Cargando…

GC-MS/MS Determination of Steroid Hormones in Urine Using Solid-Phase Derivatization as an Alternative to Conventional Methods

Solid-phase analytical derivatization (SPAD) is a promising hybrid sample preparation technique combining the clean-up and preconcentration of the sample in a single step. In this work, a novel SPAD method based on the preparation of trimethylsilyl (TMS) derivatives of steroid hormones (testosterone...

Descripción completa

Detalles Bibliográficos
Autores principales: Temerdashev, Azamat, Nesterenko, Pavel, Dmitrieva, Ekaterina, Zhurkina, Kseniya, Feng, Yu-Qi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9502991/
https://www.ncbi.nlm.nih.gov/pubmed/36144530
http://dx.doi.org/10.3390/molecules27185796
_version_ 1784795852933431296
author Temerdashev, Azamat
Nesterenko, Pavel
Dmitrieva, Ekaterina
Zhurkina, Kseniya
Feng, Yu-Qi
author_facet Temerdashev, Azamat
Nesterenko, Pavel
Dmitrieva, Ekaterina
Zhurkina, Kseniya
Feng, Yu-Qi
author_sort Temerdashev, Azamat
collection PubMed
description Solid-phase analytical derivatization (SPAD) is a promising hybrid sample preparation technique combining the clean-up and preconcentration of the sample in a single step. In this work, a novel SPAD method based on the preparation of trimethylsilyl (TMS) derivatives of steroid hormones (testosterone, estrone, DHT, estriol, estradiol, and progesterone) in Phenomenex Strata C18-E (100 mg, 1 mL) cartridges has been developed and applied for their GC-MS/MS determination in human urine samples. The proposed procedure allows the detection and quantification of steroids with limits of 1.0–2.5 and 2.5–5 ng/mL, respectively. These characteristics are comparable with those obtained with a conventional liquid–liquid extraction, while the recovery of analytes in the proposed SPAD procedure is higher. The major advantages of SPAD are a short derivatization time, high efficiency, and the possibility to automatize the procedure. However, its cost-effectiveness in routine practice is still questionable.
format Online
Article
Text
id pubmed-9502991
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-95029912022-09-24 GC-MS/MS Determination of Steroid Hormones in Urine Using Solid-Phase Derivatization as an Alternative to Conventional Methods Temerdashev, Azamat Nesterenko, Pavel Dmitrieva, Ekaterina Zhurkina, Kseniya Feng, Yu-Qi Molecules Article Solid-phase analytical derivatization (SPAD) is a promising hybrid sample preparation technique combining the clean-up and preconcentration of the sample in a single step. In this work, a novel SPAD method based on the preparation of trimethylsilyl (TMS) derivatives of steroid hormones (testosterone, estrone, DHT, estriol, estradiol, and progesterone) in Phenomenex Strata C18-E (100 mg, 1 mL) cartridges has been developed and applied for their GC-MS/MS determination in human urine samples. The proposed procedure allows the detection and quantification of steroids with limits of 1.0–2.5 and 2.5–5 ng/mL, respectively. These characteristics are comparable with those obtained with a conventional liquid–liquid extraction, while the recovery of analytes in the proposed SPAD procedure is higher. The major advantages of SPAD are a short derivatization time, high efficiency, and the possibility to automatize the procedure. However, its cost-effectiveness in routine practice is still questionable. MDPI 2022-09-07 /pmc/articles/PMC9502991/ /pubmed/36144530 http://dx.doi.org/10.3390/molecules27185796 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Temerdashev, Azamat
Nesterenko, Pavel
Dmitrieva, Ekaterina
Zhurkina, Kseniya
Feng, Yu-Qi
GC-MS/MS Determination of Steroid Hormones in Urine Using Solid-Phase Derivatization as an Alternative to Conventional Methods
title GC-MS/MS Determination of Steroid Hormones in Urine Using Solid-Phase Derivatization as an Alternative to Conventional Methods
title_full GC-MS/MS Determination of Steroid Hormones in Urine Using Solid-Phase Derivatization as an Alternative to Conventional Methods
title_fullStr GC-MS/MS Determination of Steroid Hormones in Urine Using Solid-Phase Derivatization as an Alternative to Conventional Methods
title_full_unstemmed GC-MS/MS Determination of Steroid Hormones in Urine Using Solid-Phase Derivatization as an Alternative to Conventional Methods
title_short GC-MS/MS Determination of Steroid Hormones in Urine Using Solid-Phase Derivatization as an Alternative to Conventional Methods
title_sort gc-ms/ms determination of steroid hormones in urine using solid-phase derivatization as an alternative to conventional methods
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9502991/
https://www.ncbi.nlm.nih.gov/pubmed/36144530
http://dx.doi.org/10.3390/molecules27185796
work_keys_str_mv AT temerdashevazamat gcmsmsdeterminationofsteroidhormonesinurineusingsolidphasederivatizationasanalternativetoconventionalmethods
AT nesterenkopavel gcmsmsdeterminationofsteroidhormonesinurineusingsolidphasederivatizationasanalternativetoconventionalmethods
AT dmitrievaekaterina gcmsmsdeterminationofsteroidhormonesinurineusingsolidphasederivatizationasanalternativetoconventionalmethods
AT zhurkinakseniya gcmsmsdeterminationofsteroidhormonesinurineusingsolidphasederivatizationasanalternativetoconventionalmethods
AT fengyuqi gcmsmsdeterminationofsteroidhormonesinurineusingsolidphasederivatizationasanalternativetoconventionalmethods