Cargando…

Comparison of surface- and voxel-based registration on the mandibular ramus for long-term three-dimensional assessment of condylar remodelling following orthognathic surgery

OBJECTIVES: The purpose of the present study was to validate and compare the accuracy and reliability of surface- and voxel-based registration on the mandibular rami for long-term three-dimensional (3D) evaluation of condylar remodelling following Orthognathic Surgery. METHODS: The mandible was 3D r...

Descripción completa

Detalles Bibliográficos
Autores principales: Holte, Michael Boelstoft, Sæderup, Henrik, Pinholt, Else Marie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The British Institute of Radiology. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9499205/
https://www.ncbi.nlm.nih.gov/pubmed/35143288
http://dx.doi.org/10.1259/dmfr.20210499
_version_ 1784794939390951424
author Holte, Michael Boelstoft
Sæderup, Henrik
Pinholt, Else Marie
author_facet Holte, Michael Boelstoft
Sæderup, Henrik
Pinholt, Else Marie
author_sort Holte, Michael Boelstoft
collection PubMed
description OBJECTIVES: The purpose of the present study was to validate and compare the accuracy and reliability of surface- and voxel-based registration on the mandibular rami for long-term three-dimensional (3D) evaluation of condylar remodelling following Orthognathic Surgery. METHODS: The mandible was 3D reconstructed from a pair of superimposed pre- and postoperative (two years) cone-beam computerized tomography scans and divided into the condyle, and 21 ramal regions. The accuracy of surface- and voxel-based registration was measured by the absolute mean surface distance of each region after alignment of the pre- and postoperative rami. To evaluate the reliability, mean absolute differences and intraclass correlation coefficients (ICC) were calculated at a 95% confidence interval on volumetric and surface distance measurements of two observers. Paired t-tests were applied to statistically evaluate whether the accuracy and reliability of surface- and voxel-based registration were significantly different (p < 0.05). RESULTS: A total of twenty subjects (sixteen female; four male; mean age 27.6 years) with class II malocclusion and maxillomandibular retrognathia, who underwent bimaxillary surgery, were included. Surface-based registration was more accurate and reliable than voxel-based registration on the mandibular ramus two years post-surgery (p < 0.05). The interobserver reliability of using surface-based registration was excellent, ICC range [0.82–1.00]. For voxel-based registration, the interobserver reliability ranged from poor to excellent [0.00–0.98]. The measurement error introduced by applying surface-based registration for assessment of condylar remodelling was considered clinical irrelevant (1.83% and 0.18 mm), while the measurement error introduced by voxel-based registration was considered clinical relevant (5.44% and 0.52 mm). CONCLUSIONS: Surface-based registration was proven more accurate and reliable compared to voxel-based registration on the mandibular ramus for long-term 3D assessment of condylar remodelling following Orthognathic Surgery. However, importantly, the performance difference may be caused by an inappropriate reference structure, proposed in the literature, and applied in this study.
format Online
Article
Text
id pubmed-9499205
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The British Institute of Radiology.
record_format MEDLINE/PubMed
spelling pubmed-94992052023-05-01 Comparison of surface- and voxel-based registration on the mandibular ramus for long-term three-dimensional assessment of condylar remodelling following orthognathic surgery Holte, Michael Boelstoft Sæderup, Henrik Pinholt, Else Marie Dentomaxillofac Radiol Research Article OBJECTIVES: The purpose of the present study was to validate and compare the accuracy and reliability of surface- and voxel-based registration on the mandibular rami for long-term three-dimensional (3D) evaluation of condylar remodelling following Orthognathic Surgery. METHODS: The mandible was 3D reconstructed from a pair of superimposed pre- and postoperative (two years) cone-beam computerized tomography scans and divided into the condyle, and 21 ramal regions. The accuracy of surface- and voxel-based registration was measured by the absolute mean surface distance of each region after alignment of the pre- and postoperative rami. To evaluate the reliability, mean absolute differences and intraclass correlation coefficients (ICC) were calculated at a 95% confidence interval on volumetric and surface distance measurements of two observers. Paired t-tests were applied to statistically evaluate whether the accuracy and reliability of surface- and voxel-based registration were significantly different (p < 0.05). RESULTS: A total of twenty subjects (sixteen female; four male; mean age 27.6 years) with class II malocclusion and maxillomandibular retrognathia, who underwent bimaxillary surgery, were included. Surface-based registration was more accurate and reliable than voxel-based registration on the mandibular ramus two years post-surgery (p < 0.05). The interobserver reliability of using surface-based registration was excellent, ICC range [0.82–1.00]. For voxel-based registration, the interobserver reliability ranged from poor to excellent [0.00–0.98]. The measurement error introduced by applying surface-based registration for assessment of condylar remodelling was considered clinical irrelevant (1.83% and 0.18 mm), while the measurement error introduced by voxel-based registration was considered clinical relevant (5.44% and 0.52 mm). CONCLUSIONS: Surface-based registration was proven more accurate and reliable compared to voxel-based registration on the mandibular ramus for long-term 3D assessment of condylar remodelling following Orthognathic Surgery. However, importantly, the performance difference may be caused by an inappropriate reference structure, proposed in the literature, and applied in this study. The British Institute of Radiology. 2022-05-01 2022-02-25 /pmc/articles/PMC9499205/ /pubmed/35143288 http://dx.doi.org/10.1259/dmfr.20210499 Text en © 2022 The Authors. Published by the British Institute of Radiology https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution 4.0 Unported License http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Holte, Michael Boelstoft
Sæderup, Henrik
Pinholt, Else Marie
Comparison of surface- and voxel-based registration on the mandibular ramus for long-term three-dimensional assessment of condylar remodelling following orthognathic surgery
title Comparison of surface- and voxel-based registration on the mandibular ramus for long-term three-dimensional assessment of condylar remodelling following orthognathic surgery
title_full Comparison of surface- and voxel-based registration on the mandibular ramus for long-term three-dimensional assessment of condylar remodelling following orthognathic surgery
title_fullStr Comparison of surface- and voxel-based registration on the mandibular ramus for long-term three-dimensional assessment of condylar remodelling following orthognathic surgery
title_full_unstemmed Comparison of surface- and voxel-based registration on the mandibular ramus for long-term three-dimensional assessment of condylar remodelling following orthognathic surgery
title_short Comparison of surface- and voxel-based registration on the mandibular ramus for long-term three-dimensional assessment of condylar remodelling following orthognathic surgery
title_sort comparison of surface- and voxel-based registration on the mandibular ramus for long-term three-dimensional assessment of condylar remodelling following orthognathic surgery
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9499205/
https://www.ncbi.nlm.nih.gov/pubmed/35143288
http://dx.doi.org/10.1259/dmfr.20210499
work_keys_str_mv AT holtemichaelboelstoft comparisonofsurfaceandvoxelbasedregistrationonthemandibularramusforlongtermthreedimensionalassessmentofcondylarremodellingfollowingorthognathicsurgery
AT sæderuphenrik comparisonofsurfaceandvoxelbasedregistrationonthemandibularramusforlongtermthreedimensionalassessmentofcondylarremodellingfollowingorthognathicsurgery
AT pinholtelsemarie comparisonofsurfaceandvoxelbasedregistrationonthemandibularramusforlongtermthreedimensionalassessmentofcondylarremodellingfollowingorthognathicsurgery