Cargando…

Ultra-High-Sensitivity, Miniaturized Fabry-Perot Interferometric Fiber-Optic Microphone for Weak Acoustic Signals Detection

An ultra-high-sensitivity, miniaturized Fabry-Perot interferometric (FPI) fiber-optic microphone (FOM) has been developed, utilizing a silicon cantilever as an acoustic transducer. The volumes of the cavity and the FOM are determined to be 60 microliters and 102 cubic millimeters, respectively. The...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Guojie, Li, Haie, Ye, Hongxin, Gong, Zhenfeng, Ma, Junsheng, Guo, Min, Chen, Ke, Peng, Wei, Yu, Qingxu, Mei, Liang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9505396/
https://www.ncbi.nlm.nih.gov/pubmed/36146295
http://dx.doi.org/10.3390/s22186948
_version_ 1784796462156087296
author Wu, Guojie
Li, Haie
Ye, Hongxin
Gong, Zhenfeng
Ma, Junsheng
Guo, Min
Chen, Ke
Peng, Wei
Yu, Qingxu
Mei, Liang
author_facet Wu, Guojie
Li, Haie
Ye, Hongxin
Gong, Zhenfeng
Ma, Junsheng
Guo, Min
Chen, Ke
Peng, Wei
Yu, Qingxu
Mei, Liang
author_sort Wu, Guojie
collection PubMed
description An ultra-high-sensitivity, miniaturized Fabry-Perot interferometric (FPI) fiber-optic microphone (FOM) has been developed, utilizing a silicon cantilever as an acoustic transducer. The volumes of the cavity and the FOM are determined to be 60 microliters and 102 cubic millimeters, respectively. The FOM has acoustic pressure sensitivities of 1506 nm/Pa at 2500 Hz and 26,773 nm/Pa at 3233 Hz. The minimum detectable pressure (MDP) and signal-to-noise ratio (SNR) of the designed FOM are 0.93 μPa/Hz(1/2) and 70.14 dB, respectively, at an acoustic pressure of 0.003 Pa. The designed FOM has the characteristics of ultra-high sensitivity, low MDP, and small size, which makes it suitable for the detection of weak acoustic signals, especially in the field of miniaturized all-optical photoacoustic spectroscopy.
format Online
Article
Text
id pubmed-9505396
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-95053962022-09-24 Ultra-High-Sensitivity, Miniaturized Fabry-Perot Interferometric Fiber-Optic Microphone for Weak Acoustic Signals Detection Wu, Guojie Li, Haie Ye, Hongxin Gong, Zhenfeng Ma, Junsheng Guo, Min Chen, Ke Peng, Wei Yu, Qingxu Mei, Liang Sensors (Basel) Article An ultra-high-sensitivity, miniaturized Fabry-Perot interferometric (FPI) fiber-optic microphone (FOM) has been developed, utilizing a silicon cantilever as an acoustic transducer. The volumes of the cavity and the FOM are determined to be 60 microliters and 102 cubic millimeters, respectively. The FOM has acoustic pressure sensitivities of 1506 nm/Pa at 2500 Hz and 26,773 nm/Pa at 3233 Hz. The minimum detectable pressure (MDP) and signal-to-noise ratio (SNR) of the designed FOM are 0.93 μPa/Hz(1/2) and 70.14 dB, respectively, at an acoustic pressure of 0.003 Pa. The designed FOM has the characteristics of ultra-high sensitivity, low MDP, and small size, which makes it suitable for the detection of weak acoustic signals, especially in the field of miniaturized all-optical photoacoustic spectroscopy. MDPI 2022-09-14 /pmc/articles/PMC9505396/ /pubmed/36146295 http://dx.doi.org/10.3390/s22186948 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wu, Guojie
Li, Haie
Ye, Hongxin
Gong, Zhenfeng
Ma, Junsheng
Guo, Min
Chen, Ke
Peng, Wei
Yu, Qingxu
Mei, Liang
Ultra-High-Sensitivity, Miniaturized Fabry-Perot Interferometric Fiber-Optic Microphone for Weak Acoustic Signals Detection
title Ultra-High-Sensitivity, Miniaturized Fabry-Perot Interferometric Fiber-Optic Microphone for Weak Acoustic Signals Detection
title_full Ultra-High-Sensitivity, Miniaturized Fabry-Perot Interferometric Fiber-Optic Microphone for Weak Acoustic Signals Detection
title_fullStr Ultra-High-Sensitivity, Miniaturized Fabry-Perot Interferometric Fiber-Optic Microphone for Weak Acoustic Signals Detection
title_full_unstemmed Ultra-High-Sensitivity, Miniaturized Fabry-Perot Interferometric Fiber-Optic Microphone for Weak Acoustic Signals Detection
title_short Ultra-High-Sensitivity, Miniaturized Fabry-Perot Interferometric Fiber-Optic Microphone for Weak Acoustic Signals Detection
title_sort ultra-high-sensitivity, miniaturized fabry-perot interferometric fiber-optic microphone for weak acoustic signals detection
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9505396/
https://www.ncbi.nlm.nih.gov/pubmed/36146295
http://dx.doi.org/10.3390/s22186948
work_keys_str_mv AT wuguojie ultrahighsensitivityminiaturizedfabryperotinterferometricfiberopticmicrophoneforweakacousticsignalsdetection
AT lihaie ultrahighsensitivityminiaturizedfabryperotinterferometricfiberopticmicrophoneforweakacousticsignalsdetection
AT yehongxin ultrahighsensitivityminiaturizedfabryperotinterferometricfiberopticmicrophoneforweakacousticsignalsdetection
AT gongzhenfeng ultrahighsensitivityminiaturizedfabryperotinterferometricfiberopticmicrophoneforweakacousticsignalsdetection
AT majunsheng ultrahighsensitivityminiaturizedfabryperotinterferometricfiberopticmicrophoneforweakacousticsignalsdetection
AT guomin ultrahighsensitivityminiaturizedfabryperotinterferometricfiberopticmicrophoneforweakacousticsignalsdetection
AT chenke ultrahighsensitivityminiaturizedfabryperotinterferometricfiberopticmicrophoneforweakacousticsignalsdetection
AT pengwei ultrahighsensitivityminiaturizedfabryperotinterferometricfiberopticmicrophoneforweakacousticsignalsdetection
AT yuqingxu ultrahighsensitivityminiaturizedfabryperotinterferometricfiberopticmicrophoneforweakacousticsignalsdetection
AT meiliang ultrahighsensitivityminiaturizedfabryperotinterferometricfiberopticmicrophoneforweakacousticsignalsdetection