Daily Variations of Corneal White-to-White Diameter Measured with Different Methods
PURPOSE: A precise determination of the corneal diameter is essential for the diagnosis of various ocular diseases, cataract and refractive surgery as well as for the selection and fitting of contact lenses. The aim of this study was to investigate the agreement between two automatic and one manual...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9509000/ https://www.ncbi.nlm.nih.gov/pubmed/36164584 http://dx.doi.org/10.2147/OPTO.S360651 |
_version_ | 1784797139399868416 |
---|---|
author | Bandlitz, Stefan Nakhoul, Makram Kotliar, Konstantin |
author_facet | Bandlitz, Stefan Nakhoul, Makram Kotliar, Konstantin |
author_sort | Bandlitz, Stefan |
collection | PubMed |
description | PURPOSE: A precise determination of the corneal diameter is essential for the diagnosis of various ocular diseases, cataract and refractive surgery as well as for the selection and fitting of contact lenses. The aim of this study was to investigate the agreement between two automatic and one manual method for corneal diameter determination and to evaluate possible diurnal variations in corneal diameter. PATIENTS AND METHODS: Horizontal white-to-white corneal diameter of 20 volunteers was measured at three different fixed times of a day with three methods: Scheimpflug method (Pentacam HR, Oculus), placido based topography (Keratograph 5M, Oculus) and manual method using an image analysis software at a slitlamp (BQ900, Haag-Streit). RESULTS: The two-factorial analysis of variance could not show a significant effect of the different instruments (p = 0.117), the different time points (p = 0.506) and the interaction between instrument and time point (p = 0.182). Very good repeatability (intraclass correlation coefficient ICC, quartile coefficient of dispersion QCD) was found for all three devices. However, manual slitlamp measurements showed a higher QCD than the automatic measurements with the Keratograph 5M and the Pentacam HR at all measurement times. CONCLUSION: The manual and automated methods used in the study to determine corneal diameter showed good agreement and repeatability. No significant diurnal variations of corneal diameter were observed during the period of time studied. |
format | Online Article Text |
id | pubmed-9509000 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-95090002022-09-25 Daily Variations of Corneal White-to-White Diameter Measured with Different Methods Bandlitz, Stefan Nakhoul, Makram Kotliar, Konstantin Clin Optom (Auckl) Original Research PURPOSE: A precise determination of the corneal diameter is essential for the diagnosis of various ocular diseases, cataract and refractive surgery as well as for the selection and fitting of contact lenses. The aim of this study was to investigate the agreement between two automatic and one manual method for corneal diameter determination and to evaluate possible diurnal variations in corneal diameter. PATIENTS AND METHODS: Horizontal white-to-white corneal diameter of 20 volunteers was measured at three different fixed times of a day with three methods: Scheimpflug method (Pentacam HR, Oculus), placido based topography (Keratograph 5M, Oculus) and manual method using an image analysis software at a slitlamp (BQ900, Haag-Streit). RESULTS: The two-factorial analysis of variance could not show a significant effect of the different instruments (p = 0.117), the different time points (p = 0.506) and the interaction between instrument and time point (p = 0.182). Very good repeatability (intraclass correlation coefficient ICC, quartile coefficient of dispersion QCD) was found for all three devices. However, manual slitlamp measurements showed a higher QCD than the automatic measurements with the Keratograph 5M and the Pentacam HR at all measurement times. CONCLUSION: The manual and automated methods used in the study to determine corneal diameter showed good agreement and repeatability. No significant diurnal variations of corneal diameter were observed during the period of time studied. Dove 2022-09-20 /pmc/articles/PMC9509000/ /pubmed/36164584 http://dx.doi.org/10.2147/OPTO.S360651 Text en © 2022 Bandlitz et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Original Research Bandlitz, Stefan Nakhoul, Makram Kotliar, Konstantin Daily Variations of Corneal White-to-White Diameter Measured with Different Methods |
title | Daily Variations of Corneal White-to-White Diameter Measured with Different Methods |
title_full | Daily Variations of Corneal White-to-White Diameter Measured with Different Methods |
title_fullStr | Daily Variations of Corneal White-to-White Diameter Measured with Different Methods |
title_full_unstemmed | Daily Variations of Corneal White-to-White Diameter Measured with Different Methods |
title_short | Daily Variations of Corneal White-to-White Diameter Measured with Different Methods |
title_sort | daily variations of corneal white-to-white diameter measured with different methods |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9509000/ https://www.ncbi.nlm.nih.gov/pubmed/36164584 http://dx.doi.org/10.2147/OPTO.S360651 |
work_keys_str_mv | AT bandlitzstefan dailyvariationsofcornealwhitetowhitediametermeasuredwithdifferentmethods AT nakhoulmakram dailyvariationsofcornealwhitetowhitediametermeasuredwithdifferentmethods AT kotliarkonstantin dailyvariationsofcornealwhitetowhitediametermeasuredwithdifferentmethods |