Comparison of INTEGRA and the Manual Method to Determine the Axis for Intraocular Lens Implantation—A Case Series of 60 Eyes

(1) Background: To compare the results of a new intraoperative contactless device (INTEGRA Optomed, Poland) with the result of a manual method for determining the axis for toric intraocular lens implantation. (2) Material and Methods: This retrospective observational study included 60 eyes of 40 pat...

Descripción completa

Detalles Bibliográficos
Autores principales: Jaworski, Marcin, Wyględowska-Promieńska, Dorota, Jaworski, Piotr, Kowalski, Michał, Jaskot, Krzysztof, Bieda, Robert
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9499115/
https://www.ncbi.nlm.nih.gov/pubmed/36141385
http://dx.doi.org/10.3390/healthcare10091773
_version_ 1784794921095397376
author Jaworski, Marcin
Wyględowska-Promieńska, Dorota
Jaworski, Piotr
Kowalski, Michał
Jaskot, Krzysztof
Bieda, Robert
author_facet Jaworski, Marcin
Wyględowska-Promieńska, Dorota
Jaworski, Piotr
Kowalski, Michał
Jaskot, Krzysztof
Bieda, Robert
author_sort Jaworski, Marcin
collection PubMed
description (1) Background: To compare the results of a new intraoperative contactless device (INTEGRA Optomed, Poland) with the result of a manual method for determining the axis for toric intraocular lens implantation. (2) Material and Methods: This retrospective observational study included 60 eyes of 40 patients (17 men, 23 women) who had toric intraocular lenses implanted. A video recording of each surgery that used the INTEGRA system was made for the analysis. Two researchers then independently assessed the location of the implant axes determined with both digital and manual slit-lamp methods, and compared the results between methods. (3) Results: The implantation axes suggested through the manual and INTEGRA methods were similar. The median axis disparities were 0.0 degrees for both groups. The standard deviation was 0.63 and 0.75 for researcher 1 and 2, respectively. The dominant value was 0.0 in both groups. The INTEGRA axis designation was statistically significantly different from the manual method for researcher 1 (p < 0.05), but it was statistically insignificant for researcher 2 (p = 0.79). (4) Conclusions: The INTEGRA system is a digital ink-free device for image tracking scleral vessels. It was helpful for determining the implantation axis in a precise manner, and the measurements were comparable with those obtained through a manual technique.
format Online
Article
Text
id pubmed-9499115
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-94991152022-09-23 Comparison of INTEGRA and the Manual Method to Determine the Axis for Intraocular Lens Implantation—A Case Series of 60 Eyes Jaworski, Marcin Wyględowska-Promieńska, Dorota Jaworski, Piotr Kowalski, Michał Jaskot, Krzysztof Bieda, Robert Healthcare (Basel) Article (1) Background: To compare the results of a new intraoperative contactless device (INTEGRA Optomed, Poland) with the result of a manual method for determining the axis for toric intraocular lens implantation. (2) Material and Methods: This retrospective observational study included 60 eyes of 40 patients (17 men, 23 women) who had toric intraocular lenses implanted. A video recording of each surgery that used the INTEGRA system was made for the analysis. Two researchers then independently assessed the location of the implant axes determined with both digital and manual slit-lamp methods, and compared the results between methods. (3) Results: The implantation axes suggested through the manual and INTEGRA methods were similar. The median axis disparities were 0.0 degrees for both groups. The standard deviation was 0.63 and 0.75 for researcher 1 and 2, respectively. The dominant value was 0.0 in both groups. The INTEGRA axis designation was statistically significantly different from the manual method for researcher 1 (p < 0.05), but it was statistically insignificant for researcher 2 (p = 0.79). (4) Conclusions: The INTEGRA system is a digital ink-free device for image tracking scleral vessels. It was helpful for determining the implantation axis in a precise manner, and the measurements were comparable with those obtained through a manual technique. MDPI 2022-09-14 /pmc/articles/PMC9499115/ /pubmed/36141385 http://dx.doi.org/10.3390/healthcare10091773 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Jaworski, Marcin
Wyględowska-Promieńska, Dorota
Jaworski, Piotr
Kowalski, Michał
Jaskot, Krzysztof
Bieda, Robert
Comparison of INTEGRA and the Manual Method to Determine the Axis for Intraocular Lens Implantation—A Case Series of 60 Eyes
title Comparison of INTEGRA and the Manual Method to Determine the Axis for Intraocular Lens Implantation—A Case Series of 60 Eyes
title_full Comparison of INTEGRA and the Manual Method to Determine the Axis for Intraocular Lens Implantation—A Case Series of 60 Eyes
title_fullStr Comparison of INTEGRA and the Manual Method to Determine the Axis for Intraocular Lens Implantation—A Case Series of 60 Eyes
title_full_unstemmed Comparison of INTEGRA and the Manual Method to Determine the Axis for Intraocular Lens Implantation—A Case Series of 60 Eyes
title_short Comparison of INTEGRA and the Manual Method to Determine the Axis for Intraocular Lens Implantation—A Case Series of 60 Eyes
title_sort comparison of integra and the manual method to determine the axis for intraocular lens implantation—a case series of 60 eyes
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9499115/
https://www.ncbi.nlm.nih.gov/pubmed/36141385
http://dx.doi.org/10.3390/healthcare10091773
work_keys_str_mv AT jaworskimarcin comparisonofintegraandthemanualmethodtodeterminetheaxisforintraocularlensimplantationacaseseriesof60eyes
AT wygledowskapromienskadorota comparisonofintegraandthemanualmethodtodeterminetheaxisforintraocularlensimplantationacaseseriesof60eyes
AT jaworskipiotr comparisonofintegraandthemanualmethodtodeterminetheaxisforintraocularlensimplantationacaseseriesof60eyes
AT kowalskimichał comparisonofintegraandthemanualmethodtodeterminetheaxisforintraocularlensimplantationacaseseriesof60eyes
AT jaskotkrzysztof comparisonofintegraandthemanualmethodtodeterminetheaxisforintraocularlensimplantationacaseseriesof60eyes
AT biedarobert comparisonofintegraandthemanualmethodtodeterminetheaxisforintraocularlensimplantationacaseseriesof60eyes