Cargando…
Plasma-Modified PI Substrate for Highly Reliable Laser-Sintered Copper Films Using Cu(2)O Nanoparticles
Plasma modification of polyimide (PI) substrates upon which electrical circuits are fabricated by the laser sintering of cuprous oxide nanoparticle pastes was investigated systematically in this study. Surface properties of the PI substrate were investigated by carrying out atomic force microscopy (...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9504519/ https://www.ncbi.nlm.nih.gov/pubmed/36145025 http://dx.doi.org/10.3390/nano12183237 |
_version_ | 1784796237339295744 |
---|---|
author | Cheng, Wei-Han Lee, Ming-Tsang Yasuda, Kiyokazu Song, Jenn-Ming |
author_facet | Cheng, Wei-Han Lee, Ming-Tsang Yasuda, Kiyokazu Song, Jenn-Ming |
author_sort | Cheng, Wei-Han |
collection | PubMed |
description | Plasma modification of polyimide (PI) substrates upon which electrical circuits are fabricated by the laser sintering of cuprous oxide nanoparticle pastes was investigated systematically in this study. Surface properties of the PI substrate were investigated by carrying out atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS), and contact angle measurements. Experimental results show that surface characteristics of PI substrates, including surface energy, surface roughness, and surface binding significantly affected the mechanical reliability of the sintered copper structure. Among the plasma gases tested (air, O(2), Ar-5%H(2), and N(2)-30%H(2)), O(2) plasma caused the roughest PI surface as well as the most C=O and C–OH surface binding resulting in an increased polar component of the surface energy. The combination of all those factors caused superior bending fatigue resistance. |
format | Online Article Text |
id | pubmed-9504519 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-95045192022-09-24 Plasma-Modified PI Substrate for Highly Reliable Laser-Sintered Copper Films Using Cu(2)O Nanoparticles Cheng, Wei-Han Lee, Ming-Tsang Yasuda, Kiyokazu Song, Jenn-Ming Nanomaterials (Basel) Article Plasma modification of polyimide (PI) substrates upon which electrical circuits are fabricated by the laser sintering of cuprous oxide nanoparticle pastes was investigated systematically in this study. Surface properties of the PI substrate were investigated by carrying out atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS), and contact angle measurements. Experimental results show that surface characteristics of PI substrates, including surface energy, surface roughness, and surface binding significantly affected the mechanical reliability of the sintered copper structure. Among the plasma gases tested (air, O(2), Ar-5%H(2), and N(2)-30%H(2)), O(2) plasma caused the roughest PI surface as well as the most C=O and C–OH surface binding resulting in an increased polar component of the surface energy. The combination of all those factors caused superior bending fatigue resistance. MDPI 2022-09-18 /pmc/articles/PMC9504519/ /pubmed/36145025 http://dx.doi.org/10.3390/nano12183237 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Cheng, Wei-Han Lee, Ming-Tsang Yasuda, Kiyokazu Song, Jenn-Ming Plasma-Modified PI Substrate for Highly Reliable Laser-Sintered Copper Films Using Cu(2)O Nanoparticles |
title | Plasma-Modified PI Substrate for Highly Reliable Laser-Sintered Copper Films Using Cu(2)O Nanoparticles |
title_full | Plasma-Modified PI Substrate for Highly Reliable Laser-Sintered Copper Films Using Cu(2)O Nanoparticles |
title_fullStr | Plasma-Modified PI Substrate for Highly Reliable Laser-Sintered Copper Films Using Cu(2)O Nanoparticles |
title_full_unstemmed | Plasma-Modified PI Substrate for Highly Reliable Laser-Sintered Copper Films Using Cu(2)O Nanoparticles |
title_short | Plasma-Modified PI Substrate for Highly Reliable Laser-Sintered Copper Films Using Cu(2)O Nanoparticles |
title_sort | plasma-modified pi substrate for highly reliable laser-sintered copper films using cu(2)o nanoparticles |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9504519/ https://www.ncbi.nlm.nih.gov/pubmed/36145025 http://dx.doi.org/10.3390/nano12183237 |
work_keys_str_mv | AT chengweihan plasmamodifiedpisubstrateforhighlyreliablelasersinteredcopperfilmsusingcu2onanoparticles AT leemingtsang plasmamodifiedpisubstrateforhighlyreliablelasersinteredcopperfilmsusingcu2onanoparticles AT yasudakiyokazu plasmamodifiedpisubstrateforhighlyreliablelasersinteredcopperfilmsusingcu2onanoparticles AT songjennming plasmamodifiedpisubstrateforhighlyreliablelasersinteredcopperfilmsusingcu2onanoparticles |