Cargando…

Preliminary Design Analysis of Membrane Bioreactors Application in Treatment Sequences for Modernization of Wastewater Treatment Plants

By using modeling with the Capdetworks software package, the study examines the definition of the essential elements of operational expenses at wastewater treatment facilities with a capacity of 1 to 100 thousand cubic meters per day. Four different treatment sequences were examined in the study; th...

Descripción completa

Detalles Bibliográficos
Autor principal: Makisha, Nikolay
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9505671/
https://www.ncbi.nlm.nih.gov/pubmed/36135838
http://dx.doi.org/10.3390/membranes12090819
_version_ 1784796531133513728
author Makisha, Nikolay
author_facet Makisha, Nikolay
author_sort Makisha, Nikolay
collection PubMed
description By using modeling with the Capdetworks software package, the study examines the definition of the essential elements of operational expenses at wastewater treatment facilities with a capacity of 1 to 100 thousand cubic meters per day. Four different treatment sequences were examined in the study; the first three revealed a standard setup with an activated sludge reactor and secondary clarifier (operating under various operating conditions), and the fourth scheme combined an activated sludge reactor with a submerged membrane bioreactor for sludge separation. The values of concentrations of key pollutants common for urban wastewater before treatment as well as technological parameters of operation were utilized as initial data for calculations because it was crucial to obtain conclusions that could be applied at real facilities. For each of the four treatment sequences, values for pollutants concentrations in effluent wastewater and hydraulic retention time were obtained and analyzed. The expenses of operating biological treatment facilities and treatment facilities in general, as well as the specific cost of power for treating 1 m(3) of wastewater, were taken into account. Additionally, the price of purchasing membrane modules, which can be categorized as operational due to their replacement frequency of around every 7 to 10 years, was determined. The study’s findings demonstrated that the use of membrane technologies at the secondary treatment stage might significantly affect the rebuilding of wastewater treatment plants under conditions of increased capacity (flow rate) and constrained area for growth.
format Online
Article
Text
id pubmed-9505671
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-95056712022-09-24 Preliminary Design Analysis of Membrane Bioreactors Application in Treatment Sequences for Modernization of Wastewater Treatment Plants Makisha, Nikolay Membranes (Basel) Article By using modeling with the Capdetworks software package, the study examines the definition of the essential elements of operational expenses at wastewater treatment facilities with a capacity of 1 to 100 thousand cubic meters per day. Four different treatment sequences were examined in the study; the first three revealed a standard setup with an activated sludge reactor and secondary clarifier (operating under various operating conditions), and the fourth scheme combined an activated sludge reactor with a submerged membrane bioreactor for sludge separation. The values of concentrations of key pollutants common for urban wastewater before treatment as well as technological parameters of operation were utilized as initial data for calculations because it was crucial to obtain conclusions that could be applied at real facilities. For each of the four treatment sequences, values for pollutants concentrations in effluent wastewater and hydraulic retention time were obtained and analyzed. The expenses of operating biological treatment facilities and treatment facilities in general, as well as the specific cost of power for treating 1 m(3) of wastewater, were taken into account. Additionally, the price of purchasing membrane modules, which can be categorized as operational due to their replacement frequency of around every 7 to 10 years, was determined. The study’s findings demonstrated that the use of membrane technologies at the secondary treatment stage might significantly affect the rebuilding of wastewater treatment plants under conditions of increased capacity (flow rate) and constrained area for growth. MDPI 2022-08-23 /pmc/articles/PMC9505671/ /pubmed/36135838 http://dx.doi.org/10.3390/membranes12090819 Text en © 2022 by the author. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Makisha, Nikolay
Preliminary Design Analysis of Membrane Bioreactors Application in Treatment Sequences for Modernization of Wastewater Treatment Plants
title Preliminary Design Analysis of Membrane Bioreactors Application in Treatment Sequences for Modernization of Wastewater Treatment Plants
title_full Preliminary Design Analysis of Membrane Bioreactors Application in Treatment Sequences for Modernization of Wastewater Treatment Plants
title_fullStr Preliminary Design Analysis of Membrane Bioreactors Application in Treatment Sequences for Modernization of Wastewater Treatment Plants
title_full_unstemmed Preliminary Design Analysis of Membrane Bioreactors Application in Treatment Sequences for Modernization of Wastewater Treatment Plants
title_short Preliminary Design Analysis of Membrane Bioreactors Application in Treatment Sequences for Modernization of Wastewater Treatment Plants
title_sort preliminary design analysis of membrane bioreactors application in treatment sequences for modernization of wastewater treatment plants
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9505671/
https://www.ncbi.nlm.nih.gov/pubmed/36135838
http://dx.doi.org/10.3390/membranes12090819
work_keys_str_mv AT makishanikolay preliminarydesignanalysisofmembranebioreactorsapplicationintreatmentsequencesformodernizationofwastewatertreatmentplants