Cargando…
Dual-Energy CT of the Heart: A Review
Dual-energy computed tomography (DECT) represents an emerging imaging technique which consists of the acquisition of two separate datasets utilizing two different X-ray spectra energies. Several cardiac DECT applications have been assessed, such as virtual monoenergetic images, virtual non-contrast...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9503750/ https://www.ncbi.nlm.nih.gov/pubmed/36135402 http://dx.doi.org/10.3390/jimaging8090236 |
_version_ | 1784796042793844736 |
---|---|
author | Dell’Aversana, Serena Ascione, Raffaele De Giorgi, Marco De Lucia, Davide Raffaele Cuocolo, Renato Boccalatte, Marco Sibilio, Gerolamo Napolitano, Giovanni Muscogiuri, Giuseppe Sironi, Sandro Di Costanzo, Giuseppe Cavaglià, Enrico Imbriaco, Massimo Ponsiglione, Andrea |
author_facet | Dell’Aversana, Serena Ascione, Raffaele De Giorgi, Marco De Lucia, Davide Raffaele Cuocolo, Renato Boccalatte, Marco Sibilio, Gerolamo Napolitano, Giovanni Muscogiuri, Giuseppe Sironi, Sandro Di Costanzo, Giuseppe Cavaglià, Enrico Imbriaco, Massimo Ponsiglione, Andrea |
author_sort | Dell’Aversana, Serena |
collection | PubMed |
description | Dual-energy computed tomography (DECT) represents an emerging imaging technique which consists of the acquisition of two separate datasets utilizing two different X-ray spectra energies. Several cardiac DECT applications have been assessed, such as virtual monoenergetic images, virtual non-contrast reconstructions, and iodine myocardial perfusion maps, which are demonstrated to improve diagnostic accuracy and image quality while reducing both radiation and contrast media administration. This review will summarize the technical basis of DECT and review the principal cardiac applications currently adopted in clinical practice, exploring possible future applications. |
format | Online Article Text |
id | pubmed-9503750 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-95037502022-09-24 Dual-Energy CT of the Heart: A Review Dell’Aversana, Serena Ascione, Raffaele De Giorgi, Marco De Lucia, Davide Raffaele Cuocolo, Renato Boccalatte, Marco Sibilio, Gerolamo Napolitano, Giovanni Muscogiuri, Giuseppe Sironi, Sandro Di Costanzo, Giuseppe Cavaglià, Enrico Imbriaco, Massimo Ponsiglione, Andrea J Imaging Review Dual-energy computed tomography (DECT) represents an emerging imaging technique which consists of the acquisition of two separate datasets utilizing two different X-ray spectra energies. Several cardiac DECT applications have been assessed, such as virtual monoenergetic images, virtual non-contrast reconstructions, and iodine myocardial perfusion maps, which are demonstrated to improve diagnostic accuracy and image quality while reducing both radiation and contrast media administration. This review will summarize the technical basis of DECT and review the principal cardiac applications currently adopted in clinical practice, exploring possible future applications. MDPI 2022-09-01 /pmc/articles/PMC9503750/ /pubmed/36135402 http://dx.doi.org/10.3390/jimaging8090236 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Review Dell’Aversana, Serena Ascione, Raffaele De Giorgi, Marco De Lucia, Davide Raffaele Cuocolo, Renato Boccalatte, Marco Sibilio, Gerolamo Napolitano, Giovanni Muscogiuri, Giuseppe Sironi, Sandro Di Costanzo, Giuseppe Cavaglià, Enrico Imbriaco, Massimo Ponsiglione, Andrea Dual-Energy CT of the Heart: A Review |
title | Dual-Energy CT of the Heart: A Review |
title_full | Dual-Energy CT of the Heart: A Review |
title_fullStr | Dual-Energy CT of the Heart: A Review |
title_full_unstemmed | Dual-Energy CT of the Heart: A Review |
title_short | Dual-Energy CT of the Heart: A Review |
title_sort | dual-energy ct of the heart: a review |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9503750/ https://www.ncbi.nlm.nih.gov/pubmed/36135402 http://dx.doi.org/10.3390/jimaging8090236 |
work_keys_str_mv | AT dellaversanaserena dualenergyctoftheheartareview AT ascioneraffaele dualenergyctoftheheartareview AT degiorgimarco dualenergyctoftheheartareview AT deluciadavideraffaele dualenergyctoftheheartareview AT cuocolorenato dualenergyctoftheheartareview AT boccalattemarco dualenergyctoftheheartareview AT sibiliogerolamo dualenergyctoftheheartareview AT napolitanogiovanni dualenergyctoftheheartareview AT muscogiurigiuseppe dualenergyctoftheheartareview AT sironisandro dualenergyctoftheheartareview AT dicostanzogiuseppe dualenergyctoftheheartareview AT cavagliaenrico dualenergyctoftheheartareview AT imbriacomassimo dualenergyctoftheheartareview AT ponsiglioneandrea dualenergyctoftheheartareview |