Cargando…

Ultra-Sensitive Impedimetric Immunosensor Using Copper Oxide Quantum Dots Grafted on the Gold Microelectrode for the Detection of Parathion

The extensive use of organophosphates (OPs) pollutes the environment, leading to serious health hazards for human beings. The current need is to fabricate a sensing platform that will be sensitive and selective towards the detection of OPs at trace levels in the nM to fM range. With this discussed i...

Descripción completa

Detalles Bibliográficos
Autores principales: Nagabooshanam, Shalini, Talluri, Bhusankar, Thomas, Tiju, Krishnamurthy, Satheesh, Mathur, Ashish
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9505414/
https://www.ncbi.nlm.nih.gov/pubmed/36144008
http://dx.doi.org/10.3390/mi13091385
_version_ 1784796466839027712
author Nagabooshanam, Shalini
Talluri, Bhusankar
Thomas, Tiju
Krishnamurthy, Satheesh
Mathur, Ashish
author_facet Nagabooshanam, Shalini
Talluri, Bhusankar
Thomas, Tiju
Krishnamurthy, Satheesh
Mathur, Ashish
author_sort Nagabooshanam, Shalini
collection PubMed
description The extensive use of organophosphates (OPs) pollutes the environment, leading to serious health hazards for human beings. The current need is to fabricate a sensing platform that will be sensitive and selective towards the detection of OPs at trace levels in the nM to fM range. With this discussed in the present report, an ultra-sensitive immunosensing platform is developed using digestive-ripened copper oxide quantum dots grafted on a gold microelectrode (Au-µE) for the impedimetric detection of parathion (PT). The copper oxide quantum dots utilized in this study were of ultra-small size with a radius of approximately 2 to 3 nm and were monodispersed with readily available functional groups for the potential immobilization of antibody parathion (Anti-PT). The miniaturization is achieved by the utilization of Au-µE and the microfluidic platform utilized has the sample holding capacity of about 2 to 10 µL. The developed immunosensor provided a wide linear range of detection from 1 µM to 1 fM. The lower Limit of Detection (LoD) for the developed sensing platform was calculated to be 0.69 fM, with the sensitivity calculated to be 0.14 kΩ/nM/mm(2). The stability of the sensor was found to be ~40 days with good selectivity. The developed sensor has the potential to integrate with a portable device for field applications.
format Online
Article
Text
id pubmed-9505414
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-95054142022-09-24 Ultra-Sensitive Impedimetric Immunosensor Using Copper Oxide Quantum Dots Grafted on the Gold Microelectrode for the Detection of Parathion Nagabooshanam, Shalini Talluri, Bhusankar Thomas, Tiju Krishnamurthy, Satheesh Mathur, Ashish Micromachines (Basel) Article The extensive use of organophosphates (OPs) pollutes the environment, leading to serious health hazards for human beings. The current need is to fabricate a sensing platform that will be sensitive and selective towards the detection of OPs at trace levels in the nM to fM range. With this discussed in the present report, an ultra-sensitive immunosensing platform is developed using digestive-ripened copper oxide quantum dots grafted on a gold microelectrode (Au-µE) for the impedimetric detection of parathion (PT). The copper oxide quantum dots utilized in this study were of ultra-small size with a radius of approximately 2 to 3 nm and were monodispersed with readily available functional groups for the potential immobilization of antibody parathion (Anti-PT). The miniaturization is achieved by the utilization of Au-µE and the microfluidic platform utilized has the sample holding capacity of about 2 to 10 µL. The developed immunosensor provided a wide linear range of detection from 1 µM to 1 fM. The lower Limit of Detection (LoD) for the developed sensing platform was calculated to be 0.69 fM, with the sensitivity calculated to be 0.14 kΩ/nM/mm(2). The stability of the sensor was found to be ~40 days with good selectivity. The developed sensor has the potential to integrate with a portable device for field applications. MDPI 2022-08-25 /pmc/articles/PMC9505414/ /pubmed/36144008 http://dx.doi.org/10.3390/mi13091385 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Nagabooshanam, Shalini
Talluri, Bhusankar
Thomas, Tiju
Krishnamurthy, Satheesh
Mathur, Ashish
Ultra-Sensitive Impedimetric Immunosensor Using Copper Oxide Quantum Dots Grafted on the Gold Microelectrode for the Detection of Parathion
title Ultra-Sensitive Impedimetric Immunosensor Using Copper Oxide Quantum Dots Grafted on the Gold Microelectrode for the Detection of Parathion
title_full Ultra-Sensitive Impedimetric Immunosensor Using Copper Oxide Quantum Dots Grafted on the Gold Microelectrode for the Detection of Parathion
title_fullStr Ultra-Sensitive Impedimetric Immunosensor Using Copper Oxide Quantum Dots Grafted on the Gold Microelectrode for the Detection of Parathion
title_full_unstemmed Ultra-Sensitive Impedimetric Immunosensor Using Copper Oxide Quantum Dots Grafted on the Gold Microelectrode for the Detection of Parathion
title_short Ultra-Sensitive Impedimetric Immunosensor Using Copper Oxide Quantum Dots Grafted on the Gold Microelectrode for the Detection of Parathion
title_sort ultra-sensitive impedimetric immunosensor using copper oxide quantum dots grafted on the gold microelectrode for the detection of parathion
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9505414/
https://www.ncbi.nlm.nih.gov/pubmed/36144008
http://dx.doi.org/10.3390/mi13091385
work_keys_str_mv AT nagabooshanamshalini ultrasensitiveimpedimetricimmunosensorusingcopperoxidequantumdotsgraftedonthegoldmicroelectrodeforthedetectionofparathion
AT talluribhusankar ultrasensitiveimpedimetricimmunosensorusingcopperoxidequantumdotsgraftedonthegoldmicroelectrodeforthedetectionofparathion
AT thomastiju ultrasensitiveimpedimetricimmunosensorusingcopperoxidequantumdotsgraftedonthegoldmicroelectrodeforthedetectionofparathion
AT krishnamurthysatheesh ultrasensitiveimpedimetricimmunosensorusingcopperoxidequantumdotsgraftedonthegoldmicroelectrodeforthedetectionofparathion
AT mathurashish ultrasensitiveimpedimetricimmunosensorusingcopperoxidequantumdotsgraftedonthegoldmicroelectrodeforthedetectionofparathion