Cargando…
Characterization of the Plastic Scintillator Detector System Exradin W2 in a High Dose Rate Flattening-Filter-Free Photon Beam
(1) Background: The Exradin W2 is a commercially available scintillator detector designed for reference and relative dosimetry in small fields. In this work, we investigated the performance of the W2 scintillator in a 10 MV flattening-filter-free photon beam and compared it to the performance of ion...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9505273/ https://www.ncbi.nlm.nih.gov/pubmed/36146135 http://dx.doi.org/10.3390/s22186785 |
_version_ | 1784796431143403520 |
---|---|
author | Thrower, Sara Prajapati, Surendra Holmes, Shannon Schüler, Emil Beddar, Sam |
author_facet | Thrower, Sara Prajapati, Surendra Holmes, Shannon Schüler, Emil Beddar, Sam |
author_sort | Thrower, Sara |
collection | PubMed |
description | (1) Background: The Exradin W2 is a commercially available scintillator detector designed for reference and relative dosimetry in small fields. In this work, we investigated the performance of the W2 scintillator in a 10 MV flattening-filter-free photon beam and compared it to the performance of ion chambers designed for small field measurements. (2) Methods: We measured beam profiles and percent depth dose curves with each detector and investigated the linearity of each system based on dose per pulse (DPP) and pulse repetition frequency. (3) Results: We found excellent agreement between the W2 scintillator and the ion chambers for beam profiles and percent depth dose curves. Our results also showed that the two-voltage method of calculating the ion recombination correction factor was sufficient to correct for the ion recombination effect of ion chambers, even at the highest DPP. (4) Conclusions: These findings show that the W2 scintillator shows excellent agreement with ion chambers in high DPP conditions. |
format | Online Article Text |
id | pubmed-9505273 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-95052732022-09-24 Characterization of the Plastic Scintillator Detector System Exradin W2 in a High Dose Rate Flattening-Filter-Free Photon Beam Thrower, Sara Prajapati, Surendra Holmes, Shannon Schüler, Emil Beddar, Sam Sensors (Basel) Article (1) Background: The Exradin W2 is a commercially available scintillator detector designed for reference and relative dosimetry in small fields. In this work, we investigated the performance of the W2 scintillator in a 10 MV flattening-filter-free photon beam and compared it to the performance of ion chambers designed for small field measurements. (2) Methods: We measured beam profiles and percent depth dose curves with each detector and investigated the linearity of each system based on dose per pulse (DPP) and pulse repetition frequency. (3) Results: We found excellent agreement between the W2 scintillator and the ion chambers for beam profiles and percent depth dose curves. Our results also showed that the two-voltage method of calculating the ion recombination correction factor was sufficient to correct for the ion recombination effect of ion chambers, even at the highest DPP. (4) Conclusions: These findings show that the W2 scintillator shows excellent agreement with ion chambers in high DPP conditions. MDPI 2022-09-08 /pmc/articles/PMC9505273/ /pubmed/36146135 http://dx.doi.org/10.3390/s22186785 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Thrower, Sara Prajapati, Surendra Holmes, Shannon Schüler, Emil Beddar, Sam Characterization of the Plastic Scintillator Detector System Exradin W2 in a High Dose Rate Flattening-Filter-Free Photon Beam |
title | Characterization of the Plastic Scintillator Detector System Exradin W2 in a High Dose Rate Flattening-Filter-Free Photon Beam |
title_full | Characterization of the Plastic Scintillator Detector System Exradin W2 in a High Dose Rate Flattening-Filter-Free Photon Beam |
title_fullStr | Characterization of the Plastic Scintillator Detector System Exradin W2 in a High Dose Rate Flattening-Filter-Free Photon Beam |
title_full_unstemmed | Characterization of the Plastic Scintillator Detector System Exradin W2 in a High Dose Rate Flattening-Filter-Free Photon Beam |
title_short | Characterization of the Plastic Scintillator Detector System Exradin W2 in a High Dose Rate Flattening-Filter-Free Photon Beam |
title_sort | characterization of the plastic scintillator detector system exradin w2 in a high dose rate flattening-filter-free photon beam |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9505273/ https://www.ncbi.nlm.nih.gov/pubmed/36146135 http://dx.doi.org/10.3390/s22186785 |
work_keys_str_mv | AT throwersara characterizationoftheplasticscintillatordetectorsystemexradinw2inahighdoserateflatteningfilterfreephotonbeam AT prajapatisurendra characterizationoftheplasticscintillatordetectorsystemexradinw2inahighdoserateflatteningfilterfreephotonbeam AT holmesshannon characterizationoftheplasticscintillatordetectorsystemexradinw2inahighdoserateflatteningfilterfreephotonbeam AT schuleremil characterizationoftheplasticscintillatordetectorsystemexradinw2inahighdoserateflatteningfilterfreephotonbeam AT beddarsam characterizationoftheplasticscintillatordetectorsystemexradinw2inahighdoserateflatteningfilterfreephotonbeam |