Cargando…
Effectiveness of a Uniquely Designed Oral Appliance on Obstructive Sleep Apnea Control: A Pilot Study
Objectives Obstructive sleep apnea is an inflammatory, chronic, and evolutive disease often needing adequate treatment and follow-up. The oral appliance (OA) is an accepted alternative therapy for obstructive sleep apnea (OSA) control. Due to greater adherence, OA with mandibular advancement (OA (m...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Thieme Medical and Scientific Publishers Pvt. Ltd.
2022
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9507576/ https://www.ncbi.nlm.nih.gov/pubmed/35181870 http://dx.doi.org/10.1055/s-0041-1735933 |
_version_ | 1784796874844143616 |
---|---|
author | Barbosa, Denise Fernandes Meira e Cruz, Miguel Alves, Marcelo Corrêa Zancanella, Edilson Berzin, Fausto Júnior, Almiro José Machado |
author_facet | Barbosa, Denise Fernandes Meira e Cruz, Miguel Alves, Marcelo Corrêa Zancanella, Edilson Berzin, Fausto Júnior, Almiro José Machado |
author_sort | Barbosa, Denise Fernandes |
collection | PubMed |
description | Objectives Obstructive sleep apnea is an inflammatory, chronic, and evolutive disease often needing adequate treatment and follow-up. The oral appliance (OA) is an accepted alternative therapy for obstructive sleep apnea (OSA) control. Due to greater adherence, OA with mandibular advancement (OA (m) ) is being recommended treatment for patients who refuse or do not tolerate continuous positive airway pressure. The mode of action of OA (m) is to promote the advancement of the mandible or tongue with a subsequent increase in the tone of the pharyngeal muscles and the permeability of the upper airway, but most OA (m) use conventional models as reference, analogic, or digital, dissociating dental arches of the skull structures. Materials and Methods A retrospective longitudinal study of 33 OSA patient treated with a different OA (m) , that use Camper plane as reference with skull structures for dental arches disocclusion, where polysomnographic, cephalometric measures, and subjective data from questionnaires pre- and post-treatment were assessed and correlated. Descriptive analysis, correlated Chi-square tests, and basic statistics were used. Generalized linear mixed model for repeated measure and post hoc Tukey–Kramer test compares the variables pre- and post-treatment. Shapiro–Wilk test and Pearson's correlation coefficients were used. All statistical tests were set in 5% level of significance. Results Regarding polysomnography data, there was a significant association between apnea hypopnea index (AHI) with oxygen saturation, arousal index (AI) and the maximum heartbeats, and sleep improvement and health risk reduction. Additionally, from cephalometric data, it was found a significant association between the tongue posture with the soft palate, hioyd-C3 and, lower and posterior airway. When both parameters are correlated, there are a significant dependent association with hyoid bone position with AHI and AI. The limitation of this study was the two-dimensional image used without provide volumetric measurements, but this limitation was reduced with the follow-up polysomnography parameters. Conclusion In this pilot study, DIORS OA (m) as an uniquely designed device using Camper plane as a reference for disocclusion was effective in the control of OSA. |
format | Online Article Text |
id | pubmed-9507576 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Thieme Medical and Scientific Publishers Pvt. Ltd. |
record_format | MEDLINE/PubMed |
spelling | pubmed-95075762022-09-24 Effectiveness of a Uniquely Designed Oral Appliance on Obstructive Sleep Apnea Control: A Pilot Study Barbosa, Denise Fernandes Meira e Cruz, Miguel Alves, Marcelo Corrêa Zancanella, Edilson Berzin, Fausto Júnior, Almiro José Machado Eur J Dent Objectives Obstructive sleep apnea is an inflammatory, chronic, and evolutive disease often needing adequate treatment and follow-up. The oral appliance (OA) is an accepted alternative therapy for obstructive sleep apnea (OSA) control. Due to greater adherence, OA with mandibular advancement (OA (m) ) is being recommended treatment for patients who refuse or do not tolerate continuous positive airway pressure. The mode of action of OA (m) is to promote the advancement of the mandible or tongue with a subsequent increase in the tone of the pharyngeal muscles and the permeability of the upper airway, but most OA (m) use conventional models as reference, analogic, or digital, dissociating dental arches of the skull structures. Materials and Methods A retrospective longitudinal study of 33 OSA patient treated with a different OA (m) , that use Camper plane as reference with skull structures for dental arches disocclusion, where polysomnographic, cephalometric measures, and subjective data from questionnaires pre- and post-treatment were assessed and correlated. Descriptive analysis, correlated Chi-square tests, and basic statistics were used. Generalized linear mixed model for repeated measure and post hoc Tukey–Kramer test compares the variables pre- and post-treatment. Shapiro–Wilk test and Pearson's correlation coefficients were used. All statistical tests were set in 5% level of significance. Results Regarding polysomnography data, there was a significant association between apnea hypopnea index (AHI) with oxygen saturation, arousal index (AI) and the maximum heartbeats, and sleep improvement and health risk reduction. Additionally, from cephalometric data, it was found a significant association between the tongue posture with the soft palate, hioyd-C3 and, lower and posterior airway. When both parameters are correlated, there are a significant dependent association with hyoid bone position with AHI and AI. The limitation of this study was the two-dimensional image used without provide volumetric measurements, but this limitation was reduced with the follow-up polysomnography parameters. Conclusion In this pilot study, DIORS OA (m) as an uniquely designed device using Camper plane as a reference for disocclusion was effective in the control of OSA. Thieme Medical and Scientific Publishers Pvt. Ltd. 2022-02-18 /pmc/articles/PMC9507576/ /pubmed/35181870 http://dx.doi.org/10.1055/s-0041-1735933 Text en The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. ( https://creativecommons.org/licenses/by/4.0/ ) https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Barbosa, Denise Fernandes Meira e Cruz, Miguel Alves, Marcelo Corrêa Zancanella, Edilson Berzin, Fausto Júnior, Almiro José Machado Effectiveness of a Uniquely Designed Oral Appliance on Obstructive Sleep Apnea Control: A Pilot Study |
title | Effectiveness of a Uniquely Designed Oral Appliance on Obstructive Sleep Apnea Control: A Pilot Study |
title_full | Effectiveness of a Uniquely Designed Oral Appliance on Obstructive Sleep Apnea Control: A Pilot Study |
title_fullStr | Effectiveness of a Uniquely Designed Oral Appliance on Obstructive Sleep Apnea Control: A Pilot Study |
title_full_unstemmed | Effectiveness of a Uniquely Designed Oral Appliance on Obstructive Sleep Apnea Control: A Pilot Study |
title_short | Effectiveness of a Uniquely Designed Oral Appliance on Obstructive Sleep Apnea Control: A Pilot Study |
title_sort | effectiveness of a uniquely designed oral appliance on obstructive sleep apnea control: a pilot study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9507576/ https://www.ncbi.nlm.nih.gov/pubmed/35181870 http://dx.doi.org/10.1055/s-0041-1735933 |
work_keys_str_mv | AT barbosadenisefernandes effectivenessofauniquelydesignedoralapplianceonobstructivesleepapneacontrolapilotstudy AT meiraecruzmiguel effectivenessofauniquelydesignedoralapplianceonobstructivesleepapneacontrolapilotstudy AT alvesmarcelocorrea effectivenessofauniquelydesignedoralapplianceonobstructivesleepapneacontrolapilotstudy AT zancanellaedilson effectivenessofauniquelydesignedoralapplianceonobstructivesleepapneacontrolapilotstudy AT berzinfausto effectivenessofauniquelydesignedoralapplianceonobstructivesleepapneacontrolapilotstudy AT junioralmirojosemachado effectivenessofauniquelydesignedoralapplianceonobstructivesleepapneacontrolapilotstudy |