Cargando…

Stability Analysis of Two Power Converters Control Algorithms Connected to Micro-Grids with Wide Frequency Variation

Distributed power generation, micro-grids, and networks working in islanding mode have strong deviations in voltage quantities. These deviations can be divided into amplitude and frequency. Amplitude deviations are well-known and studied, as they are common in small and big grids. However, deviation...

Descripción completa

Detalles Bibliográficos
Autores principales: Rohten, Jaime, Villarroel, Felipe, Pulido, Esteban, Muñoz, Javier, Silva, José, Perez, Marcelo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9503461/
https://www.ncbi.nlm.nih.gov/pubmed/36146425
http://dx.doi.org/10.3390/s22187078
_version_ 1784795968986677248
author Rohten, Jaime
Villarroel, Felipe
Pulido, Esteban
Muñoz, Javier
Silva, José
Perez, Marcelo
author_facet Rohten, Jaime
Villarroel, Felipe
Pulido, Esteban
Muñoz, Javier
Silva, José
Perez, Marcelo
author_sort Rohten, Jaime
collection PubMed
description Distributed power generation, micro-grids, and networks working in islanding mode have strong deviations in voltage quantities. These deviations can be divided into amplitude and frequency. Amplitude deviations are well-known and studied, as they are common in small and big grids. However, deviations on the ac mains frequency have not been widely studied. The literature shows control schemes capable of bearing these variations, but no systematic analysis has been performed to ensure stability. As the majority of power converters are designed for big grids, their analysis and design neglect frequency disturbances, therefore those devices allow a very small frequency operating window. For instance, in power converters that need to be synchronized to the grid, the standard deviation does not go beyond 0.5 Hz, and for grid-tied inverters it does not go beyond 1 Hz, whereas variations of around 8 Hz can be expected in micro-grids. This work presents a comprehensive analysis of the control system’s stability, where two different control schemes for a back-to-back static converter topology are implemented and studied under a wide variable grid frequency. Because the behavior of power converters is nonlinear and coupled, dynamic and static decouplers are usually introduced in the controller, being a key element on the scheme according to the findings. The results show that using just a static decoupler does not guarantee stability under frequency variations; meanwhile, when a dynamic decoupler is used, the operating window can be greatly extended. The procedure shown in this paper can also be extended to other control algorithms, making it possible to carefully choose the control system for a variable frequency condition. Simulated and experimental results confirm the theoretical approach.
format Online
Article
Text
id pubmed-9503461
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-95034612022-09-24 Stability Analysis of Two Power Converters Control Algorithms Connected to Micro-Grids with Wide Frequency Variation Rohten, Jaime Villarroel, Felipe Pulido, Esteban Muñoz, Javier Silva, José Perez, Marcelo Sensors (Basel) Article Distributed power generation, micro-grids, and networks working in islanding mode have strong deviations in voltage quantities. These deviations can be divided into amplitude and frequency. Amplitude deviations are well-known and studied, as they are common in small and big grids. However, deviations on the ac mains frequency have not been widely studied. The literature shows control schemes capable of bearing these variations, but no systematic analysis has been performed to ensure stability. As the majority of power converters are designed for big grids, their analysis and design neglect frequency disturbances, therefore those devices allow a very small frequency operating window. For instance, in power converters that need to be synchronized to the grid, the standard deviation does not go beyond 0.5 Hz, and for grid-tied inverters it does not go beyond 1 Hz, whereas variations of around 8 Hz can be expected in micro-grids. This work presents a comprehensive analysis of the control system’s stability, where two different control schemes for a back-to-back static converter topology are implemented and studied under a wide variable grid frequency. Because the behavior of power converters is nonlinear and coupled, dynamic and static decouplers are usually introduced in the controller, being a key element on the scheme according to the findings. The results show that using just a static decoupler does not guarantee stability under frequency variations; meanwhile, when a dynamic decoupler is used, the operating window can be greatly extended. The procedure shown in this paper can also be extended to other control algorithms, making it possible to carefully choose the control system for a variable frequency condition. Simulated and experimental results confirm the theoretical approach. MDPI 2022-09-19 /pmc/articles/PMC9503461/ /pubmed/36146425 http://dx.doi.org/10.3390/s22187078 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Rohten, Jaime
Villarroel, Felipe
Pulido, Esteban
Muñoz, Javier
Silva, José
Perez, Marcelo
Stability Analysis of Two Power Converters Control Algorithms Connected to Micro-Grids with Wide Frequency Variation
title Stability Analysis of Two Power Converters Control Algorithms Connected to Micro-Grids with Wide Frequency Variation
title_full Stability Analysis of Two Power Converters Control Algorithms Connected to Micro-Grids with Wide Frequency Variation
title_fullStr Stability Analysis of Two Power Converters Control Algorithms Connected to Micro-Grids with Wide Frequency Variation
title_full_unstemmed Stability Analysis of Two Power Converters Control Algorithms Connected to Micro-Grids with Wide Frequency Variation
title_short Stability Analysis of Two Power Converters Control Algorithms Connected to Micro-Grids with Wide Frequency Variation
title_sort stability analysis of two power converters control algorithms connected to micro-grids with wide frequency variation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9503461/
https://www.ncbi.nlm.nih.gov/pubmed/36146425
http://dx.doi.org/10.3390/s22187078
work_keys_str_mv AT rohtenjaime stabilityanalysisoftwopowerconverterscontrolalgorithmsconnectedtomicrogridswithwidefrequencyvariation
AT villarroelfelipe stabilityanalysisoftwopowerconverterscontrolalgorithmsconnectedtomicrogridswithwidefrequencyvariation
AT pulidoesteban stabilityanalysisoftwopowerconverterscontrolalgorithmsconnectedtomicrogridswithwidefrequencyvariation
AT munozjavier stabilityanalysisoftwopowerconverterscontrolalgorithmsconnectedtomicrogridswithwidefrequencyvariation
AT silvajose stabilityanalysisoftwopowerconverterscontrolalgorithmsconnectedtomicrogridswithwidefrequencyvariation
AT perezmarcelo stabilityanalysisoftwopowerconverterscontrolalgorithmsconnectedtomicrogridswithwidefrequencyvariation