Cargando…

Characterization of the Plastic Scintillator Detector System Exradin W2 in a High Dose Rate Flattening-Filter-Free Photon Beam

(1) Background: The Exradin W2 is a commercially available scintillator detector designed for reference and relative dosimetry in small fields. In this work, we investigated the performance of the W2 scintillator in a 10 MV flattening-filter-free photon beam and compared it to the performance of ion...

Descripción completa

Detalles Bibliográficos
Autores principales: Thrower, Sara, Prajapati, Surendra, Holmes, Shannon, Schüler, Emil, Beddar, Sam
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9505273/
https://www.ncbi.nlm.nih.gov/pubmed/36146135
http://dx.doi.org/10.3390/s22186785
_version_ 1784796431143403520
author Thrower, Sara
Prajapati, Surendra
Holmes, Shannon
Schüler, Emil
Beddar, Sam
author_facet Thrower, Sara
Prajapati, Surendra
Holmes, Shannon
Schüler, Emil
Beddar, Sam
author_sort Thrower, Sara
collection PubMed
description (1) Background: The Exradin W2 is a commercially available scintillator detector designed for reference and relative dosimetry in small fields. In this work, we investigated the performance of the W2 scintillator in a 10 MV flattening-filter-free photon beam and compared it to the performance of ion chambers designed for small field measurements. (2) Methods: We measured beam profiles and percent depth dose curves with each detector and investigated the linearity of each system based on dose per pulse (DPP) and pulse repetition frequency. (3) Results: We found excellent agreement between the W2 scintillator and the ion chambers for beam profiles and percent depth dose curves. Our results also showed that the two-voltage method of calculating the ion recombination correction factor was sufficient to correct for the ion recombination effect of ion chambers, even at the highest DPP. (4) Conclusions: These findings show that the W2 scintillator shows excellent agreement with ion chambers in high DPP conditions.
format Online
Article
Text
id pubmed-9505273
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-95052732022-09-24 Characterization of the Plastic Scintillator Detector System Exradin W2 in a High Dose Rate Flattening-Filter-Free Photon Beam Thrower, Sara Prajapati, Surendra Holmes, Shannon Schüler, Emil Beddar, Sam Sensors (Basel) Article (1) Background: The Exradin W2 is a commercially available scintillator detector designed for reference and relative dosimetry in small fields. In this work, we investigated the performance of the W2 scintillator in a 10 MV flattening-filter-free photon beam and compared it to the performance of ion chambers designed for small field measurements. (2) Methods: We measured beam profiles and percent depth dose curves with each detector and investigated the linearity of each system based on dose per pulse (DPP) and pulse repetition frequency. (3) Results: We found excellent agreement between the W2 scintillator and the ion chambers for beam profiles and percent depth dose curves. Our results also showed that the two-voltage method of calculating the ion recombination correction factor was sufficient to correct for the ion recombination effect of ion chambers, even at the highest DPP. (4) Conclusions: These findings show that the W2 scintillator shows excellent agreement with ion chambers in high DPP conditions. MDPI 2022-09-08 /pmc/articles/PMC9505273/ /pubmed/36146135 http://dx.doi.org/10.3390/s22186785 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Thrower, Sara
Prajapati, Surendra
Holmes, Shannon
Schüler, Emil
Beddar, Sam
Characterization of the Plastic Scintillator Detector System Exradin W2 in a High Dose Rate Flattening-Filter-Free Photon Beam
title Characterization of the Plastic Scintillator Detector System Exradin W2 in a High Dose Rate Flattening-Filter-Free Photon Beam
title_full Characterization of the Plastic Scintillator Detector System Exradin W2 in a High Dose Rate Flattening-Filter-Free Photon Beam
title_fullStr Characterization of the Plastic Scintillator Detector System Exradin W2 in a High Dose Rate Flattening-Filter-Free Photon Beam
title_full_unstemmed Characterization of the Plastic Scintillator Detector System Exradin W2 in a High Dose Rate Flattening-Filter-Free Photon Beam
title_short Characterization of the Plastic Scintillator Detector System Exradin W2 in a High Dose Rate Flattening-Filter-Free Photon Beam
title_sort characterization of the plastic scintillator detector system exradin w2 in a high dose rate flattening-filter-free photon beam
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9505273/
https://www.ncbi.nlm.nih.gov/pubmed/36146135
http://dx.doi.org/10.3390/s22186785
work_keys_str_mv AT throwersara characterizationoftheplasticscintillatordetectorsystemexradinw2inahighdoserateflatteningfilterfreephotonbeam
AT prajapatisurendra characterizationoftheplasticscintillatordetectorsystemexradinw2inahighdoserateflatteningfilterfreephotonbeam
AT holmesshannon characterizationoftheplasticscintillatordetectorsystemexradinw2inahighdoserateflatteningfilterfreephotonbeam
AT schuleremil characterizationoftheplasticscintillatordetectorsystemexradinw2inahighdoserateflatteningfilterfreephotonbeam
AT beddarsam characterizationoftheplasticscintillatordetectorsystemexradinw2inahighdoserateflatteningfilterfreephotonbeam