Cargando…
A Comparative Analysis of Dental Measurements in Physical and Digital Orthodontic Case Study Models
Background and Objectives: Study models are essential tools used in the dental teaching process. The aim of the present study was to compare the values obtained by manual and digital orthodontic measurements on physical and digital case study models. Materials and Methods: The physical experimental...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9504461/ https://www.ncbi.nlm.nih.gov/pubmed/36143907 http://dx.doi.org/10.3390/medicina58091230 |
_version_ | 1784796221625335808 |
---|---|
author | Baciu, Elena-Raluca Budală, Dana Gabriela Vasluianu, Roxana-Ionela Lupu, Costin Iulian Murariu, Alice Gelețu, Gabriela Luminița Zetu, Irina Nicoleta Diaconu-Popa, Diana Tatarciuc, Monica Nichitean, Giorgio Luchian, Ionuț |
author_facet | Baciu, Elena-Raluca Budală, Dana Gabriela Vasluianu, Roxana-Ionela Lupu, Costin Iulian Murariu, Alice Gelețu, Gabriela Luminița Zetu, Irina Nicoleta Diaconu-Popa, Diana Tatarciuc, Monica Nichitean, Giorgio Luchian, Ionuț |
author_sort | Baciu, Elena-Raluca |
collection | PubMed |
description | Background and Objectives: Study models are essential tools used in the dental teaching process. The aim of the present study was to compare the values obtained by manual and digital orthodontic measurements on physical and digital case study models. Materials and Methods: The physical experimental models were obtained by traditional pouring (improved stone-type IV gypsum products) and by additive manufacturing (resins). The digital experimental models were created by scanning the physical ones, using a white light-emitting diode (LED) source and an L-shaped dental scanner—Swing DOF (DOF, Seoul, Korea). The physical study models were first measured using a digital caliper, and then, they were scanned and evaluated using the DentalCad 3.0 Galway software (exocad GmbH, Darmstadt, Germany). The Pont, Linder–Harth, and Bolton indices, which are used in orthodontics for training students, were derived using the available data. Results: When comparing the linear measurement mean ranks taken on physical study models to those of digital models, no statistically significant differences (p > 0.05) were found. A similar result was also shown when the dentoalveolar growth indicators were analyzed. Conclusions: It can be concluded that dental study models made by direct light processing (DLP) and pouring type IV class gypsum are both acceptable for orthodontic teaching purposes. |
format | Online Article Text |
id | pubmed-9504461 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-95044612022-09-24 A Comparative Analysis of Dental Measurements in Physical and Digital Orthodontic Case Study Models Baciu, Elena-Raluca Budală, Dana Gabriela Vasluianu, Roxana-Ionela Lupu, Costin Iulian Murariu, Alice Gelețu, Gabriela Luminița Zetu, Irina Nicoleta Diaconu-Popa, Diana Tatarciuc, Monica Nichitean, Giorgio Luchian, Ionuț Medicina (Kaunas) Article Background and Objectives: Study models are essential tools used in the dental teaching process. The aim of the present study was to compare the values obtained by manual and digital orthodontic measurements on physical and digital case study models. Materials and Methods: The physical experimental models were obtained by traditional pouring (improved stone-type IV gypsum products) and by additive manufacturing (resins). The digital experimental models were created by scanning the physical ones, using a white light-emitting diode (LED) source and an L-shaped dental scanner—Swing DOF (DOF, Seoul, Korea). The physical study models were first measured using a digital caliper, and then, they were scanned and evaluated using the DentalCad 3.0 Galway software (exocad GmbH, Darmstadt, Germany). The Pont, Linder–Harth, and Bolton indices, which are used in orthodontics for training students, were derived using the available data. Results: When comparing the linear measurement mean ranks taken on physical study models to those of digital models, no statistically significant differences (p > 0.05) were found. A similar result was also shown when the dentoalveolar growth indicators were analyzed. Conclusions: It can be concluded that dental study models made by direct light processing (DLP) and pouring type IV class gypsum are both acceptable for orthodontic teaching purposes. MDPI 2022-09-06 /pmc/articles/PMC9504461/ /pubmed/36143907 http://dx.doi.org/10.3390/medicina58091230 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Baciu, Elena-Raluca Budală, Dana Gabriela Vasluianu, Roxana-Ionela Lupu, Costin Iulian Murariu, Alice Gelețu, Gabriela Luminița Zetu, Irina Nicoleta Diaconu-Popa, Diana Tatarciuc, Monica Nichitean, Giorgio Luchian, Ionuț A Comparative Analysis of Dental Measurements in Physical and Digital Orthodontic Case Study Models |
title | A Comparative Analysis of Dental Measurements in Physical and Digital Orthodontic Case Study Models |
title_full | A Comparative Analysis of Dental Measurements in Physical and Digital Orthodontic Case Study Models |
title_fullStr | A Comparative Analysis of Dental Measurements in Physical and Digital Orthodontic Case Study Models |
title_full_unstemmed | A Comparative Analysis of Dental Measurements in Physical and Digital Orthodontic Case Study Models |
title_short | A Comparative Analysis of Dental Measurements in Physical and Digital Orthodontic Case Study Models |
title_sort | comparative analysis of dental measurements in physical and digital orthodontic case study models |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9504461/ https://www.ncbi.nlm.nih.gov/pubmed/36143907 http://dx.doi.org/10.3390/medicina58091230 |
work_keys_str_mv | AT baciuelenaraluca acomparativeanalysisofdentalmeasurementsinphysicalanddigitalorthodonticcasestudymodels AT budaladanagabriela acomparativeanalysisofdentalmeasurementsinphysicalanddigitalorthodonticcasestudymodels AT vasluianuroxanaionela acomparativeanalysisofdentalmeasurementsinphysicalanddigitalorthodonticcasestudymodels AT lupucostiniulian acomparativeanalysisofdentalmeasurementsinphysicalanddigitalorthodonticcasestudymodels AT murariualice acomparativeanalysisofdentalmeasurementsinphysicalanddigitalorthodonticcasestudymodels AT geletugabrielaluminita acomparativeanalysisofdentalmeasurementsinphysicalanddigitalorthodonticcasestudymodels AT zetuirinanicoleta acomparativeanalysisofdentalmeasurementsinphysicalanddigitalorthodonticcasestudymodels AT diaconupopadiana acomparativeanalysisofdentalmeasurementsinphysicalanddigitalorthodonticcasestudymodels AT tatarciucmonica acomparativeanalysisofdentalmeasurementsinphysicalanddigitalorthodonticcasestudymodels AT nichiteangiorgio acomparativeanalysisofdentalmeasurementsinphysicalanddigitalorthodonticcasestudymodels AT luchianionut acomparativeanalysisofdentalmeasurementsinphysicalanddigitalorthodonticcasestudymodels AT baciuelenaraluca comparativeanalysisofdentalmeasurementsinphysicalanddigitalorthodonticcasestudymodels AT budaladanagabriela comparativeanalysisofdentalmeasurementsinphysicalanddigitalorthodonticcasestudymodels AT vasluianuroxanaionela comparativeanalysisofdentalmeasurementsinphysicalanddigitalorthodonticcasestudymodels AT lupucostiniulian comparativeanalysisofdentalmeasurementsinphysicalanddigitalorthodonticcasestudymodels AT murariualice comparativeanalysisofdentalmeasurementsinphysicalanddigitalorthodonticcasestudymodels AT geletugabrielaluminita comparativeanalysisofdentalmeasurementsinphysicalanddigitalorthodonticcasestudymodels AT zetuirinanicoleta comparativeanalysisofdentalmeasurementsinphysicalanddigitalorthodonticcasestudymodels AT diaconupopadiana comparativeanalysisofdentalmeasurementsinphysicalanddigitalorthodonticcasestudymodels AT tatarciucmonica comparativeanalysisofdentalmeasurementsinphysicalanddigitalorthodonticcasestudymodels AT nichiteangiorgio comparativeanalysisofdentalmeasurementsinphysicalanddigitalorthodonticcasestudymodels AT luchianionut comparativeanalysisofdentalmeasurementsinphysicalanddigitalorthodonticcasestudymodels |