Comparison of INTEGRA and the Manual Method to Determine the Axis for Intraocular Lens Implantation—A Case Series of 60 Eyes
(1) Background: To compare the results of a new intraoperative contactless device (INTEGRA Optomed, Poland) with the result of a manual method for determining the axis for toric intraocular lens implantation. (2) Material and Methods: This retrospective observational study included 60 eyes of 40 pat...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9499115/ https://www.ncbi.nlm.nih.gov/pubmed/36141385 http://dx.doi.org/10.3390/healthcare10091773 |
_version_ | 1784794921095397376 |
---|---|
author | Jaworski, Marcin Wyględowska-Promieńska, Dorota Jaworski, Piotr Kowalski, Michał Jaskot, Krzysztof Bieda, Robert |
author_facet | Jaworski, Marcin Wyględowska-Promieńska, Dorota Jaworski, Piotr Kowalski, Michał Jaskot, Krzysztof Bieda, Robert |
author_sort | Jaworski, Marcin |
collection | PubMed |
description | (1) Background: To compare the results of a new intraoperative contactless device (INTEGRA Optomed, Poland) with the result of a manual method for determining the axis for toric intraocular lens implantation. (2) Material and Methods: This retrospective observational study included 60 eyes of 40 patients (17 men, 23 women) who had toric intraocular lenses implanted. A video recording of each surgery that used the INTEGRA system was made for the analysis. Two researchers then independently assessed the location of the implant axes determined with both digital and manual slit-lamp methods, and compared the results between methods. (3) Results: The implantation axes suggested through the manual and INTEGRA methods were similar. The median axis disparities were 0.0 degrees for both groups. The standard deviation was 0.63 and 0.75 for researcher 1 and 2, respectively. The dominant value was 0.0 in both groups. The INTEGRA axis designation was statistically significantly different from the manual method for researcher 1 (p < 0.05), but it was statistically insignificant for researcher 2 (p = 0.79). (4) Conclusions: The INTEGRA system is a digital ink-free device for image tracking scleral vessels. It was helpful for determining the implantation axis in a precise manner, and the measurements were comparable with those obtained through a manual technique. |
format | Online Article Text |
id | pubmed-9499115 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-94991152022-09-23 Comparison of INTEGRA and the Manual Method to Determine the Axis for Intraocular Lens Implantation—A Case Series of 60 Eyes Jaworski, Marcin Wyględowska-Promieńska, Dorota Jaworski, Piotr Kowalski, Michał Jaskot, Krzysztof Bieda, Robert Healthcare (Basel) Article (1) Background: To compare the results of a new intraoperative contactless device (INTEGRA Optomed, Poland) with the result of a manual method for determining the axis for toric intraocular lens implantation. (2) Material and Methods: This retrospective observational study included 60 eyes of 40 patients (17 men, 23 women) who had toric intraocular lenses implanted. A video recording of each surgery that used the INTEGRA system was made for the analysis. Two researchers then independently assessed the location of the implant axes determined with both digital and manual slit-lamp methods, and compared the results between methods. (3) Results: The implantation axes suggested through the manual and INTEGRA methods were similar. The median axis disparities were 0.0 degrees for both groups. The standard deviation was 0.63 and 0.75 for researcher 1 and 2, respectively. The dominant value was 0.0 in both groups. The INTEGRA axis designation was statistically significantly different from the manual method for researcher 1 (p < 0.05), but it was statistically insignificant for researcher 2 (p = 0.79). (4) Conclusions: The INTEGRA system is a digital ink-free device for image tracking scleral vessels. It was helpful for determining the implantation axis in a precise manner, and the measurements were comparable with those obtained through a manual technique. MDPI 2022-09-14 /pmc/articles/PMC9499115/ /pubmed/36141385 http://dx.doi.org/10.3390/healthcare10091773 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Jaworski, Marcin Wyględowska-Promieńska, Dorota Jaworski, Piotr Kowalski, Michał Jaskot, Krzysztof Bieda, Robert Comparison of INTEGRA and the Manual Method to Determine the Axis for Intraocular Lens Implantation—A Case Series of 60 Eyes |
title | Comparison of INTEGRA and the Manual Method to Determine the Axis for Intraocular Lens Implantation—A Case Series of 60 Eyes |
title_full | Comparison of INTEGRA and the Manual Method to Determine the Axis for Intraocular Lens Implantation—A Case Series of 60 Eyes |
title_fullStr | Comparison of INTEGRA and the Manual Method to Determine the Axis for Intraocular Lens Implantation—A Case Series of 60 Eyes |
title_full_unstemmed | Comparison of INTEGRA and the Manual Method to Determine the Axis for Intraocular Lens Implantation—A Case Series of 60 Eyes |
title_short | Comparison of INTEGRA and the Manual Method to Determine the Axis for Intraocular Lens Implantation—A Case Series of 60 Eyes |
title_sort | comparison of integra and the manual method to determine the axis for intraocular lens implantation—a case series of 60 eyes |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9499115/ https://www.ncbi.nlm.nih.gov/pubmed/36141385 http://dx.doi.org/10.3390/healthcare10091773 |
work_keys_str_mv | AT jaworskimarcin comparisonofintegraandthemanualmethodtodeterminetheaxisforintraocularlensimplantationacaseseriesof60eyes AT wygledowskapromienskadorota comparisonofintegraandthemanualmethodtodeterminetheaxisforintraocularlensimplantationacaseseriesof60eyes AT jaworskipiotr comparisonofintegraandthemanualmethodtodeterminetheaxisforintraocularlensimplantationacaseseriesof60eyes AT kowalskimichał comparisonofintegraandthemanualmethodtodeterminetheaxisforintraocularlensimplantationacaseseriesof60eyes AT jaskotkrzysztof comparisonofintegraandthemanualmethodtodeterminetheaxisforintraocularlensimplantationacaseseriesof60eyes AT biedarobert comparisonofintegraandthemanualmethodtodeterminetheaxisforintraocularlensimplantationacaseseriesof60eyes |