
Park, Seongjun
Kim, Jaehyun
Lee, Jung-Han
Ha, Won-Bae
Jung, Hyun-Jong
Yang, Seung-bum
Kim, Cheol-hyun
Park, Jun Yong
Kang, Kyung-ho
Lee, Sangkwan
Lee, Sanghun
author_sort Chu, Hongmin
collection PubMed
description Background: Abdominal organ injuries are a rarely reported complication when deep acupuncture needling is applied to the abdomen. In order to ascertain the allowable needle insertion range (ANIR) of the abdomen region, we selected acupoint CV12, which is commonly used for treating gastric disease, and ANIR was measured with an ultrasound device. Method: Eighty-five healthy volunteers were recruited, of which 83 cases of ultrasound images were obtained. To investigate the prediction factor of ANIR, we also measured several anthropometric factors. Results: The average ANIR was 25.3 ± 10.2; generally, the ANIRs of females were thicker than those of males; and the liver was observed in 62.7% subjects’ ultrasound images. The non-observed group showed thicker ANIR and higher BMI than the liver-observed group. Conclusion: There are reliable variables that make it possible to predict the ANIR. It is advised to refer to anthropometric factors in needling acupoint CV12 to avoid complications with the acupuncture treatment. However, individual differences are not negligible when applying deep needling. Thus, if the risk is not judged before or during the procedure, practitioners could consider the patient’s ANIR on CV12 when applying acupuncture by examining the individual anatomical structures using ultrasound and considering internal organ positions to prevent adverse events due to acupuncture.
format Online
Article
Text
id pubmed-9498562
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-94985622022-09-23 An Observational Study Using Ultrasound to Assess Allowable Needle Insertion Range of Acupoint CV12 Chu, Hongmin Kim, Jaehyo Park, Seongjun Kim, Jaehyun Lee, Jung-Han Ha, Won-Bae Jung, Hyun-Jong Yang, Seung-bum Kim, Cheol-hyun Park, Jun Yong Kang, Kyung-ho Lee, Sangkwan Lee, Sanghun Healthcare (Basel) Article Background: Abdominal organ injuries are a rarely reported complication when deep acupuncture needling is applied to the abdomen. In order to ascertain the allowable needle insertion range (ANIR) of the abdomen region, we selected acupoint CV12, which is commonly used for treating gastric disease, and ANIR was measured with an ultrasound device. Method: Eighty-five healthy volunteers were recruited, of which 83 cases of ultrasound images were obtained. To investigate the prediction factor of ANIR, we also measured several anthropometric factors. Results: The average ANIR was 25.3 ± 10.2; generally, the ANIRs of females were thicker than those of males; and the liver was observed in 62.7% subjects’ ultrasound images. The non-observed group showed thicker ANIR and higher BMI than the liver-observed group. Conclusion: There are reliable variables that make it possible to predict the ANIR. It is advised to refer to anthropometric factors in needling acupoint CV12 to avoid complications with the acupuncture treatment. However, individual differences are not negligible when applying deep needling. Thus, if the risk is not judged before or during the procedure, practitioners could consider the patient’s ANIR on CV12 when applying acupuncture by examining the individual anatomical structures using ultrasound and considering internal organ positions to prevent adverse events due to acupuncture. MDPI 2022-09-06 /pmc/articles/PMC9498562/ /pubmed/36141319 http://dx.doi.org/10.3390/healthcare10091707 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Chu, Hongmin
Kim, Jaehyo
Park, Seongjun
Kim, Jaehyun
Lee, Jung-Han
Ha, Won-Bae
Jung, Hyun-Jong
Yang, Seung-bum
Kim, Cheol-hyun
Park, Jun Yong
Kang, Kyung-ho
Lee, Sangkwan
Lee, Sanghun
An Observational Study Using Ultrasound to Assess Allowable Needle Insertion Range of Acupoint CV12
title An Observational Study Using Ultrasound to Assess Allowable Needle Insertion Range of Acupoint CV12
title_full An Observational Study Using Ultrasound to Assess Allowable Needle Insertion Range of Acupoint CV12
title_fullStr An Observational Study Using Ultrasound to Assess Allowable Needle Insertion Range of Acupoint CV12
title_full_unstemmed An Observational Study Using Ultrasound to Assess Allowable Needle Insertion Range of Acupoint CV12
title_short An Observational Study Using Ultrasound to Assess Allowable Needle Insertion Range of Acupoint CV12
title_sort observational study using ultrasound to assess allowable needle insertion range of acupoint cv12
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9498562/
https://www.ncbi.nlm.nih.gov/pubmed/36141319
http://dx.doi.org/10.3390/healthcare10091707
work_keys_str_mv AT chuhongmin anobservationalstudyusingultrasoundtoassessallowableneedleinsertionrangeofacupointcv12
AT kimjaehyo anobservationalstudyusingultrasoundtoassessallowableneedleinsertionrangeofacupointcv12
AT parkseongjun anobservationalstudyusingultrasoundtoassessallowableneedleinsertionrangeofacupointcv12
AT kimjaehyun anobservationalstudyusingultrasoundtoassessallowableneedleinsertionrangeofacupointcv12
AT leejunghan anobservationalstudyusingultrasoundtoassessallowableneedleinsertionrangeofacupointcv12
AT hawonbae anobservationalstudyusingultrasoundtoassessallowableneedleinsertionrangeofacupointcv12
AT junghyunjong anobservationalstudyusingultrasoundtoassessallowableneedleinsertionrangeofacupointcv12
AT yangseungbum anobservationalstudyusingultrasoundtoassessallowableneedleinsertionrangeofacupointcv12
AT kimcheolhyun anobservationalstudyusingultrasoundtoassessallowableneedleinsertionrangeofacupointcv12
AT parkjunyong anobservationalstudyusingultrasoundtoassessallowableneedleinsertionrangeofacupointcv12
AT kangkyungho anobservationalstudyusingultrasoundtoassessallowableneedleinsertionrangeofacupointcv12
AT leesangkwan anobservationalstudyusingultrasoundtoassessallowableneedleinsertionrangeofacupointcv12
AT leesanghun anobservationalstudyusingultrasoundtoassessallowableneedleinsertionrangeofacupointcv12
AT chuhongmin observationalstudyusingultrasoundtoassessallowableneedleinsertionrangeofacupointcv12
AT kimjaehyo observationalstudyusingultrasoundtoassessallowableneedleinsertionrangeofacupointcv12
AT parkseongjun observationalstudyusingultrasoundtoassessallowableneedleinsertionrangeofacupointcv12
AT kimjaehyun observationalstudyusingultrasoundtoassessallowableneedleinsertionrangeofacupointcv12
AT leejunghan observationalstudyusingultrasoundtoassessallowableneedleinsertionrangeofacupointcv12
AT hawonbae observationalstudyusingultrasoundtoassessallowableneedleinsertionrangeofacupointcv12
AT junghyunjong observationalstudyusingultrasoundtoassessallowableneedleinsertionrangeofacupointcv12
AT yangseungbum observationalstudyusingultrasoundtoassessallowableneedleinsertionrangeofacupointcv12
AT kimcheolhyun observationalstudyusingultrasoundtoassessallowableneedleinsertionrangeofacupointcv12
AT parkjunyong observationalstudyusingultrasoundtoassessallowableneedleinsertionrangeofacupointcv12
AT kangkyungho observationalstudyusingultrasoundtoassessallowableneedleinsertionrangeofacupointcv12
AT leesangkwan observationalstudyusingultrasoundtoassessallowableneedleinsertionrangeofacupointcv12
AT leesanghun observationalstudyusingultrasoundtoassessallowableneedleinsertionrangeofacupointcv12