Decreased Platelet Specific Receptor Expression of P-Selectin and GPIIb/IIIa Predict Future Non-Surgical Bleeding in Patients after Left Ventricular Assist Device Implantation

Non-surgical bleeding (NSB) is one of the major clinical complications in patients under continuous-flow left ventricular assist device (LVAD) support. The increased shear stress leads to an altered platelet receptor composition. Whether these changes increase the risk for NSB is unclear. Thus, we c...

Descripción completa

Detalles Bibliográficos
Autores principales: Klaeske, Kristin, Meyer, Anna L., Saeed, Diyar, Eifert, Sandra, Jawad, Khalil, Sieg, Franz, Haunschild, Josephina, Borger, Michael A., Dieterlen, Maja-Theresa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9499488/
https://www.ncbi.nlm.nih.gov/pubmed/36142161
http://dx.doi.org/10.3390/ijms231810252
_version_ 1784795003370864640
author Klaeske, Kristin
Meyer, Anna L.
Saeed, Diyar
Eifert, Sandra
Jawad, Khalil
Sieg, Franz
Haunschild, Josephina
Borger, Michael A.
Dieterlen, Maja-Theresa
author_facet Klaeske, Kristin
Meyer, Anna L.
Saeed, Diyar
Eifert, Sandra
Jawad, Khalil
Sieg, Franz
Haunschild, Josephina
Borger, Michael A.
Dieterlen, Maja-Theresa
author_sort Klaeske, Kristin
collection PubMed
description Non-surgical bleeding (NSB) is one of the major clinical complications in patients under continuous-flow left ventricular assist device (LVAD) support. The increased shear stress leads to an altered platelet receptor composition. Whether these changes increase the risk for NSB is unclear. Thus, we compared the platelet receptor composition of patients with (bleeder group, n = 18) and without NSB (non-bleeder group, n = 18) prior to LVAD implantation. Blood samples were obtained prior to LVAD implantation and after bleeding complications in the post-implant period. Platelet receptor expression of GPIbα, GPIIb/IIIa, P-selectin and CD63 as well as intra-platelet oxidative stress levels were quantified by flow cytometry. Bleeders and non-bleeders were comparable regarding clinical characteristics, von Willebrand factor diagnostics and the aggregation capacity before and after LVAD implantation (p > 0.05). LVAD patients in the bleeder group suffered from gastrointestinal bleeding (33%; n = 6), epistaxis (22%; n = 4), hematuria or hematoma (17%; n = 3, respectively) and cerebral bleeding (11%; n = 2). Prior to LVAD implantation, a restricted surface expression of the platelet receptors P-selectin and GPIIb/IIIa was observed in the bleeder group (P-selectin: 7.2 ± 2.6%; GPIIb/IIIa: 26,900 ± 13,608 U) compared to non-bleeders (P-selectin: 12.4 ± 8.1%, p = 0.02; GPIIb/IIIa: 36,259 ± 9914 U; p = 0.02). We hypothesized that the reduced platelet receptor expression of P-selectin and GPIIb/IIIa prior to LVAD implantation may be linked to LVAD-related NSB.
format Online
Article
Text
id pubmed-9499488
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-94994882022-09-23 Decreased Platelet Specific Receptor Expression of P-Selectin and GPIIb/IIIa Predict Future Non-Surgical Bleeding in Patients after Left Ventricular Assist Device Implantation Klaeske, Kristin Meyer, Anna L. Saeed, Diyar Eifert, Sandra Jawad, Khalil Sieg, Franz Haunschild, Josephina Borger, Michael A. Dieterlen, Maja-Theresa Int J Mol Sci Article Non-surgical bleeding (NSB) is one of the major clinical complications in patients under continuous-flow left ventricular assist device (LVAD) support. The increased shear stress leads to an altered platelet receptor composition. Whether these changes increase the risk for NSB is unclear. Thus, we compared the platelet receptor composition of patients with (bleeder group, n = 18) and without NSB (non-bleeder group, n = 18) prior to LVAD implantation. Blood samples were obtained prior to LVAD implantation and after bleeding complications in the post-implant period. Platelet receptor expression of GPIbα, GPIIb/IIIa, P-selectin and CD63 as well as intra-platelet oxidative stress levels were quantified by flow cytometry. Bleeders and non-bleeders were comparable regarding clinical characteristics, von Willebrand factor diagnostics and the aggregation capacity before and after LVAD implantation (p > 0.05). LVAD patients in the bleeder group suffered from gastrointestinal bleeding (33%; n = 6), epistaxis (22%; n = 4), hematuria or hematoma (17%; n = 3, respectively) and cerebral bleeding (11%; n = 2). Prior to LVAD implantation, a restricted surface expression of the platelet receptors P-selectin and GPIIb/IIIa was observed in the bleeder group (P-selectin: 7.2 ± 2.6%; GPIIb/IIIa: 26,900 ± 13,608 U) compared to non-bleeders (P-selectin: 12.4 ± 8.1%, p = 0.02; GPIIb/IIIa: 36,259 ± 9914 U; p = 0.02). We hypothesized that the reduced platelet receptor expression of P-selectin and GPIIb/IIIa prior to LVAD implantation may be linked to LVAD-related NSB. MDPI 2022-09-06 /pmc/articles/PMC9499488/ /pubmed/36142161 http://dx.doi.org/10.3390/ijms231810252 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Klaeske, Kristin
Meyer, Anna L.
Saeed, Diyar
Eifert, Sandra
Jawad, Khalil
Sieg, Franz
Haunschild, Josephina
Borger, Michael A.
Dieterlen, Maja-Theresa
Decreased Platelet Specific Receptor Expression of P-Selectin and GPIIb/IIIa Predict Future Non-Surgical Bleeding in Patients after Left Ventricular Assist Device Implantation
title Decreased Platelet Specific Receptor Expression of P-Selectin and GPIIb/IIIa Predict Future Non-Surgical Bleeding in Patients after Left Ventricular Assist Device Implantation
title_full Decreased Platelet Specific Receptor Expression of P-Selectin and GPIIb/IIIa Predict Future Non-Surgical Bleeding in Patients after Left Ventricular Assist Device Implantation
title_fullStr Decreased Platelet Specific Receptor Expression of P-Selectin and GPIIb/IIIa Predict Future Non-Surgical Bleeding in Patients after Left Ventricular Assist Device Implantation
title_full_unstemmed Decreased Platelet Specific Receptor Expression of P-Selectin and GPIIb/IIIa Predict Future Non-Surgical Bleeding in Patients after Left Ventricular Assist Device Implantation
title_short Decreased Platelet Specific Receptor Expression of P-Selectin and GPIIb/IIIa Predict Future Non-Surgical Bleeding in Patients after Left Ventricular Assist Device Implantation
title_sort decreased platelet specific receptor expression of p-selectin and gpiib/iiia predict future non-surgical bleeding in patients after left ventricular assist device implantation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9499488/
https://www.ncbi.nlm.nih.gov/pubmed/36142161
http://dx.doi.org/10.3390/ijms231810252
work_keys_str_mv AT klaeskekristin decreasedplateletspecificreceptorexpressionofpselectinandgpiibiiiapredictfuturenonsurgicalbleedinginpatientsafterleftventricularassistdeviceimplantation
AT meyerannal decreasedplateletspecificreceptorexpressionofpselectinandgpiibiiiapredictfuturenonsurgicalbleedinginpatientsafterleftventricularassistdeviceimplantation
AT saeeddiyar decreasedplateletspecificreceptorexpressionofpselectinandgpiibiiiapredictfuturenonsurgicalbleedinginpatientsafterleftventricularassistdeviceimplantation
AT eifertsandra decreasedplateletspecificreceptorexpressionofpselectinandgpiibiiiapredictfuturenonsurgicalbleedinginpatientsafterleftventricularassistdeviceimplantation
AT jawadkhalil decreasedplateletspecificreceptorexpressionofpselectinandgpiibiiiapredictfuturenonsurgicalbleedinginpatientsafterleftventricularassistdeviceimplantation
AT siegfranz decreasedplateletspecificreceptorexpressionofpselectinandgpiibiiiapredictfuturenonsurgicalbleedinginpatientsafterleftventricularassistdeviceimplantation
AT haunschildjosephina decreasedplateletspecificreceptorexpressionofpselectinandgpiibiiiapredictfuturenonsurgicalbleedinginpatientsafterleftventricularassistdeviceimplantation
AT borgermichaela decreasedplateletspecificreceptorexpressionofpselectinandgpiibiiiapredictfuturenonsurgicalbleedinginpatientsafterleftventricularassistdeviceimplantation
AT dieterlenmajatheresa decreasedplateletspecificreceptorexpressionofpselectinandgpiibiiiapredictfuturenonsurgicalbleedinginpatientsafterleftventricularassistdeviceimplantation