Navigation accuracy and assessability of carbon fiber-reinforced PEEK instrumentation with multimodal intraoperative imaging in spinal oncology

Radiolucent carbon-fiber reinforced PEEK (CFRP) implants have helped improve oncological follow-up and radiation therapy. Here, we investigated the performance of 3D intraoperative imaging and navigation systems for instrumentation and precision assessment of CFRP pedicle screws across the thoraco-l...

Descripción completa

Detalles Bibliográficos
Autores principales: Hubertus, Vanessa, Wessels, Lars, Früh, Anton, Tkatschenko, Dimitri, Nulis, Irini, Bohner, Georg, Prinz, Vincent, Onken, Julia, Czabanka, Marcus, Vajkoczy, Peter, Hecht, Nils
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9500029/
https://www.ncbi.nlm.nih.gov/pubmed/36138117
http://dx.doi.org/10.1038/s41598-022-20222-7
_version_ 1784795125709275136
author Hubertus, Vanessa
Wessels, Lars
Früh, Anton
Tkatschenko, Dimitri
Nulis, Irini
Bohner, Georg
Prinz, Vincent
Onken, Julia
Czabanka, Marcus
Vajkoczy, Peter
Hecht, Nils
author_facet Hubertus, Vanessa
Wessels, Lars
Früh, Anton
Tkatschenko, Dimitri
Nulis, Irini
Bohner, Georg
Prinz, Vincent
Onken, Julia
Czabanka, Marcus
Vajkoczy, Peter
Hecht, Nils
author_sort Hubertus, Vanessa
collection PubMed
description Radiolucent carbon-fiber reinforced PEEK (CFRP) implants have helped improve oncological follow-up and radiation therapy. Here, we investigated the performance of 3D intraoperative imaging and navigation systems for instrumentation and precision assessment of CFRP pedicle screws across the thoraco-lumbar spine. Thirty-three patients with spinal tumors underwent navigated CFRP instrumentation with intraoperative CT (iCT), robotic cone-beam CT (rCBCT) or cone-beam CT (CBCT) imaging. Two different navigation systems were used for iCT-/rCBCT- and CBCT-based navigation. Demographic, clinical and outcome data was assessed. Four blinded observers rated image quality, assessability and accuracy of CFRP pedicle screws. Inter-observer reliability was determined with Fleiss` Kappa analysis. Between 2018 and 2021, 243 CFRP screws were implanted (iCT:93, rCBCT: 99, CBCT: 51), of which 13 were non-assessable (iCT: 1, rCBCT: 9, CBCT: 3; *p = 0.0475; iCT vs. rCBCT). Navigation accuracy was highest using iCT (74%), followed by rCBCT (69%) and CBCT (49%) (*p = 0.0064; iCT vs. CBCT and rCBCT vs. CBCT). All observers rated iCT image quality higher than rCBCT/CBCT image quality (*p < 0.01) but relevant pedicle breaches were reliably identified with substantial agreement between all observers regardless of the imaging modality. Navigation accuracy for CFRP pedicle screws was considerably lower than expected from reports on titanium implants and CT may be best for reliable assessment of CFRP materials.
format Online
Article
Text
id pubmed-9500029
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-95000292022-09-24 Navigation accuracy and assessability of carbon fiber-reinforced PEEK instrumentation with multimodal intraoperative imaging in spinal oncology Hubertus, Vanessa Wessels, Lars Früh, Anton Tkatschenko, Dimitri Nulis, Irini Bohner, Georg Prinz, Vincent Onken, Julia Czabanka, Marcus Vajkoczy, Peter Hecht, Nils Sci Rep Article Radiolucent carbon-fiber reinforced PEEK (CFRP) implants have helped improve oncological follow-up and radiation therapy. Here, we investigated the performance of 3D intraoperative imaging and navigation systems for instrumentation and precision assessment of CFRP pedicle screws across the thoraco-lumbar spine. Thirty-three patients with spinal tumors underwent navigated CFRP instrumentation with intraoperative CT (iCT), robotic cone-beam CT (rCBCT) or cone-beam CT (CBCT) imaging. Two different navigation systems were used for iCT-/rCBCT- and CBCT-based navigation. Demographic, clinical and outcome data was assessed. Four blinded observers rated image quality, assessability and accuracy of CFRP pedicle screws. Inter-observer reliability was determined with Fleiss` Kappa analysis. Between 2018 and 2021, 243 CFRP screws were implanted (iCT:93, rCBCT: 99, CBCT: 51), of which 13 were non-assessable (iCT: 1, rCBCT: 9, CBCT: 3; *p = 0.0475; iCT vs. rCBCT). Navigation accuracy was highest using iCT (74%), followed by rCBCT (69%) and CBCT (49%) (*p = 0.0064; iCT vs. CBCT and rCBCT vs. CBCT). All observers rated iCT image quality higher than rCBCT/CBCT image quality (*p < 0.01) but relevant pedicle breaches were reliably identified with substantial agreement between all observers regardless of the imaging modality. Navigation accuracy for CFRP pedicle screws was considerably lower than expected from reports on titanium implants and CT may be best for reliable assessment of CFRP materials. Nature Publishing Group UK 2022-09-22 /pmc/articles/PMC9500029/ /pubmed/36138117 http://dx.doi.org/10.1038/s41598-022-20222-7 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Hubertus, Vanessa
Wessels, Lars
Früh, Anton
Tkatschenko, Dimitri
Nulis, Irini
Bohner, Georg
Prinz, Vincent
Onken, Julia
Czabanka, Marcus
Vajkoczy, Peter
Hecht, Nils
Navigation accuracy and assessability of carbon fiber-reinforced PEEK instrumentation with multimodal intraoperative imaging in spinal oncology
title Navigation accuracy and assessability of carbon fiber-reinforced PEEK instrumentation with multimodal intraoperative imaging in spinal oncology
title_full Navigation accuracy and assessability of carbon fiber-reinforced PEEK instrumentation with multimodal intraoperative imaging in spinal oncology
title_fullStr Navigation accuracy and assessability of carbon fiber-reinforced PEEK instrumentation with multimodal intraoperative imaging in spinal oncology
title_full_unstemmed Navigation accuracy and assessability of carbon fiber-reinforced PEEK instrumentation with multimodal intraoperative imaging in spinal oncology
title_short Navigation accuracy and assessability of carbon fiber-reinforced PEEK instrumentation with multimodal intraoperative imaging in spinal oncology
title_sort navigation accuracy and assessability of carbon fiber-reinforced peek instrumentation with multimodal intraoperative imaging in spinal oncology
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9500029/
https://www.ncbi.nlm.nih.gov/pubmed/36138117
http://dx.doi.org/10.1038/s41598-022-20222-7
work_keys_str_mv AT hubertusvanessa navigationaccuracyandassessabilityofcarbonfiberreinforcedpeekinstrumentationwithmultimodalintraoperativeimaginginspinaloncology
AT wesselslars navigationaccuracyandassessabilityofcarbonfiberreinforcedpeekinstrumentationwithmultimodalintraoperativeimaginginspinaloncology
AT fruhanton navigationaccuracyandassessabilityofcarbonfiberreinforcedpeekinstrumentationwithmultimodalintraoperativeimaginginspinaloncology
AT tkatschenkodimitri navigationaccuracyandassessabilityofcarbonfiberreinforcedpeekinstrumentationwithmultimodalintraoperativeimaginginspinaloncology
AT nulisirini navigationaccuracyandassessabilityofcarbonfiberreinforcedpeekinstrumentationwithmultimodalintraoperativeimaginginspinaloncology
AT bohnergeorg navigationaccuracyandassessabilityofcarbonfiberreinforcedpeekinstrumentationwithmultimodalintraoperativeimaginginspinaloncology
AT prinzvincent navigationaccuracyandassessabilityofcarbonfiberreinforcedpeekinstrumentationwithmultimodalintraoperativeimaginginspinaloncology
AT onkenjulia navigationaccuracyandassessabilityofcarbonfiberreinforcedpeekinstrumentationwithmultimodalintraoperativeimaginginspinaloncology
AT czabankamarcus navigationaccuracyandassessabilityofcarbonfiberreinforcedpeekinstrumentationwithmultimodalintraoperativeimaginginspinaloncology
AT vajkoczypeter navigationaccuracyandassessabilityofcarbonfiberreinforcedpeekinstrumentationwithmultimodalintraoperativeimaginginspinaloncology
AT hechtnils navigationaccuracyandassessabilityofcarbonfiberreinforcedpeekinstrumentationwithmultimodalintraoperativeimaginginspinaloncology