Retrospective Analysis for Dose Reduction to Organs at Risk with New Personalized Breast Holder (PERSBRA) in Left Breast IMRT
This study evaluated dose differences in normal organs at risk, such as the lungs, heart, left anterior descending artery (LAD), right coronary artery, left ventricle, and right breast under personalized breast holder (PERSBRA), when using intensity-modulated radiation therapy (IMRT). This study eva...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9505458/ https://www.ncbi.nlm.nih.gov/pubmed/36143153 http://dx.doi.org/10.3390/jpm12091368 |
_version_ | 1784796477642506240 |
---|---|
author | Chen, Chiu-Ping Chen, Tung-Ho Chiou, Jeng-Fong Chen, Yi-Ju Kuo, Chia-Chun Tseng, Kuo-Hsiung Chung, Meng-Yun Chen, Chun-You Wu, Jeng-You Lu, Long-Sheng Hsu, Shih-Ming |
author_facet | Chen, Chiu-Ping Chen, Tung-Ho Chiou, Jeng-Fong Chen, Yi-Ju Kuo, Chia-Chun Tseng, Kuo-Hsiung Chung, Meng-Yun Chen, Chun-You Wu, Jeng-You Lu, Long-Sheng Hsu, Shih-Ming |
author_sort | Chen, Chiu-Ping |
collection | PubMed |
description | This study evaluated dose differences in normal organs at risk, such as the lungs, heart, left anterior descending artery (LAD), right coronary artery, left ventricle, and right breast under personalized breast holder (PERSBRA), when using intensity-modulated radiation therapy (IMRT). This study evaluated the radiation protection offered by PERSBRA in left breast cancer radiation therapy. Here, we retrospectively collected data from 24 patients with left breast cancer who underwent breast-conserving surgery as well as IMRT radiotherapy. We compared the dose differences in target coverage and organs at risk with and without PERSBRA. For target coverage, tumor prescribed dose 95% coverage, conformity index, and homogeneity index were evaluated. For organs at risk, we compared the mean heart dose, mean left ventricle dose, LAD maximum and mean dose, mean left lung receiving 20 Gy, 10 Gy, and 5 Gy of left lung volume, maximum and mean coronary artery of the right, maximum of right breast, and mean dose. Good target coverage was achieved with and without PERSBRA. When PERSBRA was used with IMRT, the mean dose of the heart decreased by 42%, the maximum dose of LAD decreased by 26.4%, and the mean dose of LAD decreased by 47.0%. The mean dose of the left ventricle decreased by 54.1%, the volume (V(20)) of the left lung that received 20 Gy decreased by 22.8%, the volume (V(10)) of the left lung that received 10 Gy decreased by 19.8%, the volume (V(5)) of the left lung that received 5 Gy decreased by 15.7%, and the mean dose of the left lung decreased by 23.3%. Using PERSBRA with IMRT greatly decreases the dose to organs at risk (left lung, heart, left ventricle, and LAD). This study found that PERSBRA with IMRT can achieve results similar to deep inspiration breath-hold radiotherapy (DIBH) in terms of reducing the heart radiation dose and the risk of developing heart disease in patients with left breast cancer who cannot undergo DIBH. |
format | Online Article Text |
id | pubmed-9505458 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-95054582022-09-24 Retrospective Analysis for Dose Reduction to Organs at Risk with New Personalized Breast Holder (PERSBRA) in Left Breast IMRT Chen, Chiu-Ping Chen, Tung-Ho Chiou, Jeng-Fong Chen, Yi-Ju Kuo, Chia-Chun Tseng, Kuo-Hsiung Chung, Meng-Yun Chen, Chun-You Wu, Jeng-You Lu, Long-Sheng Hsu, Shih-Ming J Pers Med Article This study evaluated dose differences in normal organs at risk, such as the lungs, heart, left anterior descending artery (LAD), right coronary artery, left ventricle, and right breast under personalized breast holder (PERSBRA), when using intensity-modulated radiation therapy (IMRT). This study evaluated the radiation protection offered by PERSBRA in left breast cancer radiation therapy. Here, we retrospectively collected data from 24 patients with left breast cancer who underwent breast-conserving surgery as well as IMRT radiotherapy. We compared the dose differences in target coverage and organs at risk with and without PERSBRA. For target coverage, tumor prescribed dose 95% coverage, conformity index, and homogeneity index were evaluated. For organs at risk, we compared the mean heart dose, mean left ventricle dose, LAD maximum and mean dose, mean left lung receiving 20 Gy, 10 Gy, and 5 Gy of left lung volume, maximum and mean coronary artery of the right, maximum of right breast, and mean dose. Good target coverage was achieved with and without PERSBRA. When PERSBRA was used with IMRT, the mean dose of the heart decreased by 42%, the maximum dose of LAD decreased by 26.4%, and the mean dose of LAD decreased by 47.0%. The mean dose of the left ventricle decreased by 54.1%, the volume (V(20)) of the left lung that received 20 Gy decreased by 22.8%, the volume (V(10)) of the left lung that received 10 Gy decreased by 19.8%, the volume (V(5)) of the left lung that received 5 Gy decreased by 15.7%, and the mean dose of the left lung decreased by 23.3%. Using PERSBRA with IMRT greatly decreases the dose to organs at risk (left lung, heart, left ventricle, and LAD). This study found that PERSBRA with IMRT can achieve results similar to deep inspiration breath-hold radiotherapy (DIBH) in terms of reducing the heart radiation dose and the risk of developing heart disease in patients with left breast cancer who cannot undergo DIBH. MDPI 2022-08-25 /pmc/articles/PMC9505458/ /pubmed/36143153 http://dx.doi.org/10.3390/jpm12091368 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Chen, Chiu-Ping Chen, Tung-Ho Chiou, Jeng-Fong Chen, Yi-Ju Kuo, Chia-Chun Tseng, Kuo-Hsiung Chung, Meng-Yun Chen, Chun-You Wu, Jeng-You Lu, Long-Sheng Hsu, Shih-Ming Retrospective Analysis for Dose Reduction to Organs at Risk with New Personalized Breast Holder (PERSBRA) in Left Breast IMRT |
title | Retrospective Analysis for Dose Reduction to Organs at Risk with New Personalized Breast Holder (PERSBRA) in Left Breast IMRT |
title_full | Retrospective Analysis for Dose Reduction to Organs at Risk with New Personalized Breast Holder (PERSBRA) in Left Breast IMRT |
title_fullStr | Retrospective Analysis for Dose Reduction to Organs at Risk with New Personalized Breast Holder (PERSBRA) in Left Breast IMRT |
title_full_unstemmed | Retrospective Analysis for Dose Reduction to Organs at Risk with New Personalized Breast Holder (PERSBRA) in Left Breast IMRT |
title_short | Retrospective Analysis for Dose Reduction to Organs at Risk with New Personalized Breast Holder (PERSBRA) in Left Breast IMRT |
title_sort | retrospective analysis for dose reduction to organs at risk with new personalized breast holder (persbra) in left breast imrt |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9505458/ https://www.ncbi.nlm.nih.gov/pubmed/36143153 http://dx.doi.org/10.3390/jpm12091368 |
work_keys_str_mv | AT chenchiuping retrospectiveanalysisfordosereductiontoorgansatriskwithnewpersonalizedbreastholderpersbrainleftbreastimrt AT chentungho retrospectiveanalysisfordosereductiontoorgansatriskwithnewpersonalizedbreastholderpersbrainleftbreastimrt AT chioujengfong retrospectiveanalysisfordosereductiontoorgansatriskwithnewpersonalizedbreastholderpersbrainleftbreastimrt AT chenyiju retrospectiveanalysisfordosereductiontoorgansatriskwithnewpersonalizedbreastholderpersbrainleftbreastimrt AT kuochiachun retrospectiveanalysisfordosereductiontoorgansatriskwithnewpersonalizedbreastholderpersbrainleftbreastimrt AT tsengkuohsiung retrospectiveanalysisfordosereductiontoorgansatriskwithnewpersonalizedbreastholderpersbrainleftbreastimrt AT chungmengyun retrospectiveanalysisfordosereductiontoorgansatriskwithnewpersonalizedbreastholderpersbrainleftbreastimrt AT chenchunyou retrospectiveanalysisfordosereductiontoorgansatriskwithnewpersonalizedbreastholderpersbrainleftbreastimrt AT wujengyou retrospectiveanalysisfordosereductiontoorgansatriskwithnewpersonalizedbreastholderpersbrainleftbreastimrt AT lulongsheng retrospectiveanalysisfordosereductiontoorgansatriskwithnewpersonalizedbreastholderpersbrainleftbreastimrt AT hsushihming retrospectiveanalysisfordosereductiontoorgansatriskwithnewpersonalizedbreastholderpersbrainleftbreastimrt |