Cargando…
Navigation accuracy and assessability of carbon fiber-reinforced PEEK instrumentation with multimodal intraoperative imaging in spinal oncology
Radiolucent carbon-fiber reinforced PEEK (CFRP) implants have helped improve oncological follow-up and radiation therapy. Here, we investigated the performance of 3D intraoperative imaging and navigation systems for instrumentation and precision assessment of CFRP pedicle screws across the thoraco-l...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9500029/ https://www.ncbi.nlm.nih.gov/pubmed/36138117 http://dx.doi.org/10.1038/s41598-022-20222-7 |
_version_ | 1784795125709275136 |
---|---|
author | Hubertus, Vanessa Wessels, Lars Früh, Anton Tkatschenko, Dimitri Nulis, Irini Bohner, Georg Prinz, Vincent Onken, Julia Czabanka, Marcus Vajkoczy, Peter Hecht, Nils |
author_facet | Hubertus, Vanessa Wessels, Lars Früh, Anton Tkatschenko, Dimitri Nulis, Irini Bohner, Georg Prinz, Vincent Onken, Julia Czabanka, Marcus Vajkoczy, Peter Hecht, Nils |
author_sort | Hubertus, Vanessa |
collection | PubMed |
description | Radiolucent carbon-fiber reinforced PEEK (CFRP) implants have helped improve oncological follow-up and radiation therapy. Here, we investigated the performance of 3D intraoperative imaging and navigation systems for instrumentation and precision assessment of CFRP pedicle screws across the thoraco-lumbar spine. Thirty-three patients with spinal tumors underwent navigated CFRP instrumentation with intraoperative CT (iCT), robotic cone-beam CT (rCBCT) or cone-beam CT (CBCT) imaging. Two different navigation systems were used for iCT-/rCBCT- and CBCT-based navigation. Demographic, clinical and outcome data was assessed. Four blinded observers rated image quality, assessability and accuracy of CFRP pedicle screws. Inter-observer reliability was determined with Fleiss` Kappa analysis. Between 2018 and 2021, 243 CFRP screws were implanted (iCT:93, rCBCT: 99, CBCT: 51), of which 13 were non-assessable (iCT: 1, rCBCT: 9, CBCT: 3; *p = 0.0475; iCT vs. rCBCT). Navigation accuracy was highest using iCT (74%), followed by rCBCT (69%) and CBCT (49%) (*p = 0.0064; iCT vs. CBCT and rCBCT vs. CBCT). All observers rated iCT image quality higher than rCBCT/CBCT image quality (*p < 0.01) but relevant pedicle breaches were reliably identified with substantial agreement between all observers regardless of the imaging modality. Navigation accuracy for CFRP pedicle screws was considerably lower than expected from reports on titanium implants and CT may be best for reliable assessment of CFRP materials. |
format | Online Article Text |
id | pubmed-9500029 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-95000292022-09-24 Navigation accuracy and assessability of carbon fiber-reinforced PEEK instrumentation with multimodal intraoperative imaging in spinal oncology Hubertus, Vanessa Wessels, Lars Früh, Anton Tkatschenko, Dimitri Nulis, Irini Bohner, Georg Prinz, Vincent Onken, Julia Czabanka, Marcus Vajkoczy, Peter Hecht, Nils Sci Rep Article Radiolucent carbon-fiber reinforced PEEK (CFRP) implants have helped improve oncological follow-up and radiation therapy. Here, we investigated the performance of 3D intraoperative imaging and navigation systems for instrumentation and precision assessment of CFRP pedicle screws across the thoraco-lumbar spine. Thirty-three patients with spinal tumors underwent navigated CFRP instrumentation with intraoperative CT (iCT), robotic cone-beam CT (rCBCT) or cone-beam CT (CBCT) imaging. Two different navigation systems were used for iCT-/rCBCT- and CBCT-based navigation. Demographic, clinical and outcome data was assessed. Four blinded observers rated image quality, assessability and accuracy of CFRP pedicle screws. Inter-observer reliability was determined with Fleiss` Kappa analysis. Between 2018 and 2021, 243 CFRP screws were implanted (iCT:93, rCBCT: 99, CBCT: 51), of which 13 were non-assessable (iCT: 1, rCBCT: 9, CBCT: 3; *p = 0.0475; iCT vs. rCBCT). Navigation accuracy was highest using iCT (74%), followed by rCBCT (69%) and CBCT (49%) (*p = 0.0064; iCT vs. CBCT and rCBCT vs. CBCT). All observers rated iCT image quality higher than rCBCT/CBCT image quality (*p < 0.01) but relevant pedicle breaches were reliably identified with substantial agreement between all observers regardless of the imaging modality. Navigation accuracy for CFRP pedicle screws was considerably lower than expected from reports on titanium implants and CT may be best for reliable assessment of CFRP materials. Nature Publishing Group UK 2022-09-22 /pmc/articles/PMC9500029/ /pubmed/36138117 http://dx.doi.org/10.1038/s41598-022-20222-7 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Hubertus, Vanessa Wessels, Lars Früh, Anton Tkatschenko, Dimitri Nulis, Irini Bohner, Georg Prinz, Vincent Onken, Julia Czabanka, Marcus Vajkoczy, Peter Hecht, Nils Navigation accuracy and assessability of carbon fiber-reinforced PEEK instrumentation with multimodal intraoperative imaging in spinal oncology |
title | Navigation accuracy and assessability of carbon fiber-reinforced PEEK instrumentation with multimodal intraoperative imaging in spinal oncology |
title_full | Navigation accuracy and assessability of carbon fiber-reinforced PEEK instrumentation with multimodal intraoperative imaging in spinal oncology |
title_fullStr | Navigation accuracy and assessability of carbon fiber-reinforced PEEK instrumentation with multimodal intraoperative imaging in spinal oncology |
title_full_unstemmed | Navigation accuracy and assessability of carbon fiber-reinforced PEEK instrumentation with multimodal intraoperative imaging in spinal oncology |
title_short | Navigation accuracy and assessability of carbon fiber-reinforced PEEK instrumentation with multimodal intraoperative imaging in spinal oncology |
title_sort | navigation accuracy and assessability of carbon fiber-reinforced peek instrumentation with multimodal intraoperative imaging in spinal oncology |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9500029/ https://www.ncbi.nlm.nih.gov/pubmed/36138117 http://dx.doi.org/10.1038/s41598-022-20222-7 |
work_keys_str_mv | AT hubertusvanessa navigationaccuracyandassessabilityofcarbonfiberreinforcedpeekinstrumentationwithmultimodalintraoperativeimaginginspinaloncology AT wesselslars navigationaccuracyandassessabilityofcarbonfiberreinforcedpeekinstrumentationwithmultimodalintraoperativeimaginginspinaloncology AT fruhanton navigationaccuracyandassessabilityofcarbonfiberreinforcedpeekinstrumentationwithmultimodalintraoperativeimaginginspinaloncology AT tkatschenkodimitri navigationaccuracyandassessabilityofcarbonfiberreinforcedpeekinstrumentationwithmultimodalintraoperativeimaginginspinaloncology AT nulisirini navigationaccuracyandassessabilityofcarbonfiberreinforcedpeekinstrumentationwithmultimodalintraoperativeimaginginspinaloncology AT bohnergeorg navigationaccuracyandassessabilityofcarbonfiberreinforcedpeekinstrumentationwithmultimodalintraoperativeimaginginspinaloncology AT prinzvincent navigationaccuracyandassessabilityofcarbonfiberreinforcedpeekinstrumentationwithmultimodalintraoperativeimaginginspinaloncology AT onkenjulia navigationaccuracyandassessabilityofcarbonfiberreinforcedpeekinstrumentationwithmultimodalintraoperativeimaginginspinaloncology AT czabankamarcus navigationaccuracyandassessabilityofcarbonfiberreinforcedpeekinstrumentationwithmultimodalintraoperativeimaginginspinaloncology AT vajkoczypeter navigationaccuracyandassessabilityofcarbonfiberreinforcedpeekinstrumentationwithmultimodalintraoperativeimaginginspinaloncology AT hechtnils navigationaccuracyandassessabilityofcarbonfiberreinforcedpeekinstrumentationwithmultimodalintraoperativeimaginginspinaloncology |