Cargando…

Angiographic Characteristics of the Vein of Marshall in Patients with and without Atrial Fibrillation

Background: Ethanol infusion into the vein of Marshall (Et-VOM) is a novel therapeutic treatment for atrial fibrillation (AF). However, few studies have focused on the difference between AF and non-AF patients (presented other types of arrhythmias) regarding the characteristics of the vein of Marsha...

Descripción completa

Detalles Bibliográficos
Autores principales: Ding, Lei, Zhang, Hongda, Yu, Fengyuan, Mi, Lijie, Hua, Wei, Zhang, Shu, Yao, Yan, Tang, Min
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9502660/
https://www.ncbi.nlm.nih.gov/pubmed/36143031
http://dx.doi.org/10.3390/jcm11185384
_version_ 1784795761365483520
author Ding, Lei
Zhang, Hongda
Yu, Fengyuan
Mi, Lijie
Hua, Wei
Zhang, Shu
Yao, Yan
Tang, Min
author_facet Ding, Lei
Zhang, Hongda
Yu, Fengyuan
Mi, Lijie
Hua, Wei
Zhang, Shu
Yao, Yan
Tang, Min
author_sort Ding, Lei
collection PubMed
description Background: Ethanol infusion into the vein of Marshall (Et-VOM) is a novel therapeutic treatment for atrial fibrillation (AF). However, few studies have focused on the difference between AF and non-AF patients (presented other types of arrhythmias) regarding the characteristics of the vein of Marshall (VOM). Objective: This study sought to investigate the incidence, morphology, and angiographic characteristics of the VOM. Methods: Coronary sinus (CS) angiography was performed in all patients. The baseline, angiographic characteristics and measurements of VOM dimensions were compared between the AF and non-AF group. Results: CS angiography was performed in 290 patients. The VOM detection rate was higher in the AF group than in the non-AF group (91.8% vs. 84.1%, p = 0.044). In the right anterior oblique (RAO) projection, AF patients had significant larger VOM ostium, CS ostium, and CS diameter at VOM ostium than non-AF patients (1.9 ± 0.9 vs. 1.7 ± 0.7 mm, p = 0.015; 12.8 ± 4.1 vs. 11.4 ± 3.7 mm, p = 0.016; 9.1 ± 3.1 vs. 8.2 ± 2.9 mm, p = 0.028, respectively). There was a slight linear correlation between the VOM ostium and the CS ostium diameter as well as left atrial volume (LAV). Conclusion: AF patients seem to have a higher incidence of the VOM, larger VOM ostium, CS ostium, and CS lumen in RAO view. Meanwhile, the VOM ostium may correlate with the CS ostium and LAV.
format Online
Article
Text
id pubmed-9502660
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-95026602022-09-24 Angiographic Characteristics of the Vein of Marshall in Patients with and without Atrial Fibrillation Ding, Lei Zhang, Hongda Yu, Fengyuan Mi, Lijie Hua, Wei Zhang, Shu Yao, Yan Tang, Min J Clin Med Article Background: Ethanol infusion into the vein of Marshall (Et-VOM) is a novel therapeutic treatment for atrial fibrillation (AF). However, few studies have focused on the difference between AF and non-AF patients (presented other types of arrhythmias) regarding the characteristics of the vein of Marshall (VOM). Objective: This study sought to investigate the incidence, morphology, and angiographic characteristics of the VOM. Methods: Coronary sinus (CS) angiography was performed in all patients. The baseline, angiographic characteristics and measurements of VOM dimensions were compared between the AF and non-AF group. Results: CS angiography was performed in 290 patients. The VOM detection rate was higher in the AF group than in the non-AF group (91.8% vs. 84.1%, p = 0.044). In the right anterior oblique (RAO) projection, AF patients had significant larger VOM ostium, CS ostium, and CS diameter at VOM ostium than non-AF patients (1.9 ± 0.9 vs. 1.7 ± 0.7 mm, p = 0.015; 12.8 ± 4.1 vs. 11.4 ± 3.7 mm, p = 0.016; 9.1 ± 3.1 vs. 8.2 ± 2.9 mm, p = 0.028, respectively). There was a slight linear correlation between the VOM ostium and the CS ostium diameter as well as left atrial volume (LAV). Conclusion: AF patients seem to have a higher incidence of the VOM, larger VOM ostium, CS ostium, and CS lumen in RAO view. Meanwhile, the VOM ostium may correlate with the CS ostium and LAV. MDPI 2022-09-14 /pmc/articles/PMC9502660/ /pubmed/36143031 http://dx.doi.org/10.3390/jcm11185384 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ding, Lei
Zhang, Hongda
Yu, Fengyuan
Mi, Lijie
Hua, Wei
Zhang, Shu
Yao, Yan
Tang, Min
Angiographic Characteristics of the Vein of Marshall in Patients with and without Atrial Fibrillation
title Angiographic Characteristics of the Vein of Marshall in Patients with and without Atrial Fibrillation
title_full Angiographic Characteristics of the Vein of Marshall in Patients with and without Atrial Fibrillation
title_fullStr Angiographic Characteristics of the Vein of Marshall in Patients with and without Atrial Fibrillation
title_full_unstemmed Angiographic Characteristics of the Vein of Marshall in Patients with and without Atrial Fibrillation
title_short Angiographic Characteristics of the Vein of Marshall in Patients with and without Atrial Fibrillation
title_sort angiographic characteristics of the vein of marshall in patients with and without atrial fibrillation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9502660/
https://www.ncbi.nlm.nih.gov/pubmed/36143031
http://dx.doi.org/10.3390/jcm11185384
work_keys_str_mv AT dinglei angiographiccharacteristicsoftheveinofmarshallinpatientswithandwithoutatrialfibrillation
AT zhanghongda angiographiccharacteristicsoftheveinofmarshallinpatientswithandwithoutatrialfibrillation
AT yufengyuan angiographiccharacteristicsoftheveinofmarshallinpatientswithandwithoutatrialfibrillation
AT milijie angiographiccharacteristicsoftheveinofmarshallinpatientswithandwithoutatrialfibrillation
AT huawei angiographiccharacteristicsoftheveinofmarshallinpatientswithandwithoutatrialfibrillation
AT zhangshu angiographiccharacteristicsoftheveinofmarshallinpatientswithandwithoutatrialfibrillation
AT yaoyan angiographiccharacteristicsoftheveinofmarshallinpatientswithandwithoutatrialfibrillation
AT tangmin angiographiccharacteristicsoftheveinofmarshallinpatientswithandwithoutatrialfibrillation