Cargando…
A Single Fast Test for Semicircular Canal Dehiscence—oVEMP n10 to 4000 Hz—Depends on Stimulus Rise Time
As previously reported, a single test measuring oVEMP n10 to 4000 Hz stimuli (bone-conducted vibration (BCV) or air-conducted sound (ACS)) provides a definitive diagnosis of semicircular canal dehiscence (SCD) in 22 CT-verified patients, with a sensitivity of 1.0 and specificity of 1.0. This single...
Autores principales: | Curthoys, Ian S., Burgess, Ann M., Manzari, Leonardo, Pastras, Christopher J. |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9498918/ https://www.ncbi.nlm.nih.gov/pubmed/36136853 http://dx.doi.org/10.3390/audiolres12050046 |
Ejemplares similares
-
Investigating Performance of cVEMP and oVEMP in the Identification of Superior Canal Dehiscence in Relation to Dehiscence Location and Size
por: Maheu, Maxime, et al.
Publicado: (2021) -
A Simple Specific Functional Test for SCD: VEMPs to High Frequency (4,000Hz) Stimuli—Their Origin and Explanation
por: Curthoys, Ian S., et al.
Publicado: (2020) -
Ocular vestibular-evoked myogenic potential (oVEMP) to test utricular function: neural and oculomotor evidence
por: CURTHOYS, I.S., et al.
Publicado: (2012) -
Vestibular Evoked Myogenic Potential (VEMP) Testing for Diagnosis of Superior Semicircular Canal Dehiscence
por: Noij, Kimberley S., et al.
Publicado: (2020) -
Bone-Conducted oVEMP Latency Delays Assist in the Differential Diagnosis of Large Air-Conducted oVEMP Amplitudes
por: Taylor, Rachael L., et al.
Publicado: (2020)