Cargando…

A Rare Case of Open 3A VTB2W Periprosthetic Fracture around a Total Hip Arthroplasty

INTRODUCTION: The incidence of periprosthetic fracture (PPF) around a total hip arthroplasty (THA) continues to increase with the rise of number of THA performed. We present a rare case of a 73-year-old man who sustained an open periprosthetic femur fracture around a THA. CASE REPORT: This gentleman...

Descripción completa

Detalles Bibliográficos
Autores principales: Selvaratnam, Veenesh, Kassam, Al-Amin, Hubble, Matthew J W
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Indian Orthopaedic Research Group 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9499062/
https://www.ncbi.nlm.nih.gov/pubmed/36199927
http://dx.doi.org/10.13107/jocr.2022.v12.i03.2722
_version_ 1784794910934695936
author Selvaratnam, Veenesh
Kassam, Al-Amin
Hubble, Matthew J W
author_facet Selvaratnam, Veenesh
Kassam, Al-Amin
Hubble, Matthew J W
author_sort Selvaratnam, Veenesh
collection PubMed
description INTRODUCTION: The incidence of periprosthetic fracture (PPF) around a total hip arthroplasty (THA) continues to increase with the rise of number of THA performed. We present a rare case of a 73-year-old man who sustained an open periprosthetic femur fracture around a THA. CASE REPORT: This gentleman sustained an open PPF around a fully cemented THA after he lost control and fell off his bicycle. After thorough surgical debridement, internal fixation with double plating was performed and the fracture went on to unite with an excellent patient reported outcome score. To the best of our knowledge, this is the only reported open 3A VTB2W PPF THA in the literature. CONCLUSION: Open PPF around a THA is a rare and uncommon occurrence. Principles of open fracture management should be continued and we recommend urgent surgery to reduce the risk of post-operative infection. Open VTB2W PPF should be fixed with double plating if the bone cement interface is intact and the fracture can be anatomically reduced. Double plating gives additional rotational stability and allows early weight bearing post-operatively.
format Online
Article
Text
id pubmed-9499062
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Indian Orthopaedic Research Group
record_format MEDLINE/PubMed
spelling pubmed-94990622022-10-04 A Rare Case of Open 3A VTB2W Periprosthetic Fracture around a Total Hip Arthroplasty Selvaratnam, Veenesh Kassam, Al-Amin Hubble, Matthew J W J Orthop Case Rep Case Report INTRODUCTION: The incidence of periprosthetic fracture (PPF) around a total hip arthroplasty (THA) continues to increase with the rise of number of THA performed. We present a rare case of a 73-year-old man who sustained an open periprosthetic femur fracture around a THA. CASE REPORT: This gentleman sustained an open PPF around a fully cemented THA after he lost control and fell off his bicycle. After thorough surgical debridement, internal fixation with double plating was performed and the fracture went on to unite with an excellent patient reported outcome score. To the best of our knowledge, this is the only reported open 3A VTB2W PPF THA in the literature. CONCLUSION: Open PPF around a THA is a rare and uncommon occurrence. Principles of open fracture management should be continued and we recommend urgent surgery to reduce the risk of post-operative infection. Open VTB2W PPF should be fixed with double plating if the bone cement interface is intact and the fracture can be anatomically reduced. Double plating gives additional rotational stability and allows early weight bearing post-operatively. Indian Orthopaedic Research Group 2022-03 2022-03 /pmc/articles/PMC9499062/ /pubmed/36199927 http://dx.doi.org/10.13107/jocr.2022.v12.i03.2722 Text en Copyright: © Indian Orthopaedic Research Group https://creativecommons.org/licenses/by-nc-sa/3.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Selvaratnam, Veenesh
Kassam, Al-Amin
Hubble, Matthew J W
A Rare Case of Open 3A VTB2W Periprosthetic Fracture around a Total Hip Arthroplasty
title A Rare Case of Open 3A VTB2W Periprosthetic Fracture around a Total Hip Arthroplasty
title_full A Rare Case of Open 3A VTB2W Periprosthetic Fracture around a Total Hip Arthroplasty
title_fullStr A Rare Case of Open 3A VTB2W Periprosthetic Fracture around a Total Hip Arthroplasty
title_full_unstemmed A Rare Case of Open 3A VTB2W Periprosthetic Fracture around a Total Hip Arthroplasty
title_short A Rare Case of Open 3A VTB2W Periprosthetic Fracture around a Total Hip Arthroplasty
title_sort rare case of open 3a vtb2w periprosthetic fracture around a total hip arthroplasty
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9499062/
https://www.ncbi.nlm.nih.gov/pubmed/36199927
http://dx.doi.org/10.13107/jocr.2022.v12.i03.2722
work_keys_str_mv AT selvaratnamveenesh ararecaseofopen3avtb2wperiprostheticfracturearoundatotalhiparthroplasty
AT kassamalamin ararecaseofopen3avtb2wperiprostheticfracturearoundatotalhiparthroplasty
AT hubblematthewjw ararecaseofopen3avtb2wperiprostheticfracturearoundatotalhiparthroplasty
AT selvaratnamveenesh rarecaseofopen3avtb2wperiprostheticfracturearoundatotalhiparthroplasty
AT kassamalamin rarecaseofopen3avtb2wperiprostheticfracturearoundatotalhiparthroplasty
AT hubblematthewjw rarecaseofopen3avtb2wperiprostheticfracturearoundatotalhiparthroplasty