Cargando…
The Automatic Algorithm of the Auto-CPAP Device as a Tool for the Assessment of the Treatment Efficacy of CPAP in Patients with Moderate and Severe Obstructive Sleep Apnea Syndrome
Obstructive sleep apnea syndrome (OSAS) is a common sleep-related breathing disorder where precise treatment assessment is of high importance. We aimed to validate an automatic algorithm of the auto-CPAP device and reveal polygraph usefulness in the OSAS diagnosis and treatment of outpatients. One h...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9506198/ https://www.ncbi.nlm.nih.gov/pubmed/36143393 http://dx.doi.org/10.3390/life12091357 |
_version_ | 1784796663241506816 |
---|---|
author | Brajer-Luftmann, Beata Trafas, Tomasz Mardas, Marcin Stelmach-Mardas, Marta Batura-Gabryel, Halina Piorunek, Tomasz |
author_facet | Brajer-Luftmann, Beata Trafas, Tomasz Mardas, Marcin Stelmach-Mardas, Marta Batura-Gabryel, Halina Piorunek, Tomasz |
author_sort | Brajer-Luftmann, Beata |
collection | PubMed |
description | Obstructive sleep apnea syndrome (OSAS) is a common sleep-related breathing disorder where precise treatment assessment is of high importance. We aimed to validate an automatic algorithm of the auto-CPAP device and reveal polygraph usefulness in the OSAS diagnosis and treatment of outpatients. One hundred patients with moderate OSAS, severe OSAS, and excessive daytime sleepiness qualified for CPAP treatment were included. The study was conducted in three stages. The first stage included a minimum 6-hour polysomnographic examination to select moderate and severe OSAS. The second stage involved an auto-CPAP treatment lasting at least 4 h with simultaneous polygraph recording. The third stage was a titration of at least 4 h with auto-CPAP. The Apnea–Hypopnea Index (AHI) and oxygen desaturation index (ODI) were calculated under auto-CPAP treatment, simultaneously using polygraph (stage two), and as a result of treatment with auto-CPAP (stage three). The mean AHI was 40.0 ± 20.9 for OSAS. Auto-CPAP treatment was effective in 97.5%. The mean residual AHI was 8.6 ± 4.8; there was no significant difference between the AHI CPAP, and the AHI polygraph values were assessed with an accuracy of 3.94/h. The sensitivity and specificity of calculated cut point 8.2 event/hour were: 55% and 82%, respectively. The calculated AUC for the AHI CPAP parameter was 0.633. Presented data confirmed that the automatic algorithm of auto-CPAP is a good tool for the assessment of the treatment efficacy of CPAP in patients, i.e., home setting, with a moderate or severe stage OSAS-presented high sleepiness. |
format | Online Article Text |
id | pubmed-9506198 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-95061982022-09-24 The Automatic Algorithm of the Auto-CPAP Device as a Tool for the Assessment of the Treatment Efficacy of CPAP in Patients with Moderate and Severe Obstructive Sleep Apnea Syndrome Brajer-Luftmann, Beata Trafas, Tomasz Mardas, Marcin Stelmach-Mardas, Marta Batura-Gabryel, Halina Piorunek, Tomasz Life (Basel) Article Obstructive sleep apnea syndrome (OSAS) is a common sleep-related breathing disorder where precise treatment assessment is of high importance. We aimed to validate an automatic algorithm of the auto-CPAP device and reveal polygraph usefulness in the OSAS diagnosis and treatment of outpatients. One hundred patients with moderate OSAS, severe OSAS, and excessive daytime sleepiness qualified for CPAP treatment were included. The study was conducted in three stages. The first stage included a minimum 6-hour polysomnographic examination to select moderate and severe OSAS. The second stage involved an auto-CPAP treatment lasting at least 4 h with simultaneous polygraph recording. The third stage was a titration of at least 4 h with auto-CPAP. The Apnea–Hypopnea Index (AHI) and oxygen desaturation index (ODI) were calculated under auto-CPAP treatment, simultaneously using polygraph (stage two), and as a result of treatment with auto-CPAP (stage three). The mean AHI was 40.0 ± 20.9 for OSAS. Auto-CPAP treatment was effective in 97.5%. The mean residual AHI was 8.6 ± 4.8; there was no significant difference between the AHI CPAP, and the AHI polygraph values were assessed with an accuracy of 3.94/h. The sensitivity and specificity of calculated cut point 8.2 event/hour were: 55% and 82%, respectively. The calculated AUC for the AHI CPAP parameter was 0.633. Presented data confirmed that the automatic algorithm of auto-CPAP is a good tool for the assessment of the treatment efficacy of CPAP in patients, i.e., home setting, with a moderate or severe stage OSAS-presented high sleepiness. MDPI 2022-08-31 /pmc/articles/PMC9506198/ /pubmed/36143393 http://dx.doi.org/10.3390/life12091357 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Brajer-Luftmann, Beata Trafas, Tomasz Mardas, Marcin Stelmach-Mardas, Marta Batura-Gabryel, Halina Piorunek, Tomasz The Automatic Algorithm of the Auto-CPAP Device as a Tool for the Assessment of the Treatment Efficacy of CPAP in Patients with Moderate and Severe Obstructive Sleep Apnea Syndrome |
title | The Automatic Algorithm of the Auto-CPAP Device as a Tool for the Assessment of the Treatment Efficacy of CPAP in Patients with Moderate and Severe Obstructive Sleep Apnea Syndrome |
title_full | The Automatic Algorithm of the Auto-CPAP Device as a Tool for the Assessment of the Treatment Efficacy of CPAP in Patients with Moderate and Severe Obstructive Sleep Apnea Syndrome |
title_fullStr | The Automatic Algorithm of the Auto-CPAP Device as a Tool for the Assessment of the Treatment Efficacy of CPAP in Patients with Moderate and Severe Obstructive Sleep Apnea Syndrome |
title_full_unstemmed | The Automatic Algorithm of the Auto-CPAP Device as a Tool for the Assessment of the Treatment Efficacy of CPAP in Patients with Moderate and Severe Obstructive Sleep Apnea Syndrome |
title_short | The Automatic Algorithm of the Auto-CPAP Device as a Tool for the Assessment of the Treatment Efficacy of CPAP in Patients with Moderate and Severe Obstructive Sleep Apnea Syndrome |
title_sort | automatic algorithm of the auto-cpap device as a tool for the assessment of the treatment efficacy of cpap in patients with moderate and severe obstructive sleep apnea syndrome |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9506198/ https://www.ncbi.nlm.nih.gov/pubmed/36143393 http://dx.doi.org/10.3390/life12091357 |
work_keys_str_mv | AT brajerluftmannbeata theautomaticalgorithmoftheautocpapdeviceasatoolfortheassessmentofthetreatmentefficacyofcpapinpatientswithmoderateandsevereobstructivesleepapneasyndrome AT trafastomasz theautomaticalgorithmoftheautocpapdeviceasatoolfortheassessmentofthetreatmentefficacyofcpapinpatientswithmoderateandsevereobstructivesleepapneasyndrome AT mardasmarcin theautomaticalgorithmoftheautocpapdeviceasatoolfortheassessmentofthetreatmentefficacyofcpapinpatientswithmoderateandsevereobstructivesleepapneasyndrome AT stelmachmardasmarta theautomaticalgorithmoftheautocpapdeviceasatoolfortheassessmentofthetreatmentefficacyofcpapinpatientswithmoderateandsevereobstructivesleepapneasyndrome AT baturagabryelhalina theautomaticalgorithmoftheautocpapdeviceasatoolfortheassessmentofthetreatmentefficacyofcpapinpatientswithmoderateandsevereobstructivesleepapneasyndrome AT piorunektomasz theautomaticalgorithmoftheautocpapdeviceasatoolfortheassessmentofthetreatmentefficacyofcpapinpatientswithmoderateandsevereobstructivesleepapneasyndrome AT brajerluftmannbeata automaticalgorithmoftheautocpapdeviceasatoolfortheassessmentofthetreatmentefficacyofcpapinpatientswithmoderateandsevereobstructivesleepapneasyndrome AT trafastomasz automaticalgorithmoftheautocpapdeviceasatoolfortheassessmentofthetreatmentefficacyofcpapinpatientswithmoderateandsevereobstructivesleepapneasyndrome AT mardasmarcin automaticalgorithmoftheautocpapdeviceasatoolfortheassessmentofthetreatmentefficacyofcpapinpatientswithmoderateandsevereobstructivesleepapneasyndrome AT stelmachmardasmarta automaticalgorithmoftheautocpapdeviceasatoolfortheassessmentofthetreatmentefficacyofcpapinpatientswithmoderateandsevereobstructivesleepapneasyndrome AT baturagabryelhalina automaticalgorithmoftheautocpapdeviceasatoolfortheassessmentofthetreatmentefficacyofcpapinpatientswithmoderateandsevereobstructivesleepapneasyndrome AT piorunektomasz automaticalgorithmoftheautocpapdeviceasatoolfortheassessmentofthetreatmentefficacyofcpapinpatientswithmoderateandsevereobstructivesleepapneasyndrome |