Manual wheelchair use leads to a series of failed shoulder replacements: A case report and literature review

Manual wheelchair users place high stress on their shoulders. We describe a 69‐year‐old male who developed end‐stage shoulder osteoarthritis from chronic manual wheelchair (MW) use. Three prosthetic total shoulder replacements failed, reflecting his refusal to transition to an electric wheelchair. M...

Descripción completa

Detalles Bibliográficos
Autores principales: Skedros, John G., Cronin, John T., Finlinson, Ethan D., Langston, Tanner D., Adondakis, Micheal G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9508804/
https://www.ncbi.nlm.nih.gov/pubmed/36188047
http://dx.doi.org/10.1002/ccr3.6374
Descripción
Sumario:Manual wheelchair users place high stress on their shoulders. We describe a 69‐year‐old male who developed end‐stage shoulder osteoarthritis from chronic manual wheelchair (MW) use. Three prosthetic total shoulder replacements failed, reflecting his refusal to transition to an electric wheelchair. MW use must be avoided in some of these patients.