Cargando…
A Rare Case of Open 3A VTB2W Periprosthetic Fracture around a Total Hip Arthroplasty
INTRODUCTION: The incidence of periprosthetic fracture (PPF) around a total hip arthroplasty (THA) continues to increase with the rise of number of THA performed. We present a rare case of a 73-year-old man who sustained an open periprosthetic femur fracture around a THA. CASE REPORT: This gentleman...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Indian Orthopaedic Research Group
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9499062/ https://www.ncbi.nlm.nih.gov/pubmed/36199927 http://dx.doi.org/10.13107/jocr.2022.v12.i03.2722 |
_version_ | 1784794910934695936 |
---|---|
author | Selvaratnam, Veenesh Kassam, Al-Amin Hubble, Matthew J W |
author_facet | Selvaratnam, Veenesh Kassam, Al-Amin Hubble, Matthew J W |
author_sort | Selvaratnam, Veenesh |
collection | PubMed |
description | INTRODUCTION: The incidence of periprosthetic fracture (PPF) around a total hip arthroplasty (THA) continues to increase with the rise of number of THA performed. We present a rare case of a 73-year-old man who sustained an open periprosthetic femur fracture around a THA. CASE REPORT: This gentleman sustained an open PPF around a fully cemented THA after he lost control and fell off his bicycle. After thorough surgical debridement, internal fixation with double plating was performed and the fracture went on to unite with an excellent patient reported outcome score. To the best of our knowledge, this is the only reported open 3A VTB2W PPF THA in the literature. CONCLUSION: Open PPF around a THA is a rare and uncommon occurrence. Principles of open fracture management should be continued and we recommend urgent surgery to reduce the risk of post-operative infection. Open VTB2W PPF should be fixed with double plating if the bone cement interface is intact and the fracture can be anatomically reduced. Double plating gives additional rotational stability and allows early weight bearing post-operatively. |
format | Online Article Text |
id | pubmed-9499062 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Indian Orthopaedic Research Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-94990622022-10-04 A Rare Case of Open 3A VTB2W Periprosthetic Fracture around a Total Hip Arthroplasty Selvaratnam, Veenesh Kassam, Al-Amin Hubble, Matthew J W J Orthop Case Rep Case Report INTRODUCTION: The incidence of periprosthetic fracture (PPF) around a total hip arthroplasty (THA) continues to increase with the rise of number of THA performed. We present a rare case of a 73-year-old man who sustained an open periprosthetic femur fracture around a THA. CASE REPORT: This gentleman sustained an open PPF around a fully cemented THA after he lost control and fell off his bicycle. After thorough surgical debridement, internal fixation with double plating was performed and the fracture went on to unite with an excellent patient reported outcome score. To the best of our knowledge, this is the only reported open 3A VTB2W PPF THA in the literature. CONCLUSION: Open PPF around a THA is a rare and uncommon occurrence. Principles of open fracture management should be continued and we recommend urgent surgery to reduce the risk of post-operative infection. Open VTB2W PPF should be fixed with double plating if the bone cement interface is intact and the fracture can be anatomically reduced. Double plating gives additional rotational stability and allows early weight bearing post-operatively. Indian Orthopaedic Research Group 2022-03 2022-03 /pmc/articles/PMC9499062/ /pubmed/36199927 http://dx.doi.org/10.13107/jocr.2022.v12.i03.2722 Text en Copyright: © Indian Orthopaedic Research Group https://creativecommons.org/licenses/by-nc-sa/3.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Selvaratnam, Veenesh Kassam, Al-Amin Hubble, Matthew J W A Rare Case of Open 3A VTB2W Periprosthetic Fracture around a Total Hip Arthroplasty |
title | A Rare Case of Open 3A VTB2W Periprosthetic Fracture around a Total Hip Arthroplasty |
title_full | A Rare Case of Open 3A VTB2W Periprosthetic Fracture around a Total Hip Arthroplasty |
title_fullStr | A Rare Case of Open 3A VTB2W Periprosthetic Fracture around a Total Hip Arthroplasty |
title_full_unstemmed | A Rare Case of Open 3A VTB2W Periprosthetic Fracture around a Total Hip Arthroplasty |
title_short | A Rare Case of Open 3A VTB2W Periprosthetic Fracture around a Total Hip Arthroplasty |
title_sort | rare case of open 3a vtb2w periprosthetic fracture around a total hip arthroplasty |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9499062/ https://www.ncbi.nlm.nih.gov/pubmed/36199927 http://dx.doi.org/10.13107/jocr.2022.v12.i03.2722 |
work_keys_str_mv | AT selvaratnamveenesh ararecaseofopen3avtb2wperiprostheticfracturearoundatotalhiparthroplasty AT kassamalamin ararecaseofopen3avtb2wperiprostheticfracturearoundatotalhiparthroplasty AT hubblematthewjw ararecaseofopen3avtb2wperiprostheticfracturearoundatotalhiparthroplasty AT selvaratnamveenesh rarecaseofopen3avtb2wperiprostheticfracturearoundatotalhiparthroplasty AT kassamalamin rarecaseofopen3avtb2wperiprostheticfracturearoundatotalhiparthroplasty AT hubblematthewjw rarecaseofopen3avtb2wperiprostheticfracturearoundatotalhiparthroplasty |